S13 200KVA 35KV oil-immersed transformer
Nov 07, 2025
Leave a message
The description of S13-200KVA / 35KV oil-immersed transformer
1. The iron core is made of high-quality cold-rolled silicon steel sheet which is tightened with steel drawstrings to form a solid frame structure with the clamps, which strengthens the iron core tightening force and effectively reduces the no-load loss, no-load current and noise of the transformer.
2. The S13-200KVA / 35KV oil-immersed transformer coil uses high-purity oxygen-free copper which effectively reduces the copper loss; the pads and stays are rounded, the electric field is uniform, and the reliability is enhanced. The inner winding support is strengthened, improving its stability and preventing instability deformation and improving the ability of the S13-200KVA / 35KV oil-immersed transformer to withstand short circuits.
3. Structure using ripple heat dissipation structure and oil storage tank to adjust oil level change. Economical, practical and beautiful.
S13-200KVA / 35KV oil-immersed transformer and above 1000Kva oil-immersed transformers must be equipped with outdoor signal thermometers and can be connected to remote signals. 800kVA oil-immersed transformers and above oil-immersed transformers should be equipped with gas relays and pressure protection devices. Oil-immersed transformers below 800kVA can also be equipped with gas relays according to the requirements of use. Dry-type transformers should be equipped with temperature measuring devices in accordance with the manufacturer's regulations, generally 630kVA and above power transformers.

200KVA oil type transformer Technical Specifications
| Rated Power | 200 kVA | |
| Rating Primary Voltage | 2.4 - 34.5kV | |
| Secondary Voltage | 480/277V 400/230V 380/220V Customized |
|
| Frequency | 50/60Hz | |
| Vector Group | Dyn11, Yyn0, Dyn5 | |
| Winding Material | Aluminum/Copper | |
| Efficiency | As IEEE, Doe 2016, CAS Std or Customized | |
| Impedance Voltage | Nominal 2% or Customized 1.1-5.75% | |
| Altitude | ≤1,000m or Customized | |
| Color | ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc | |
| Tank material | Mild Steel, 304 Stainless Steel | |
| Insulating Oil Weight | 305 kg | |
| Total Weight | 1350 kg | |
| Outline Dimensions(L×W×H)in. | 1455 × 1050 × 1580(mm) | |
The advantages of S13-200KVA / 35KV oil-filled transformer
S13-200KVA / 35KV oil-immersed transformer adopts full oil-filled sealed type. The corrugated oil tank housing is a hermetically sealed oil tank with its elasticity adapted to the expansion of oil. S13-200KVA / 35KV oil-immersed transformer have been widely used in various power distribution equipment.
The features of S13-200KVA / 35KV oil-filled transformer
1. In addition to the low-capacity windings of S13-200KVA / 35KV oil-immersed transformer using copper conductors. The oil-immersed transformers generally use a copper foil-wound cylindrical structure. High-voltage windings use a multilayer cylindrical structure to make the winding's amps balanced and magnetic leakage small. High mechanical strength and strong short circuit resistance.
2. The iron core and windings of S13-200KVA / 35KV oil-immersed transformer are each tightened. The fastening parts such as the height of the device and the low-voltage leads are equipped with self-locking lock nuts. The structure is unsuspended and can withstand the shock of transportation.
3. The coil and iron core are vacuum-dried and the oil-immersed transformer oil is vacuum-filtered and oil-filled to reduce the moisture inside the oil-immersed transformer to a lower level.
4. The oil tank of S13-200KVA / 35KV oil-immersed transformer uses a corrugated sheet, which has a breathing function to compensate for the volume change of oil caused by temperature changes. Therefore, this product does not have an oil storage tank which obviously reduces the height of the oil-immersed transformer.
5. As the corrugated sheet replaces the oil storage tank and isolates the transformer oil from the outside world, this effectively prevents the entry of oxygen and moisture and reduces the insulation performance.
company profile
GNEE New Material has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE New Material Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE New Material Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji