500 KVA 11KV Oil Immersed Distribution Transformer
Nov 10, 2025
Leave a message
The rated power of the transformer is 500 KVA. This 500 KVA step down transformer with 3 phase, and the primary voltage is 11KV, the secondary voltage is 0.4KV, the transformer is equipped with no load tap changer, the tapping range is ±2*2.5% at primary side, the cooling is ONAN, the connect group is Dyn11, our 500 KVA power transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.

Technical Specification
500 KVA Oil Immersed Distribution Transformer to Botswana
|
Model |
S11-500 KVA-11/0.4KV |
|
Type |
Oil Immersed Distribution Transformer |
|
Standard |
IEC60076 |
|
Rated Power |
500 KVA |
|
Frequency |
50 HZ |
|
Phase |
Three |
|
Cooling Type |
ONAN |
|
Primary Voltage |
11 KV |
|
Secondary Voltage |
0.4 KV |
|
Winding Material |
Copper |
|
Vector Group |
Dny11 |
|
Impedance |
4% |
|
Tap Changer |
NLTC |
|
Tapping Range |
±2*2.5% |
|
No Load Loss |
0.68KW |
|
On Load Loss |
5.15KW |
|
Accessories |
Standard Configuration |
3 Phase Step Down Power Distribution Transformer applications
- Residential: Supplying power for lighting and other household needs in residential areas.
- Commercial: Powering buildings like shopping centers, hotels, and office buildings.
- Industrial: Providing electricity for light industrial production in factories and other manufacturing facilities.
- Utility: Used in power distribution networks to bring electricity from the main grid to local areas.
- Specialized uses: Can be used in specific locations like airports, subway stations, and some oil and gas platforms.
oil tank:
Corrugated oil tank uses the "corrugated sheet folding machine" in the corrugated production line to automatically fold the specification of cold-rolled steel coil into the sheet type required by the design drawing, including the corrugated height, pitch, corrugated sheet, straight edge length and total length and width of corrugated sheet. The folding quality is good and the speed is fast; the corrugated sheet is welded after folding to complete the folding end seam and reinforced iron welding. The welding adopts argon arc welding, with stable welding arc, large weld penetration, good forming, and no defects. The corrugated oil tank has a bottom, a box edge, and a rectangular mailbox made of corrugated sheets. The corrugated sheet is made of folded sheet. In addition to good heat dissipation performance, the corrugated fin has the function of expansion to relieve the internal pressure rise.
Inspection of distribution transformer before operation:
1. Check the transformer certificate; if the certificate exceeds two months, the insulation resistance should be retested.
2. Check the oil level and breathing hole; there should be no oil leakage, oil leakage and good ventilation.
3. Check whether the high and low voltage insulation bushing and relevant lead wires are intact, and whether the screws are loose.
4. Whether the position of the voltage regulating switch is correct and whether the high and low voltage fuses are suitable.
5. Lightning protection shall be complete and grounding resistance shall be measured to be qualified.
6. There should be no abnormal phenomena in cables and busbars.
What is a distribution transformer usually used for?
A distribution transformer provides the final voltage transformation in the electric power distribution system, stepping down or up the voltage used in the distribution lines to the level used by the customer in their home, businesses, and commercial buildings.
What is the difference between a power transformer and a distribution transformer?
Power transformers perform several functions in high voltage networks that require them to either step up or down the voltage as required. On the other hand, distribution transformers are only used to connect end-users to the power system to facilitate a unidirectional power flow by stepping down the voltage.
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji