Oil Immersed Power Transformers
Nov 07, 2025
Leave a message
The Principle of the Power Transformer
After the primary winding of the power transformer is connected to the AC power supply, an alternating current flows through the winding to generate magnetic flux, establishing alternating magnetic flux in the iron core. The electrical energy is drawn into the core as magnetic energy, and the flux links both the primary and secondary windings. Due to electromagnetic induction, induced electromotive forces with the same frequency are generated in the primary and secondary windings. If the secondary winding is connected to a load, a current flows through the load under the induced EMF, and the magnetic energy in the core is converted into electrical energy again. This is how power transformers use electromagnetic induction to transfer power from the supply to the load.
Product Parameters
| Item | Detail |
|---|---|
| Product description | Oil immersed transformer |
| Reference standard | IEC 60076 |
| Capacity | 50-2500 kVA or customized |
| Frequency | 50/60 Hz |
| Voltage (HV) | 22 kV or customized |
| Voltage (LV) | 0.4 kV or customized |
| Impedance | 4% |
| Vector group | Dyn11 |
| Tapping range | plus/minus 2 x 2.5% |
| Core material | Silicon steel |
| Winding material | Aluminum or copper |
| Temperature rise | Per IEC (winding temperature rise typically 65 K for oil-immersed units) |
| Cooling method | ONAN / ONAF |
The Classifications of Power Transformers
1. Function: power transformers are divided into step-up transformers and step-down transformers. Step-down transformers are used in factory substations; the step-down transformer of a terminal substation is also called a distribution transformer.
2. Capacity: power transformers are divided into capacity series, including the R8 and R10 series. The R8 series increases capacity by about 1.33 times per step (for example 100, 135, 180, 240, 320, 420, 560, 750, 1000 kVA); the R10 series increases by about 1.26 times per step (100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000 kVA) and is recommended by IEC for rational selection.
3. Number of phases: single-phase and three-phase; factory substations usually use three-phase power transformers.
4. Voltage regulation method: off-circuit (non-excited) regulation and on-load regulation; most factory substations use off-circuit regulating transformers.
5. Winding structure: single-winding autotransformer, double-winding transformer, and triple-winding transformer; most factory substations use double-winding transformers.
6. Insulation and cooling methods: oil-immersed, dry, and gas-filled (SF6) types. Oil-immersed transformers include oil-immersed self-cooling, oil-immersed air-cooled, oil-immersed water-cooled, and forced oil circulation cooling; factory substations mostly use oil-immersed self-cooled transformers. A gas-filled transformer has its core and windings in a casing filled with insulating gas.
7. Winding conductor material: copper winding and aluminum winding transformers; low-loss copper winding transformers are now more widely used.
Applications
Power generation and transmission: power plants step up generator voltage for efficient transmission; substations regulate voltage for grid distribution; transmission networks connect different parts of the high-voltage grid.
Industrial and commercial sectors: industrial facilities receive continuous stable power for heavy machinery; commercial buildings receive reliable power; the oil and gas industry uses robust high-capacity units on offshore platforms and refineries.
Renewable energy: solar and wind farms integrate generated power into the grid by stepping up voltage; collector systems manage power efficiently.
Transportation: electrified railway systems use transformers for train power supply.
Frequently Asked Questions
Q: How does a transformer work? A> By electromagnetic induction: alternating flux in the core links both windings and transfers power between them.
Q: What capacity range is available? A> 50-2500 kVA or customized.
Q: What are the R8 and R10 series? A> Two standard capacity progressions; R10 is recommended by IEC.
Q: What cooling methods exist? A> Oil-immersed self-cooling (ONAN), air-cooled (ONAF), water-cooled, and forced oil circulation.
Q: What winding materials are used? A> Aluminum or copper; copper gives lower losses.
Q: Where are oil immersed transformers used? A> Power plants, substations, industry, renewable energy, and railway systems.
Need an oil immersed power transformer? Contact us with capacity, voltage, and standard requirements for a quotation.