S11 Series Three Phase Oil Immersed Distribution Transformer

Nov 11, 2025

Leave a message

S11 Series Three Phase Oil Immersed Distribution Transformer

The S11 series is a type of three-phase oil-immersed distribution transformer known for being energy-efficient, reliable, and requiring low maintenance. It uses a fully sealed, corrugated oil tank that isolates the transformer oil from the air to slow down oil and insulator aging, while the core is made from high-quality cold-rolled silicon steel for high efficiency. Key features include low loss, low noise, a strong ability to withstand short circuits, and a design that extends its service life without needing a conservator tank.

 

S11 Series Three Phase Oil Immersed Distribution Transformer feature

lron core:

the iron core is made by crystal grain-oriented silicon-steel sheet; GEORG cross cut shear (made in West Germany) is adopted to cut the silicon-steel sheet with a 45*joint seam; fold the sheet into a multistage roll cross-section to reduce the noise and power consumption.

 

Coil:

cylinder type for high voltage; cylinder type or foil type for low voltage; this can increase the ability to resist short circuit and strike; and the distribution of magnetic path is more rational.

 

Oil tank:
the oil tank is made by fine cold-rolled steel sheets; GEORG corrugation oil tank production-line is adopted; to meet environmental needs, then, antiseptic coating material is applied on the surface, which can meet the requirements for petroleum and chemical industry (much oil stain and many chemical substances). In addition, the corrugations not any possess heat radiation function, but also meet the requirement for oil expansion and oil contraction trader normal performance. The isolation from air guarantees a low aging speed of oil and a long life expectancy of transformer.

 

Insulation structure:

oil-immersed distribution transformer adopts A-level insulation structure; high voltage coil and low voltage coil are concentric; the space between coils is cardboard sleeve small oil clearance oil partition structure.

 

Model

S11 Series Three Phase Oil Immersed Distribution Transformer

 

Three Phase Oil Immersed Transformer Technical Parameters

Rated Capacity Voltage Combination Vector Group No-load Loss Load Loss No-load Current Impedance Voltage Total Weight Exterior Size Installation center
/Installation hole
(kVA) High voltage
(kV)
Tap range Low voltage
(kV)
  (W) (W) (%) (%) (kg) (L*W*H) (mm) (mm)
30 6
6.3
10
10.5
11
±5%
or
±2*2.5%
0.4 Ydn0
or
Dyn11
100 630/600 1.8 4.0 335 1030*690*860 400*400/4*Φ14
50 130 910/870 1.6 410 1045*700*925 400*400/4*Φ14
63 150 1090/1040 1.5 460 1075*710*940 400*400/4*Φ14
80 180 1310/1250 1.4 490 1080*715*995 400*400/4*Φ19
100 200 1580/1500 1.3 550 1110*730*1020 400*400(550)/4*Φ19
125 240 1890/1800 1.2 615 1135*740*1035 400*400(550)/4*Φ19
160 280 2310/2200 1.1 695 1155*755*1050 550*550/4*Φ19
200 340 2730/2600 1 790 1200*770*1075 550*550/4*Φ19
250 400 3200/3050 0.9 930 1240*800*1100 550*550/4*Φ19
315 480 3830/3650 0.8 1110 1305*840*1120 550*550/4*Φ19
400 570 4520/4300 0.7 1290 1390*900*1160 660*660/4*Φ19
500 680 5410/5150 0.7 1510 1500*990*1195 660*660/4*Φ19
630 810 6200 0.6 4.5 1730 1580*1030*1305 660*660/4*Φ19
800 980 7500 0.6 2075 1705*1140*1360 820*820/4*Φ19
1000 1150 10300 0.5 2490 1730*1290*1395 820*820/4*Φ19
1250 1360 12000 0.4 2960 1780*1320*1480 820*820/4*Φ19
1600 1640 14500 0.4 3515 1890*1430*1520 820*820/4*Φ19
2000 1940 18300 0.4 5 4880 2050*1360*1840 820*820/4*Φ19
2500 2290 21200 0.4 6010 2170*1430*2015 1070*1070/4*Φ19

 

200 KVA power transformer to China

Model

S11-200 KVA-11/0.4KV

Type

Oil Immersed Distribution Transformer

Standard

IEC60076

Rated Power

200 KVA

Frequency

50 HZ

Phase

Three

Cooling Type

ONAN

Primary Voltage

11 KV

Secondary Voltage

400 V

Winding Material

Copper

Vector Group

Dyn11

Impedance

4%

Tap Changer

NLTC

Tapping Range

±2*2.5%

No Load Loss

0.34KW

On Load Loss

2.6KW

Accessories

Standard Configuration

 

Three Phase Oil filled Transformer applications

  • Power distribution: For stepping down high voltages to lower voltages for distribution in industrial and agricultural power grids.
  • Industrial and mining applications: In industrial facilities and mines for their specific power requirements.
  • Urban and rural power grid upgrades: As a key component in upgrading and expanding power grids.
  • Substations: Used in combined and prefabricated substations.
  • General power distribution: Applicable to a wide range of applications, including lighting and other general power needs in commercial and residential areas.

 

Purpose of measuring winding resistance:

1. Whether the wire is welded or connected in good condition.

2. Whether the wire specification and resistivity meet the requirements.

3. Whether the resistances of each phase are balanced.

4. Provide basis for temperature rise test.

 

 

company profile


 

GNEE TRANSFORMER has strong production capacity and an efficient marketing team.

 

Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,

 

Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.

 

GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.

 

transformer Workshop equipment display


 

Transformer Test equipment
Test equipment
Transformer Test equipment2
Test equipment

 

Oil transformation workshop
Oil transformation workshop
Dry transformation workshop
Dry transformation workshop

 

Transformer Intelligent automatic bending machine
Intelligent automatic bending machine
Transformer Cnc punch press
Cnc punch press

 

Transformer Intelligent laser cutting machine
Intelligent laser cutting machine
Transformer Welding robot
Welding robot

 

Transformer Fully automatic laminating unit
Fully automatic laminating unit
Transformer Fully automatic laminating unit2
Fully automatic laminating unit

 

Transformer Wire winding unit
Wire winding unit
Transformer Wire winding unit2
Wire winding unit
Transformer Wire winding unit3
Wire winding unit

 

 

 

 

types of transformer from GNEE


 

500kV oil-immersed single-phase double-winding unexcited voltage regulating power transformer

500kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
220kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
66kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
66kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
35kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
35kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
10kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
S(B)H15(21~25)-M sealed amorphous alloy power transformer
SCB three-dimensional core transformer
35kV dry-type non-excitation voltage regulating power transformer
35kV dry-type on-load voltage regulating power transformer
35kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side without excitation voltage regulation
20kV dry-type non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side
SC(B)H15(17~19) amorphous alloy dry type transformer
SG(B)12~18 non-encapsulated H-class dry type transformer
CSD marine transformer
SGB three-dimensional core transformer
New energy transformer
35kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
10kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
Prefabricated cabin substation
Integrated inverter and step-up converter
10000V mine transformer
6000V mine transformer
Buried transformer
Phase-shifting rectifier transformer
Electric furnace transformer
Grounding transformer
QSG/SG three-phase dry isolation transformer
Three-phase pad-mounted transformer
Single-phase pad-mounted transformer
Single-phase pole-mounted transformer

Get Transformer Order specification

GNEE Transformer Order specification

When choosing our company's products, please provide the following data to better serve you.

Demander

Demander:

Telephonemethods:

Fax:

Project technical leader:

Telephonemethods:

Mailbox:

Transformer type selection

□Dry transformer

{□SC(B) Epoxy resin □SC(B) Non-encapsulated}

□American Box(ZGS)

{□Terminal type(-Z-) □Ring network type(-H-)}

□European Box change(YBM){□ Dry change □Oil change}

□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow}

□Amorphous alloy transformer{□Dry amorphous □ Oil amorphous}

□ Special transformer{Rectifier, Furnace, Mine, Etc}

Transformer basic data selection

Country of use:

 

Phase number:

□Three-phase(S conventional) □ Monophase □Other( )

Frequency:

□50Hz(conventional) □60Hz □ Other( )

Transformer oil:

□#25(conventional) □#45(minimum temperature below-25℃)

Rated capacity:

□( )kVA Conditions of use □Outdoor type □Indoor type

Altitude:

□Less than 1000m(conventional) □1000-2000m □3000m以上 over

Rated voltage(High voltage)

□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( )

Rated voltage(Low pressure)

□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( )

Connected group

□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( )

Impedance(%):

□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( )

Voltage regulation mode

□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z)

Voltage regulation range

□±2*2.5% □±5% □±3*2.5% □Other( )

Transformer accessory selection

□Fan □Temperature control{□ Common □With 485 computer interface}

□Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel}

□Protection level of dry case(□IP20(Conventional) □IP( )}

□Dry case height requirements{□None □Requirements[ ]}

□ Cable out mode of the dry variable shell

{□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]}

Note:

1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged

2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee)

Other special requirements(additional charges apply below)

Dry transformer

□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo

□Zero sequence transformer □Copper bar to the low voltage cabinet

□Protective mesh □Lighting □100kVA or less Fan □Shock absorber

Oil-immersed transformer

□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator

□400kVA and below low voltage outlet OABC phase with wiring terminals

□630kVA or below requires temperature control

□800kVA or below Low voltage outlet phase 0 requires wiring terminals

□630kVA and below must be equipped with gas relay

 

GNEE TRANSFORMER Industrial Layout


 

Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan

 

Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa

 

North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica

 

Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom

 

South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile

 

Middle East: The Middle East region

 

Oceania: Australia, Papua New Guinea. Fiji

Send Inquiry