Nanocrystalline Split Core and Gapped Cut Cores for Current Sensors

Sep 24, 2025

Leave a message

What a Split Core Does That a Closed Ring Cannot

A closed toroid must be threaded over the conductor before the circuit is assembled. A split core is cut into two or more segments so that it can be opened, placed around an existing cable or busbar and closed again, which is essential for retrofitting metering, for temporary measurement during commissioning and for equipment that must stay energised. The magnetic penalty is real: every cut introduces an interface that the flux must cross, and the effective permeability of the assembly falls. Well-made cut cores still reach a permeability of 60,000 or above after cutting, which is why the technique is practical for measurement-grade sensors rather than only for indication.

Cutting, Permeability Loss and Gap Control

Cutting is a mechanical operation on ribbon about 20 micrometres thick, stacked and bonded into a block. The quality of the cut face determines how much of the original permeability survives: a rough, oxidised or burred face behaves like a larger air gap, and any metal bridging across the cut creates a short circuit that destroys the permeability entirely. Two further effects must be managed. First, the bonding resin must be chosen so that it does not smear into the interface. Second, where a deliberate air gap is required, for example to improve linearity or to allow a defined bias current, the gap must be set by precisely ground spacers, because gap length dominates the inductance factor and the saturation behaviour. After assembly, a gapped core is characterised by a stable AL value and a much more linear response to primary current than a high-permeability closed core, at the cost of lower sensitivity.

Dimensional Tolerances and Mating Faces

Tolerance control matters more in a split core than in a solid one, because both the outside diameter and the height difference between the mating halves affect the gap that appears when the core is closed. Typical production tolerances are shown below.

Outside diameter range (mm) Dimensional tolerance (mm) Height difference between halves (mm)
OD up to 20 plus or minus 0.3 0.3 or less
20 < OD up to 50 plus or minus 1.0 1.0 or less
50 < OD up to 80 plus or minus 1.5 2.0 or less
80 < OD up to 120 plus or minus 3.0 3.0 or less
120 < OD up to 160 plus or minus 5.0 4.0 or less
OD above 160 as agreed for the application as agreed for the application

The clamping arrangement is part of the core specification. A consistent closing force is needed so that the halves register repeatedly, and the enclosure that holds the two parts together must resist the force exerted by the current-carrying winding and the cable. Where the sensor is portable, repeated opening and closing cycles are a wear mechanism, and the hinge and latch should be evaluated over the expected number of cycles.

Accuracy Classes and Application Fit

Split cores are most often used for measuring current transformers, a family covered by IEC 61869-2, which defines the accuracy classes and the error limits at rated burden. Class 0.5, 1 and 3 are common for indication and sub-metering, class 0.2 or 0.2S for billing, and protection classes such as 5P or 10P are specified with an accuracy limit factor that states how many times rated current the core must still transform within a defined composite error. A split core with a high-permeability, uncut design is chosen for the low-current accuracy points; a deliberately gapped core is chosen where the primary current is large, unidirectional or rich in harmonics, because the gap linearises the magnetisation curve and prevents the core from saturating. Hysteresis loop shape should therefore be selected together with the class, not afterwards.

Frequently Asked Questions

Q: How much permeability is lost when a core is cut?
A: It depends on the cut face quality and the closing force, but a properly processed nanocrystalline cut core typically retains a permeability of 60,000 or above, which is sufficient for measuring duty.

Q: When is a gapped core preferable to a closed core?
A: When the primary current is high, unidirectional or distorted, or when the sensor must stay linear over a wide range; the gap reduces permeability but stabilises the response.

Q: Why is height difference between the halves specified?
A: Because any mismatch opens an additional air gap when the core is closed, which lowers the inductance factor and increases error well beyond what the nominal dimensions suggest.

Q: Can a split core be used for billing-grade metering?
A: Yes, when it is built to a class defined in IEC 61869-2, tested at the rated burden, and the repeatability of the clamping mechanism over many opening cycles is demonstrated.

Q: What happens if metal debris bridges the cut faces?
A: The short circuit across the cut destroys the effective permeability and the core behaves like a shorted turn, so the sensor readings become unusable. Cut faces must be kept clean and unburred.

Q: Does the gap change the temperature behaviour?
A: A gapped core has lower sensitivity to permeability drift with temperature, which is an advantage, but the inductance factor must be quoted at a stated temperature for the design to hold.

Send Inquiry