Nanocrystalline Toroidal Cores for High-Power High-Frequency Transformers

Sep 24, 2025

Leave a message

Why a Toroid Suits High-Power, High-Frequency Duty

A toroidal core closes the magnetic path inside the winding, so almost all of the flux is linked by the turns and leakage is small. The distributed, gapless structure also avoids the concentrated loss of an air gap, and the winding can be spread evenly around the ring to keep the magnetising force uniform. At the same time the ribbon is wound from very thin strip, about 20 micrometres, which suppresses eddy-current loss in the core material itself. The combination is what makes a wound nanocrystalline ring practical at power levels where a ferrite core would need a much larger volume. Because the structure is nanocrystalline, with grains below about 10 nanometres, permeability is high and magnetostriction is close to zero, so acoustic noise and mechanical stress sensitivity remain low.

Core Loss and Frequency Behaviour

Loss in the core rises with frequency and with flux swing, but because the ribbon is thin the rise is gradual compared with laminated sheet steel. Designers normally work from a loss-versus-frequency curve for the specific material class and stay well inside the thermal limit of the insulation system. The usual applications share a common requirement: a rectangular or near-rectangular flux swing at a switching frequency in the kilohertz range, with a low magnetising current, so that the converter operates with a small core and a short winding. Typical duty includes inverter welding equipment, X-ray and laser supplies, uninterruptible and communication power supplies, induction heating inverters, variable-speed motor drives and plasma cutting machines.

Standard Toroidal Sizes, Weight and Case Data

Rings are supplied either as bare wound cores or in a protective case, most commonly a glass-filled thermoplastic case rated for continuous service around 130 C. The finished size is slightly larger than the magnetic core because of the case wall and any internal padding.

Core size OD x ID x H (mm) Finished core size (mm) Approximate core weight (g) Nominal permeability at 10 kHz Case
50 x 32 x 20 54 x 28 x 24 125 about 87,000 thermoplastic
64 x 40 x 20 66 x 37 x 23 215 about 97,000 thermoplastic
70 x 40 x 25 72 x 37 x 28 352 about 94,000 thermoplastic
100 x 50 x 25 105 x 45 x 44 805 about 97,000 thermoplastic
105 x 60 x 30 110 x 57 x 35 957 about 96,000 thermoplastic

The inductance factor, normally quoted as AL at 10 kHz, depends on the permeability class actually delivered, so the AL value on the certificate should be measured on the batch rather than assumed from the table. Saturation current similarly follows from the flux density limit, the cross-section and the number of turns, and should be quoted for the finished winding, not the bare core.

Insulation, Potting and Temperature Class

The ribbon is thin and brittle after crystallisation, so the core must be protected against winding tension and edge damage. Cased cores are common for that reason, and where the winding is wound directly onto a coated core the designer should specify the coating thickness and its dielectric withstand. Potting and impregnation resins must be compatible with the service temperature, and cure schedules must be chosen so that the assembly is not overheated. A useful rule is to treat the case and coating as the limiting element: the magnetic alloy tolerates higher temperature than most organic insulation, so the declared temperature class normally belongs to the insulation system.

Test and Acceptance Criteria

Ring cores are measured as ring specimens, which is the configuration addressed by IEC 60404-6 for soft magnetic materials in the frequency range from 20 Hz to 200 kHz. A delivery specification should state the measuring frequency, the flux density or magnetising force at which permeability is quoted, the accepted tolerance band and the maximum loss. Wound components are then accepted on inductance, impedance, dielectric strength and temperature rise in the application. For current transformer duty, type and routine tests follow IEC 61869-2, including ratio and phase error checks at the specified burden.

Frequently Asked Questions

Q: What is the advantage of a toroidal core over a gapped core in a high-power converter?
A: The closed path has no deliberate gap, so magnetising current is low and there is no fringing flux around a gap to cause local winding loss; the trade-off is a lower saturation margin at high bias current.

Q: At which frequencies are nanocrystalline rings normally designed?
A: From a few kilohertz to about 80 kHz for power conversion, with common mode chokes extending to higher frequency and current sensors operating at mains frequency with harmonics.

Q: Why does the finished size differ from the core size?
A: The protective case and any padding add wall thickness, typically a few millimetres on the outside diameter and inner diameter, and the case height is quoted separately.

Q: How is the AL value checked?
A: By measuring inductance on a wound specimen at the declared frequency and test signal, then dividing by the square of the turn count, in line with the ring specimen method of IEC 60404-6.

Q: Can a cased ring be wound with heavy copper?
A: It can, but the winding tension and bend radius must respect the case material, and the fill factor must leave room for insulation and for the temperature rise of the winding.

Q: What temperature should be declared on the datasheet?
A: The temperature class of the insulation system, because the case, coating and impregnating resin reach their limits before the magnetic alloy does.

Send Inquiry