TYPES OF CAST RESIN TRANSFORMER TESTING
Feb 06, 2024
Leave a message
GNEE New Material cast resin type transformer
A cast resin transformer is a type of transformer that has outstanding features not use liquid to cool the coil but by air.
To make sure the quality and safety operation of the transformer, Users need to check and test them before operation and after operating for a long time. Tests help users easily detect some signs of damage.
Types of Cast Resin Transformer Testing
1. Routine Test
2. Type Test
3. Special Test
Routine Tests of Cast Resin Transformer
Auxiliary wiring insulation test
Dielectric routine tests
Voltage ratio Test
Transformer Ratio Test
Tests on-load tap changers
Winding resistance measurement
No-load loss and current measurement
Short-circuit impedance and load loss measurement
Phase displacement test
PD Measurement
Insulation test and functional verification of accessories
cast resin dry type transformer

Type Tests of Cast Resin Transformer
Temperature-rise type test (IEC 60076-2)
Dielectric-type tests (IEC 60076-3)
Sound level test (IEC 60076-10) for each method of cooling for which a guaranteed sound level is specified
No-load loss and current measurement at 90% and 110% of the rated voltage
Measurement of the power taken by the fan
Special Tests of Cast Resin Transformer
Dissipation factor measurement (tan δ) of the insulation system capacitances
Winding hot-spot temperature-rise measurements
Dielectric special tests (IEC 60076-3)
Determination of capacitances windings-to-earth and between windings
Short-circuit withstand test
Verification of the climatic classes
Detection of harmonic content in the no-load current
Determination of transient voltage transfer characteristics
Zero-sequence impedance(s) measurement on three-phase transformers
Frequency response Measurement (Frequency Response Analysis or FRA); the test procedure shall be agreed between manufacturer and purchaser
D.C. insulation resistance measurement between each winding to earth and between windings
Winding inductance measurement
Check of external coating (ISO 2178 and ISO 2409 or as specified)
Determination of weight with transformer arranged for transport for transformers up to 1,6 MVA by measurement; for larger transformers by measurement or calculation as agreed between manufacturer and purchaser
Thermographic detection of hot-spots
Verification of the behavior to fire classes
The transmitted vibrations measurement
In-rush surges test
Verification of the environmental classes
Test on vibration floor (seismic)
Recurrent voltage surges test
Low-temperature test