S11 oil power transformer
Nov 07, 2025
Leave a message
S11 oil power transformer description
The S11 oil power transformer coil is wound with high-quality oxygen-free copper wire. The heat dissipation adopts a new oil channel structure. The design is reasonable, and the insulation process is optimized to improve the mechanical strength and short-circuit resistance. The core is made of high-quality cold-rolled silicon steel sheet with stepped three-level seams. The surface is coated with cured paint which reduces the loss and noise with beautiful appearance and reliable operation.

S11 oil immersed transformer Technical Parameter
| (can customize it according to your techncial data) | ||||||||||
| Rated Capacity(KVA) |
Voltage Combination | Vector Group |
No-load Loss (KW) |
Load Loss (KW) |
No-load Curent% |
Short-circuitimpedance | Weight (kG) | |||
| High Voltage(KA) | High Voltage Tapping Range |
Low Voltage(KA) | Oil Weight | Gross Weight | ||||||
| 50 | 20-10 |
±5×2.5% ±2×2.5% |
0.4 |
Dyn11 |
0.13 | 0.96 | 2 | 5.5 |
150 | 495 |
| 63 | 0.15 | 1.145 | 1.9 | 170 | 560 | |||||
| 80 | 0.18 | 1.37 | 1.8 | 190 | 635 | |||||
| 100 | 0.20 | 1.65 | 1.6 | 215 | 710 | |||||
| 125 | 0.24 | 1.98 | 1.5 | 250 | 840 | |||||
| 160 | 0.29 | 2.42 | 1.4 | 285 | 945 | |||||
| 200 | 0.33 | 2.86 | 1.3 | 340 | 1125 | |||||
| 250 | 0.40 | 3.35 | 1.2 | 390 | 1295 | |||||
| 315 | 0.48 | 4.01 | 1.1 | 445 | 1475 | |||||
| 400 | 0.57 | 4.73 | 1.0 | 515 | 1712 | |||||
| 500 | 0.68 | 5.66 | 1.0 | 6.0 |
460 | 1995 | ||||
| 630 | 0.81 | 6.82 | 0.9 | 565 | 2450 | |||||
| 800 | 0.98 | 8.25 | 0.8 | 635 | 2765 | |||||
| 1000 | 1.15 | 11.33 | 0.7 | 840 | 3650 | |||||
| 1250 | 1.35 | 13.20 | 0.7 | 970 | 4220 | |||||
| 1600 | 1.63 | 15.95 | 0.6 | 1105 | 4800 | |||||
| 2000 | 1.95 | 19.14 | 0.6 | 1205 | 5240 | |||||
| 2500 | 2.34 | 22.22 | 0.5 | 1300 | 5650 | |||||
The advantages of S11 oil filled transformer
The fully sealed power transformer eliminates the oil storage tank and uses the fins of the corrugated oil tank body as heat dissipation and cooling elements. At the same time, it expands and contracts with the increase and decrease of the transformer oil which isolates the inside of the transformer from the atmosphere and prevents the deterioration of the oil and the insulation from moisture and aging to enhance the reliability of operation.
The core uses high-quality cold-rolled silicon steel sheet which effectively improves the distribution of magnetic flux density inside the core, reduces noise and reduces losses. The coil is made of high-strength enameled wire with a cylindrical structure. The ampere-turn distribution is even, the insulation structure is reasonable, and it has strong short-circuit resistance.
The fasteners used in the fuel tank are all non-return nuts which can ensure that they will not be loosened during long-distance transportation. The surface of the fuel tank is coated with three anti-paints after phosphating treatment. It is widely used in places where the use of metallurgy, ore, petrochemical and other harsh environments.
The features of S11 oil filled transformer
The cores of series power transformers are made of silicon steel sheet and rolled without seams and non-gradations, which are close to pure circular cross sections. The iron yoke and the iron core are connected with rounded corners, and the iron core is closed.
High and low voltage coils are directly wound on the iron core. The two coils have good concentricity and good short circuit resistance.
Due to the special iron core structure, it is also annealed by rolling crystalline oriented high-quality cold-rolled silicon steel sheets which makes the S11 oil power transformer reduce the no-load loss by 30% and the no-load current by 70% compared with the S9 type The noise dropped about 8 decibels.
Cancel the oil storage tank of the power transformer. A corrugated plate oil tank is used. The oil volume change caused by temperature is adjusted by the elasticity of the corrugated sheet to isolate the transformer oil from the air and prolong its use.
The power transformer adopts a corrugated oil tank with a small temperature rise area and beautiful appearance.
The core processing is all mechanized which reduces labor intensity and improves product quality and quality.
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji