Nanocrystalline toroidal cores are used in current transformers because the material combines low losses and high permeability with a saturation flux density higher than that of nickel-iron (NiFe) alloys and cobalt-based amorphous alloys. Compared with NiFe cores, nanocrystalline cores offer better permeability throughout the B-H curve and a higher saturation induction. Compared with silicon steel, the saturation is lower, but the thin ribbon and material chemistry give a much better power loss. These properties make nanocrystalline cores an excellent choice for metering and protection current transformers.

Why Nanocrystalline Cores for Current Transformers

A current transformer measures the current flowing in a conductor by reproducing a proportional current in its secondary winding. The accuracy of this reproduction depends on the core material. Nanocrystalline material provides high permeability, which minimizes the magnetizing current and therefore the ratio and phase errors of the transformer. High saturation induction allows the core to carry the rated current plus fault current without saturating prematurely. In addition, the core is smaller and lighter than an equivalent nickel-iron alloy core, which simplifies the design of compact switchgear.

Core Finishing Options

Plastic cases in PBT, PA66, or DMC materials for protection and easy mounting.

Metal cases in stainless steel or aluminum for higher mechanical strength.

Insulation tape or epoxy coating for electrical insulation and edge protection.

Split cores, which open for easy assembly around existing conductors in retrofit installations.

Rectangular and stadium-shaped cores can be customized to suit the application.

Key Features

High permeability over the full B-H curve.

Minimized current measuring error in current transformers.

High saturation induction.

Small size and light weight compared with nickel-iron alloy CT cores.

Excellent thermal stability, with long-term operation from minus 55 to plus 120 degrees Celsius.

Low cost and good linearity.

Protection with plastic cases or stainless steel cases.

Wide range of permeabilities to match different accuracy requirements.

Typical Applications

Current transformers with accuracy classes 0.1, 0.2, and 0.2s.

Bushing current transformers for gas-insulated and oil-immersed switchgear.

Current transformers in low-voltage, medium-voltage, and high-voltage switchgear.

Measuring and protection transformers in power transmission and distribution systems.

Residual current devices and earth leakage protection.

Dimension Examples

The table below lists representative nanocrystalline toroidal core dimensions. Core dimensions are given as inner diameter x outer diameter x height in millimeters, and the finished core size includes the case.

Core Dimensions da x di x h (mm) Finished Core Size OD x ID x H (mm) Core Weight (g) Case Material
19 x 14 x 6.5 22.2 x 12 x 9 4.8 PBT
21 x 16 x 10 23.8 x 14.5 x 12.5 8.3 PBT
26 x 19 x 10 29 x 16.5 x 12.5 14.0 PBT
40 x 30 x 10 43 x 27.5 x 12.5 32.0 DMC
83 x 38 x 40 88 x 34 x 45 967.0 DMC
265 x 210 x 10 271 x 203 x 17 1249.0 Stainless Steel
220 x 180 x 30 227 x 172 x 35 2295.0 Stainless Steel

Cores with other specifications can be provided according to customer requirements.

Design Considerations

Select the core size according to the rated primary current, the burden of the connected instrument, and the required accuracy class.

Choose a split core when the transformer must be installed around an existing conductor without disconnecting it.

Consider the continuous operating temperature and the required creepage distance when selecting the case material.

Verify the linearity of the permeability over the expected current range to keep the measurement error within class limits.

Frequently Asked Questions

Q1. Why are nanocrystalline cores used in current transformers?

Nanocrystalline material offers high permeability and low loss, which minimize the magnetizing current and reduce the ratio and phase errors of the current transformer, while providing higher saturation than nickel-iron alloys.

Q2. What accuracy classes can be achieved?

Nanocrystalline CT cores are commonly used for accuracy classes 0.1, 0.2, and 0.2s, which cover metering applications with strict error limits.

Q3. What is the operating temperature range?

Nanocrystalline cores can operate continuously from about minus 55 to plus 120 degrees Celsius, which covers indoor and outdoor switchgear applications.

Q4. What is a split core?

A split core is cut or hinged so that it can be opened and clamped around a conductor without disconnecting the circuit, which is convenient for retrofits and temporary measurements.

Q5. How is the core finished?

Common finishes include plastic cases in PBT, PA66, or DMC, metal cases in stainless steel or aluminum, insulation tape, and epoxy coating. The finish protects the ribbon edges and provides the required insulation.

Q6. Can cores be supplied in custom dimensions?

Yes. Rectangular, stadium-shaped, and other geometries can be customized, and cores can be built to the specific dimensions and accuracy requirements of the project.