100 KVA 11KV Oil Immersed Distribution Transformer

Nov 10, 2025

Leave a message

info-369-351

The rated power of the oil transformer is 100 KVA. It is a Step-down transformer 11KV to 0.38KV, the primary voltage is 11KV, the secondary is 0.38KV. The transformer is equipped with ±2*2.5% no load tap changer at primary side. Our 100 KVA Distribution Transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.

Technical Specification

100 KVA Oil Immersed Distribution Transformer to Guatemala

Model

S11-100 KVA-11/0.38KV

Type

Oil Immersed Distribution Transformer

Standard

IEC60076

Rated Power

100 KVA

Frequency

60 HZ

Phase

Three

Cooling Type

ONAN

Primary Voltage

11 KV

Secondary Voltage

0.38 KV

Winding Material

Copper

Vector Group

Dyn11

Impedance

4%

Tap Changer

NLTC

Tapping Range

±2*2.5%

No Load Loss

0.5kw

On Load Loss

1.5kw

Accessories

Standard Configuration

Remarks

N/A

 

 

100 KVA 11KV Oil Filled Transformer applications

  • Residential and commercial: Powering apartment buildings, shopping centers, office buildings, and hotels.
  • Industrial: Providing power to small factories and other industrial sites.
  • Utility: Used within power distribution substations to regulate electricity before it reaches consumers.
  • Infrastructure: Found in large infrastructure projects such as airports and hospitals.
  • Specific projects: Utilized in various other projects, including water treatment plants and mining operations.

 

 

Main Component of 100 KVA 11/0.38KV Transformer

Core:

The iron core is one of the most basic components of the transformer, and it is the magnetic circuit part of the transformer. The primary and secondary winding of the transformer are all on the iron core. In order to improve the magnetic permeability of the magnetic circuit and reduce the eddy current loss in the iron core, the iron core is usually made of 0.35mm silicon steel sheet with insulating surface. The iron core consists of two parts, the iron core column and the iron yoke. The winding are put on the iron core column, and the iron yoke connects the iron core to form a closed magnetic circuit.

 

Winding:

The winding is also one of the most basic parts of the transformer. It is the circuit part of a transformer, usually made of copper or aluminum wire wrapped in insulating paper. The winding connected to the high-voltage network is the high-voltage winding, and the winding connected to the low-voltage network is the low-voltage winding.

 

Transformer leads:

1. Transformer leads have three requirements: (electrical performance), (mechanical strength) and (temperature rise requirements).

2.The power transformer leads are (bare copper wire), (paper-wrapped round copper wire), (bare bus bar), (cable) and (copper tube), etc.

3. Our factory adopts lead connection method (brazing) (gas welding) (cold pressure welding) (mechanical connection).

 

Oil Tank:

The basic functions of transformer oil tank can be summarized as protection of oil tank and holding oil, installation skeleton of external components and heat dissipation.

 

What is the role of transformers in power systems?

1. The main function of the transformer in the power system is to change the voltage so as to facilitate the transmission of power.

2. Increasing the voltage can reduce the line loss, improve the economy of power transmission, and achieve the purpose of long-distance power transmission.

3. Reduce the voltage and turn the high voltage into the voltage required by users to meet their needs.

 

 

company profile


 

GNEE New Material has strong production capacity and an efficient marketing team.

 

Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,

 

Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.

 

GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.

 

transformer Workshop equipment display


 

Transformer Test equipment
Test equipment
Transformer Test equipment2
Test equipment

 

Oil transformation workshop
Oil transformation workshop
Dry transformation workshop
Dry transformation workshop

 

Transformer Intelligent automatic bending machine
Intelligent automatic bending machine
Transformer Cnc punch press
Cnc punch press

 

Transformer Intelligent laser cutting machine
Intelligent laser cutting machine
Transformer Welding robot
Welding robot

 

Transformer Fully automatic laminating unit
Fully automatic laminating unit
Transformer Fully automatic laminating unit2
Fully automatic laminating unit

 

Transformer Wire winding unit
Wire winding unit
Transformer Wire winding unit2
Wire winding unit
Transformer Wire winding unit3
Wire winding unit

 

 

 

 

types of transformer from GNEE


 

500kV oil-immersed single-phase double-winding unexcited voltage regulating power transformer

500kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
220kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
66kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
66kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
35kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
35kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
10kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
S(B)H15(21~25)-M sealed amorphous alloy power transformer
SCB three-dimensional core transformer
35kV dry-type non-excitation voltage regulating power transformer
35kV dry-type on-load voltage regulating power transformer
35kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side without excitation voltage regulation
20kV dry-type non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side
SC(B)H15(17~19) amorphous alloy dry type transformer
SG(B)12~18 non-encapsulated H-class dry type transformer
CSD marine transformer
SGB three-dimensional core transformer
New energy transformer
35kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
10kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
Prefabricated cabin substation
Integrated inverter and step-up converter
10000V mine transformer
6000V mine transformer
Buried transformer
Phase-shifting rectifier transformer
Electric furnace transformer
Grounding transformer
QSG/SG three-phase dry isolation transformer
Three-phase pad-mounted transformer
Single-phase pad-mounted transformer
Single-phase pole-mounted transformer

Get Transformer Order specification

GNEE New Material Order specification

When choosing our company's products, please provide the following data to better serve you.

Demander

Demander:

Telephonemethods:

Fax:

Project technical leader:

Telephonemethods:

Mailbox:

Transformer type selection

□Dry transformer

{□SC(B) Epoxy resin □SC(B) Non-encapsulated}

□American Box(ZGS)

{□Terminal type(-Z-) □Ring network type(-H-)}

□European Box change(YBM){□ Dry change □Oil change}

□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow}

□Amorphous alloy transformer{□Dry amorphous □ Oil amorphous}

□ Special transformer{Rectifier, Furnace, Mine, Etc}

Transformer basic data selection

Country of use:

 

Phase number:

□Three-phase(S conventional) □ Monophase □Other( )

Frequency:

□50Hz(conventional) □60Hz □ Other( )

Transformer oil:

□#25(conventional) □#45(minimum temperature below-25℃)

Rated capacity:

□( )kVA Conditions of use □Outdoor type □Indoor type

Altitude:

□Less than 1000m(conventional) □1000-2000m □3000m以上 over

Rated voltage(High voltage)

□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( )

Rated voltage(Low pressure)

□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( )

Connected group

□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( )

Impedance(%):

□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( )

Voltage regulation mode

□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z)

Voltage regulation range

□±2*2.5% □±5% □±3*2.5% □Other( )

Transformer accessory selection

□Fan □Temperature control{□ Common □With 485 computer interface}

□Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel}

□Protection level of dry case(□IP20(Conventional) □IP( )}

□Dry case height requirements{□None □Requirements[ ]}

□ Cable out mode of the dry variable shell

{□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]}

Note:

1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged

2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee)

Other special requirements(additional charges apply below)

Dry transformer

□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo

□Zero sequence transformer □Copper bar to the low voltage cabinet

□Protective mesh □Lighting □100kVA or less Fan □Shock absorber

Oil-immersed transformer

□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator

□400kVA and below low voltage outlet OABC phase with wiring terminals

□630kVA or below requires temperature control

□800kVA or below Low voltage outlet phase 0 requires wiring terminals

□630kVA and below must be equipped with gas relay

 

GNEE New Material Industrial Layout


 

Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan

 

Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa

 

North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica

 

Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom

 

South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile

 

Middle East: The Middle East region

 

Oceania: Australia, Papua New Guinea. Fiji

Send Inquiry