Internal Structure of a 630kVA Oil Filled Transformer: Core, Windings and Insulation System Explained
Mar 17, 2026
Leave a message
Understanding the internal design is essential for engineers and buyers who want to ensure transformer reliability, efficiency, and long service life. The Internal Structure of a 630kVA Oil Immersed Transformer directly determines its electrical performance, thermal stability, and resistance to faults.

GNEE New Material is a professional transformer manufacturer and global exporter, specializing in high-quality 630kVA oil immersed transformers for industrial plants, renewable energy projects, utilities, and infrastructure construction. With advanced production lines, strict testing standards, and extensive export experience, GNEE ensures each transformer is engineered for durability, efficiency, and safety.
In this guide, we will break down the core, windings, and insulation system-the three key internal components that define transformer performance.
Core Structure in a 630kVA Oil Immersed Transformer
The magnetic core is one of the most critical parts of the internal structure of a 630kVA oil immersed transformer, as it directly affects efficiency and no-load losses.
Core Material and Design
Modern transformers typically use:
- Cold Rolled Grain Oriented (CRGO) silicon steel
- High magnetic permeability materials
- Low hysteresis loss design
The core is constructed using thin laminated sheets to reduce eddy current losses. These laminations are insulated from each other to minimize circulating currents.
Step-Lap Core Technology
Advanced step-lap core design is widely used in high-efficiency transformers:
- Reduces magnetic flux leakage
- Minimizes noise and vibration
- Improves energy efficiency
This design is especially important for S13 high-efficiency transformers, where low no-load loss is critical.

Transformer core assembly with laminated CRGO silicon steel sheets.
Windings Design in a 630kVA Oil Immersed Transformer
The windings are responsible for energy transfer within the internal structure of a 630kVA oil immersed transformer.
✅️Types of Windings
There are two main windings:
- High Voltage (HV) winding
- Low Voltage (LV) winding
These windings are typically arranged concentrically:
- LV winding placed closer to the core
- HV winding placed outside for insulation safety
✅️Conductor Material
Windings can be made of:
- Copper (preferred for high efficiency and conductivity)
- Aluminum (cost-effective alternative)
Copper windings offer:
- Lower electrical resistance
- Reduced load losses
- Better thermal performance
✅️Winding Configuration
Common configurations include:
- Cylindrical winding
- Helical winding
- Disc winding (for higher voltage applications)
Proper winding design ensures:
- Uniform current distribution
- Mechanical strength during short circuits
- Efficient heat dissipation
Insulation System in a 630kVA Oil Immersed Transformer
The insulation system is essential to the internal structure of a 630kVA oil immersed transformer, ensuring electrical isolation and thermal protection.
✅️Solid Insulation Materials
Typical solid insulation includes:
- Insulating paper (cellulose-based)
- Pressboard
- Insulating blocks and spacers
These materials provide electrical separation between windings and the core.
✅️Liquid Insulation – Transformer Oil
Transformer oil plays a dual role:
- Electrical insulation
- Heat transfer medium
High-quality mineral oil ensures:
- High dielectric strength
- Efficient cooling
- Resistance to oxidation
✅️Insulation Coordination
The insulation system is designed to withstand:
- Lightning impulse voltage
- Power frequency voltage
- Thermal stress
Typical insulation level for a 630kVA transformer:
- LI75 AC35
This ensures safe operation even under transient overvoltage conditions.

Transformer oil filling process and insulation materials inside the tank.
Structural Integration of Core, Windings and Insulation System
The efficiency of the internal structure of a 630kVA oil immersed transformer depends on how well the core, windings, and insulation system work together.
Mechanical Assembly
- Core and windings are tightly clamped
- Insulation spacers ensure proper distances
- Assembly is fixed inside the transformer tank
Oil Immersion System
The entire active part (core + windings) is immersed in insulating oil, which:
- Removes heat generated during operation
- Prevents electrical discharge
- Enhances dielectric performance
Thermal and Electrical Balance
A well-designed transformer ensures:
- Balanced magnetic flux distribution
- Controlled temperature rise
- Stable voltage output
This integrated design guarantees long-term reliability and efficient performance in industrial applications.
Typical Technical Parameters of a 630kVA Oil Immersed Transformer
| Parameter | Typical Specification |
|---|---|
| Rated Capacity | 630 kVA |
| Phase | Three Phase |
| Primary Voltage | 10kV / 11kV |
| Secondary Voltage | 0.4kV / 415V |
| Core Material | CRGO Silicon Steel |
| Winding Material | Copper / Aluminum |
| Cooling Method | ONAN |
| Insulation Level | LI75 AC35 |
| Vector Group | Dyn11 |
| No-load Loss | ≤ 980 W |
| Load Loss | ≤ 6200 W |
| Impedance Voltage | 4% – 6% |
These specifications can be customized based on project requirements and international standards.
Conclusion: Why Internal Structure Matters in 630kVA Oil Immersed Transformers
A deep understanding of the Internal Structure of a 630kVA Oil Immersed Transformer-including the core, windings, and insulation system-is essential for ensuring performance, efficiency, and operational safety.
Each component plays a critical role:
- The core determines energy efficiency
- The windings enable power transmission
- The insulation system ensures safety and durability
As a trusted manufacturer, GNEE New Material designs and produces high-performance 630kVA oil immersed transformers with optimized internal structures, ensuring low losses, efficient cooling, and long service life.
If you are planning a transformer procurement project, contact GNEE today to get expert technical support, customized solutions, and a competitive quotation for your 630kVA oil immersed transformer.