S9 Series Three-phase Oil-immersed Distribution Transformer
Nov 11, 2025
Leave a message
S9 Three-phase Oil-immersed Distribution Transformer Product Overview
The three-phase oil-immersed transformer is an essential equipment widely used in power systems, primarily for voltage transformation, power transmission, and distribution. Employing an oil-immersed cooling method, it exhibits high efficiency, stability, and durability, making it a crucial component in the power industry.


Three-phase Oil-immersed Transformer Product Features
High Efficiency and Energy Saving: Optimized electromagnetic design and the use of high-conductivity materials reduce no-load and load losses, enhancing energy utilization efficiency.
Stable Operation: Advanced insulating materials and processes ensure stable transformer operation in harsh environments, minimizing failure rates.
Superior Heat Dissipation: The oil-immersed cooling method rapidly dissipates heat generated during transformer operation, ensuring long-term stable performance.
Convenient Maintenance: Compact structure, easy installation, and low maintenance costs facilitate routine maintenance and inspections.
Three-phase Oil type Transformer Application
The three-phase oil-immersed transformer is widely used in power plants, substations, industrial and mining enterprises, providing stable and reliable voltage transformation and power transmission services for power systems.
Service Guarantee
We provide comprehensive pre-sales, in-sales, and after-sales services, offering professional technical support and solutions to ensure timely and effective assistance for users during the usage process.
Service Condition
Transformer normal use conditions
The altitude does not exceed 1000m;
Ambient temperature:
Maximum temperature +40℃
The average temperature of the hottest month is +30°C
The highest annual average temperature +20℃
Outdoor minimum temperature -25℃
Transformer special use conditions
The altitude exceeds 1000m;
Ambient temperature:
Maximum temperature +40℃
Minimum temperature -25℃
(Specify when ordering)
Tech data of 33KV S9 series distribution transformer

How to Select the Right Oil-filled Transformer
Choosing the right transformer involves more than voltage and power. Consider the following:
1. Power Rating (kVA/MVA)
Select a rating 10–20% higher than your maximum estimated load to avoid overheating.
2. Primary/Secondary Voltage
Match your grid or generator specs (e.g., 11kV/400V, 33kV/690V).
3. Cooling Type
ONAN (Oil Natural, Air Natural)
ONAF (Oil Natural, Air Forced)
4. Insulation Level & Temperature Rise
Ensure it meets IEC/ANSI standards for your region and climate conditions.
5. Tap Changer
Choose between:
Off-Load Tap Changer (manual)
On-Load Tap Changer (OLTC) for voltage fluctuation adjustment
6. Environmental Requirements
For dusty, humid, or high-altitude areas, ensure protective enclosures and oil-type compatibility.
company profile
GNEE New Material has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE New Material Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE New Material Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji