0.23mm CRGO Electrical Steel ≤0.90W/kg for 35kV PV Step-up Transformer

Nov 19, 2026

Leave a message

What is 0.23mm CRGO Electrical Steel ≤0.90W/kg for 35kV PV Step-up Transformer?

 

0.23mm CRGO Electrical Steel with ≤0.90 W/kg core loss is a premium grade of cold rolled grain oriented silicon steel - also known as grain oriented electrical steel (GOES), Si-steel, or transformer core steel - specifically optimized for high-efficiency transformer core applications.

 

The 0.23mm thickness and ≤0.90 W/kg core loss rating (at 1.7T/50Hz) place this material in the upper tier of CRGO grades, offering an excellent balance of performance and cost-effectiveness for 35kV PV step-up transformer applications.

💡 Pro Tip: For 35kV PV step-up transformers, no-load loss is far more important than load loss in terms of total energy loss over a year. Why? Because a typical utility-scale solar plant has a capacity factor of only 20–30%, meaning the transformer is lightly loaded most of the time. Upgrading from a 1.05 W/kg grade to a 0.90 W/kg grade reduces no-load loss by about 14%, and this saving accrues 24 hours a day, every day.

For a 50 MW solar farm with multiple 35kV transformers, this can translate to hundreds of thousands of dollars in additional revenue over the 25-year project lifetime.

 0.23mm CRGO Electrical Steel 0.23mm CRGO Electrical Steel PACKAGING 0.23mm CRGO Electrical Steel factory

Specification - 0.23mm CRGO Electrical Steel ≤0.90W/kg for 35kV PV Step-up Transformer

 

Parameter Specification
Product Name 0.23mm CRGO Electrical Steel ≤0.90W/kg for 35kV PV Step-up Transformer
Grade 23Q090 / 23QG090 (Hi-B or Standard CGO equivalent)
Thickness 0.23 mm (±0.015 mm for prime; ±0.025 mm for secondary)
Core Loss (P1.7/50Hz) ≤0.90 W/kg (guaranteed)
Magnetic Induction (B8) ≥1.85 T (Hi-B grade) / ≥1.80 T (Standard CGO grade)
Silicon Content 3.0 – 3.5%
Coil Width 20 mm – 1,250 mm (full width or custom slit width)
Coil Weight - Master Coil 5 – 12 MT (prime full coil)
Coil Weight - Jumbo Coil 10 – 15 MT (high-volume production)
Coil Weight - Small Coil 0.5 – 3 MT (custom rewound)
Coil ID 508 mm / 610 mm (master); 300–610 mm (custom rewound)
Edge Conditions Mill Edge (ME) / Cut Edge (CE) / Slit Edge (SE) / Trimmed Edge
Surface Coating C-5 / C-6 phosphate insulation coating
Domain Refinement Laser-Scribed (Hi-B) / Non-Laser (Standard CGO)
Lamination Factor ≥96% (prime cut edge) / ≥95% (standard / secondary)
Available Forms Master Coils, Slit Coils, Strips on Reels, Cut-to-Length Sheets
Quality Tiers Premium/Prime / Non-Prime/Secondary
Delivery Condition Fully annealed, stress-relieved, ready for processing
Lead Time 15 – 30 days (stock prime); 7 – 20 days (secondary); 30 – 45 days (custom)
Certification Mill Test Certificate (prime) / Quality Report (secondary)
Standards IEC 60404-8-7, IEC 60076 (transformer standard), ASTM A976

0.23mm CRGO Electrical Steel MTC

Advantages of 0.23mm CRGO Electrical Steel (≤0.90W/kg) for 35kV PV Step-up Transformers

 

1. Low No-Load Loss Maximizes Solar Energy Harvest

With a core loss of just ≤0.90 W/kg at 1.7T/50Hz, this grade of CRGO electrical steel delivers significantly lower no-load loss compared to standard 0.27mm or 0.30mm CGO grades typically used in conventional distribution transformers. For a typical 3,150 kVA 35kV PV step-up transformer, using 0.90 W/kg 0.23mm CRGO instead of 1.20 W/kg 0.27mm CGO reduces no-load loss by approximately 3.5–4.5 kW. 

 

2. High Permeability Enables Compact, Lightweight Transformer Design

The high magnetic induction of 0.23mm CRGO electrical steel (B8 ≥ 1.80–1.85 T) allows PV transformer designers to optimize core dimensions, reducing both material usage and overall transformer size. For 35kV PV transformers - which are often installed in arrays of dozens of units per solar farm - smaller and lighter transformers mean: reduced foundation costs, easier transport to remote solar sites, simpler installation, and less land area required for the transformer platform. 

 

3. Excellent Thermal Cycling Durability for Solar Operating Conditions

Our 0.23mm CRGO electrical steel, with its high-quality C-5/C-6 phosphate insulation coating, maintains excellent inter-lamination insulation integrity through thousands of thermal cycles. 

💡 Pro Tip: For 35kV PV step-up transformers, we recommend designing the core at a slightly lower flux density (1.50–1.60T) than you would for a conventional distribution transformer (1.65–1.75T). Because PV transformers have such low capacity factors, the energy saved from reduced no-load loss far outweighs the slight increase in core material cost. At 1.55T operating flux density, the actual core loss of 0.90 W/kg grade material drops to approximately 0.65–0.70 W/kg - delivering exceptional efficiency during the long hours of light loading.

Manufacturing 35kV PV step-up transformers and need reliable 0.23mm CRGO electrical steel with ≤0.90 W/kg core loss? Get a project-specific quotation with grade selection guidance and flexible delivery options - tailored to solar transformer production.

Request PV Steel Quote →

Electrical Steel Electromagnetic Performance and Application - 35kV PV Step-up Transformer Cores

 

Because PV transformers spend so much time at low load, the core loss profile of the electrical steel is the single most important material parameter affecting transformer energy efficiency.

 

Let's examine how 0.23mm CRGO electrical steel with ≤0.90 W/kg core loss performs under realistic PV operating conditions:

  • At rated flux density (1.7T): The material delivers the guaranteed 0.90 W/kg core loss. This represents the worst-case loss scenario at maximum flux.
  • At typical PV operating flux density (1.55T): Because most PV transformers are designed at lower flux densities to optimize no-load loss, the actual operating core loss is significantly lower than the rated value. At 1.55T, the core loss of 0.90 W/kg grade material drops to approximately 0.68–0.72 W/kg - about 20–25% lower than the rated value at 1.7T.
  • Annual energy loss comparison: For a 2,500 kVA 35kV PV transformer with a 25% annual capacity factor:
  • Using 0.23mm CRGO ≤0.90 W/kg: ~2,200 kWh/year core loss energy
  • Using 0.27mm CGO ≤1.20 W/kg: ~3,000 kWh/year core loss energy

 

0.23mm CRGO Electrical Steel   PV Step-Up Transformer core  PV Step-Up Transformer

 

Case Study: 3,150 kVA 35kV PV Step-up Transformer with 0.23mm CRGO (≤0.90 W/kg)

Consider a typical 3,150 kVA 35kV / 0.69kV oil-immersed PV step-up transformer with a core built from 0.23mm CRGO electrical steel with ≤0.90 W/kg core loss, designed at 1.6T operating flux density for optimized PV performance:

  • Core weight: Approximately 3,000 kg
  • No-load loss (guaranteed): ≤2.6 kW
  • Load loss at rated: ≤24 kW
  • Total loss at rated: ≤26.6 kW
  • Efficiency at 100% load: 99.16%
  • Efficiency at 50% load: 99.34%
  • Efficiency at 25% load: 99.28%
  • Exciting current: ≤0.4% of rated current
  • Noise level: ≤60 dB(A) at 1m distance
  • Winding temperature rise: ≤65K (oil-immersed, ONAN cooling)

 

This performance level easily meets the requirements of most utility-scale solar projects and typically exceeds the efficiency of PV transformers built with standard 0.27mm or 0.30mm CGO material. The 0.23mm ≤0.90 W/kg grade strikes an excellent balance between performance and cost - significantly better than standard grades without the price premium of top-tier 0.80 W/kg laser-scribed material.

0.23mm CRGO Electrical Steel (≤0.90W/kg) Price

 

Market analysis for 2026 indicates that Hi-B and mid-premium CRGO prices are expected to remain firm or increase slightly (0–8%), driven by continued strong demand from the renewable energy and utility transformer sectors. Global average electrical steel prices are forecast in the range of USD 1.75–1.95/kg for the second half of 2026. Mid-premium grades like 0.90 W/kg 0.23mm CRGO are in particularly strong demand as more PV projects specify higher-efficiency transformers.

 

Price Range by Delivery Condition - 0.23mm CRGO ≤0.90 W/kg

Delivery Form Price Range (USD/MT) Best For
Prime Master Coil (Mill Edge) $1,700 – $1,950 Manufacturers with in-house slitting
Prime Master Coil (Cut Edge) $1,750 – $2,000 Direct lamination stamping, stacked cores
Slit Coil (precision slit) $1,850 – $2,100 Wound cores, toroidal cores, strip feed
Small Rewound Coil $1,950 – $2,200 Small-batch production, prototyping
Jumbo Coil (10–15 MT) $1,650 – $1,900 High-volume OEMs, automated lines
Cut-to-Length Sheets $1,900 – $2,150 Lamination production, stacked core assembly
Secondary / Non-Prime Coil $1,250 – $1,600 Cost-sensitive distributed PV projects

Note: Indicative FOB China prices as of 2026 Q4 estimate. Prices vary by order quantity, specific grade, coil width, packaging requirements, payment terms, and current market conditions. Prices for 0.23mm ≤0.90 W/kg grade sit between standard CGO and top-tier laser-scribed Hi-B in the CRGO price hierarchy.

Bidding on a solar project and need competitive 0.23mm CRGO electrical steel pricing for 35kV step-up transformers? Get a project-specific quotation with volume discounts and flexible pricing terms - we support PV transformer manufacturers from prototype to mass production.

Get Project Pricing →

Value-Added Services for 35kV PV Transformer CRGO Supply

 

We understand the unique supply chain challenges of the solar PV industry - tight project timelines, variable production volumes, stringent quality requirements, and complex logistics to remote project sites. Our comprehensive value-added services are designed to support PV transformer manufacturers at every stage of project execution:

 

Complete Product Range for All PV Transformer Types

  • Premium / Prime Coils: Full-certified mill-direct material with complete traceability - for utility-scale PV projects requiring full documentation and guaranteed performance. Available in Mill Edge (ME) and Cut Edge (CE) delivery conditions. Includes full Mill Test Certificate per coil.
  • Non-Prime / Secondary / Concession Coils: Cost-effective options with various concession levels - from minor cosmetic defects to off-grade properties. All with full defect disclosure. Ideal for distributed PV, commercial rooftop solar, and price-sensitive domestic market projects.
  • Jumbo / Over-Sized Coils: Extra-large coils (10–15 MT) for high-volume PV transformer OEMs with automated production lines. Minimizes changeovers and maximizes line efficiency. Available in both prime and secondary quality tiers.
  • Small Rewound Coils: Custom-rewound small coils (0.5–3 MT) for prototype development, small-batch production, and PV projects with multiple transformer sizes. Perfect for manufacturers serving the distributed solar market.

 

CRGO Electrical Steel  Electrical Steel  CRGO Electrical Steel  Electrical Steel

 

Processing & Customization Services

  • Precision Slitting Service: Slitting to exact core leg widths with multiple tolerance levels. Premium quality with ≤0.015mm burr height available for high-efficiency designs. Slit Edge (SE) delivery condition. Multi-width optimization to maximize material yield.
  • Cut-to-Length Sheets: Shearing to exact lamination lengths with optional 45° miter cutting for step-lap core designs. Cut Edge (CE) delivery with clean sheared ends. Length tolerance options from ±0.5mm (standard) to ±0.2mm (precision).
  • Laser-Scribed & Non-Laser Options: Both laser-scribed Hi-B and standard non-laser CGO grades available in the 0.90 W/kg performance range. Match the exact grade to your efficiency target and budget.
  • Strips on Reels: Slit strips on heavy-duty reels for continuous wound-core production lines used in dry-type and compact PV transformers. Optional interleaved paper for surface protection.

 

CRGO Electrical Steel  Processing & Customization Services

Electrical Steel Processing & Customization Services

Edge Conditions Available

Edge Type Description PV Transformer Application
Mill Edge (ME) Original as-rolled edge from the steel mill Feedstock for in-house slitting lines
Cut Edge (CE) Side-trimmed to exact width, clean square edge, deburred Direct lamination stamping for stacked core PV transformers
Slit Edge (SE) Precision longitudinally sheared, controlled burr height Wound core and toroidal core PV transformers
Trimmed Edge Lightly trimmed edges, medium precision Economy-class PV transformers, cost-sensitive projects

silicon steel packaging and shipping

💡 Pro Tip: For PV projects in remote locations with long overland transport (e.g., desert solar farms in MENA, high-altitude projects in Latin America), we strongly recommend our "project-grade" packaging upgrade. The additional $50–80/MT cost for reinforced packaging is negligible compared to the risk of coil damage during the final leg of transport to the site, where handling equipment may be less sophisticated than at major ports.

Scaling up PV transformer production for a major solar project?
Partner with us for reliable 0.23mm CRGO electrical steel supply with ≤0.90 W/kg core loss - available in all delivery conditions from prime certified to cost-effective secondary coils. We grow with your solar business.

FAQ

 

Why is 0.23mm CRGO with ≤0.90 W/kg the preferred grade for 35kV PV step-up transformers?

0.23mm CRGO with ≤0.90 W/kg core loss strikes the optimal balance between performance and cost for 35kV PV step-up transformers. Here's why: (1) The 0.23mm thickness provides low eddy current loss - ideal for the long no-load periods of PV transformers.

(2) The ≤0.90 W/kg core loss rating is high enough to meet most utility-scale solar project efficiency requirements without the significant price premium of top-tier 0.80 W/kg laser-scribed grades.

(3) This grade is widely available from multiple mills, ensuring supply security and competitive pricing.

(4) For PV transformers designed at 1.55–1.6T flux density (typical for solar), the actual operating loss is even lower than 0.90 W/kg - typically 0.65–0.75 W/kg - delivering excellent real-world efficiency. Most PV transformer manufacturers find that this grade offers the best value proposition for mainstream utility-scale solar projects.

 

How does the 0.90 W/kg rating translate to actual core loss in a PV transformer?

The 0.90 W/kg rating is measured at 1.7 Tesla and 50Hz (P1.7/50) under standardized Epstein test conditions. In an actual transformer core, the actual core loss per kg will be different due to several factors:

(1) Operating flux density: Most PV transformers operate at 1.5–1.6T, not 1.7T, so the actual loss per kg is lower - roughly 0.65–0.75 W/kg at 1.55T.

(2) Core build factor: Cutting, stacking, and joint losses increase the actual core loss above the material rating - typically by 10–20% for well-built cores.

(3) Joint design: Step-lap miter joints have lower build loss than butt joints. So a 0.90 W/kg material might result in actual core loss of about 0.80–0.90 W/kg in a well-designed core operating at 1.55T. The exact number depends on your specific core design and manufacturing quality.

 

Send Inquiry