1250kVA 22kV Oil Immersed step down Transformer Product Introduction
This 1.25 MVA transformer was delivered to South Africa in 2021 via a South Africa, the rated power of the transformer is 1250 KVA, the primary voltage of the transformer is 22kV, and secondary voltage is 0.4 kV Technical parameters are same as ordinary transformer as no special part. But this transformer has a special paint color. About the color of paint ,Generally we use RAL7035 spray paint, and this transformer is use RAL 7013..The 1250 kVA power transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.

1250 kVA oil immersed power transformer specification and data sheet
|
Delivered to |
South Africa |
|
Year |
2021 |
|
Model |
S-1250kVA-22/0.4kV |
|
Type |
Oil Immersed Power Transformer |
|
Standard |
IEC60076 |
|
Rated Power |
1250 kVA |
|
Frequency |
50 HZ |
|
Phase |
Three |
|
Cooling Type |
ONAN |
|
Primary Voltage |
22 KV |
|
Secondary Voltage |
0.4 KV |
|
Winding Material |
Copper |
|
Vector Group |
Dyn11 |
|
Impedance |
5% |
|
Tap Changer |
NLTC |
|
Tapping Range |
±2*2.5%@primary side |
|
No Load Loss |
1.9 KW |
|
On Load Loss |
15.5 KW |
|
Accessories |
Standard Configuration |
Oil Filled Transformer applications
Power distribution: This is the most common use, where the transformer reduces high voltage to a usable level for industrial facilities, commercial buildings, and residential areas.
Industrial and commercial sites: Applications in places like factories, large office buildings, and shopping centers for power supply and control systems.
General power systems: Used in the broader grid infrastructure for tasks such as power transmission and voltage transformation.
Outdoor applications: Its sealed, oil-immersed design is ideal for outdoor use, such as in pad-mounted or pole-mounted configurations.
Energy-efficient systems: Models with advanced designs, like hermetic, sealed, or corrugated tanks, are used in applications where low loss, low noise, and energy saving are important.
What is the current of 1250 KVA transformer?
Therefore, 1250kva transformer allows 1804A current to work for a long time, and the maximum continuous current is so large, but it is allowed to overload for a short time, and the overload is related to the overload time. The shorter the time, the greater the allowable excess.
What is the impedance of a 1250 KVA transformer?
This document provides the specifications for an oil immersed transformer. It is a 1250 KVA, 3 phase, 50 Hz transformer with a primary voltage of 22000 V and secondary voltages of 400/230 V. It has an impedance voltage of 4% at 75 C, efficiency between 98.08-98.94%, and a noise level below 56 dB.
What is the capacity of oil in a transformer?
The oil capacity of a medium size power transformer with power rating of 10 to 50 MVA is in the range of 5000 to 15000 liters and in a large power transformer with power rating of above 50 MVA you can expect anything from 15000 to 25000 or even 50000 liters of oil.
What is the cost of 1200 kVA transformer?
Three Phase Oil Cooled 1200 Kva Electrical Power Transformer, For Industrial, Input Voltage: 33 Kv at ₹ 850000 in New Delhi.
company profile
GNEE New Material has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE New Material Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE New Material Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji