Oval Magnetic Nanocrystalline Cores for Instrument Current Transformers
Sep 22, 2025
Leave a message
Oval magnetic nanocrystalline cores are closed magnetic circuits produced by winding iron-based nanocrystalline ribbon into an oval (race-track) shape and annealing it in a magnetic field. The oval geometry provides a long, straight window that fits the primary conductor or bushing of an instrument current transformer, while the nanocrystalline material delivers the high permeability and low coercivity that modern metering and protection accuracy classes require. This article describes the key properties, typical applications and parameter values of these cores.
Why Nanocrystalline Material for Instrument Transformers?
The accuracy of an instrument current transformer depends on how closely the secondary current reproduces the primary current, which in turn depends on the magnetizing current drawn by the core. A core with higher permeability and lower coercivity draws less magnetizing current and produces smaller ratio and phase errors. Nanocrystalline ribbon offers:
Higher permeability than silicon steel cores, giving higher measuring accuracy at the same core size.
Performance close to Mu-metal (high-permeability nickel-iron alloy) at a lower material cost.
Higher saturation induction than ferrite, so the core can carry the fault current without saturating prematurely.
Lower manufacturing cost than permalloy for the same accuracy performance.
Wide operating temperature range from -30 °C to +180 °C, covering outdoor and switchgear service.
Key Material Parameters
| Typical Parameter | Value |
|---|---|
| Saturation induction density | Bs = 1.2 T |
| Material permeability | μo > 8×10&sup4; Gs/Oe |
| Crystallization temperature | Tx > 510 °C |
| Vickers hardness | Hv = 880 kg/mm² |
| Curie temperature | Tc > 570 °C |
| Density | ρ = 7.2 g/cm³ |
| Electrical resistivity | ≥ 130 μΩ·cm |
| Ribbon thickness | 29–35 µm |
| Lamination factor | 0.75–0.82 |
The high Curie temperature and crystallization temperature mean the core keeps its magnetic properties across the full service temperature range of switchgear and transformers, and the high resistivity keeps eddy-current loss low at power frequency and above. The lamination factor reflects the space occupied by the ribbon layers and coating in the wound core stack.
Accuracy Performance in Instrument Current Transformers
Instrument current transformer cores made from this material are used to achieve accuracy classes 0.2 and 0.2s for metering, which limit the ratio error to 0.2% and the phase error to 10 minutes at rated current (with tighter requirements at 1% and 5% current for class 0.2s). Because the magnetizing current is very small, the excitation current contributes little error, and the low remanence of the annealed core supports stable operation of protection windings as well. The oval shape is particularly suitable for bushing-type current transformers, where the primary is a single conductor passing through the core window.
Typical Applications
Instrument current transformer cores with accuracy class 0.2 and 0.2s.
Bushing current transformers for epoxy resin cast, gas-insulated (GIS) and oil-immersed switchgear.
Current sensing in LV, MV and HV switchgear panels.
Power system relay protection current transformers.
Power monitoring and metering devices.
In all of these applications the core is wound into the required shape, annealed, and usually encased or impregnated before the secondary winding is applied.
Comparison with Alternative Materials
Compared with silicon steel, the nanocrystalline core gives higher permeability and therefore smaller ratio and phase errors for the same cross-section, which lets the designer reduce the core size while keeping accuracy. Compared with Mu-metal and permalloy, the nanocrystalline core offers a very similar high-permeability performance at lower material cost, and its saturation induction of 1.2 T is higher than that of most nickel-iron alloys, which improves behavior under fault current. These factors make oval nanocrystalline cores a cost-effective choice for precision current transformers in modern substations.
FAQ
What is an oval nanocrystalline core used for?
It is used as the magnetic circuit of instrument current transformers, especially bushing-type designs, where a primary conductor passes through the oval window and the secondary winding is wound around the core. Its high permeability gives the accuracy needed for metering and protection.
What accuracy class can be achieved with nanocrystalline cores?
With appropriate winding and burden design, accuracy classes 0.2 and 0.2s are achievable, meaning the ratio error stays within 0.2% and the phase error within 10 minutes at rated current. Class 0.2s also maintains accuracy down to 1% of rated current.
How does the oval shape benefit a current transformer?
The oval window gives a long straight passage for the primary conductor or bushing, which simplifies assembly in cast-resin and GIS switchgear, while the closed magnetic path keeps the stray field low and the magnetizing current small.
What is the working temperature range of these cores?
The operating temperature range is -30 °C to +180 °C. The Curie temperature above 570 °C and crystallization temperature above 510 °C guarantee stable magnetic performance well beyond normal service conditions.
Why is the lamination factor below 1?
The lamination factor is the ratio of the effective magnetic cross-section to the geometric cross-section of the wound core. It is less than 1 because of the ribbon surface roughness, the insulating coating between layers and the space between adjacent turns.