Silicon Steel Strip Laminated Cores for Current Transformers: Specifications and Selection

Sep 16, 2025

Leave a message

Why Silicon Steel Strips for Current Transformer Cores

Silicon steel combines a high saturation flux density of approximately 2.0 T (20,000 gauss) with good magnetoelectric properties, low material cost, and suitability for mass production. These characteristics make it the most widely used core material for current transformers, distribution transformers, and reactors in the power electronics industry. The material is relatively insensitive to mechanical stress compared with more brittle magnetic alloys, which simplifies core forming and handling.

Material Selection by Application

The correct grade depends on the duty of the component:

Small motors, reactors, and relays: pure iron or low-silicon steel sheet.

Large motors: high-silicon hot-rolled sheet or non-oriented cold-rolled sheet.

Transformers and current transformers: grain-oriented cold-rolled silicon steel sheet, which offers the lowest core loss and highest permeability along the rolling direction.

Strip Thickness and Operating Frequency

Strip thickness is chosen according to frequency because eddy current loss rises with the square of frequency and strip thickness. For line-frequency operation at 50/60 Hz, a strip thickness of 0.2 to 0.35 mm is common. At 400 Hz, a thickness of about 0.1 mm is preferred. Thinner strips reduce eddy current loss but increase material and processing cost.

Volt-Ampere Characteristics and Accuracy

For a current transformer core, the volt-ampere characteristic at a defined excitation current indicates how much voltage the core can support before saturation. In the table below, the value is measured at 1 A excitation current output. A higher volt-ampere value at a given core size means the core can maintain linearity to a higher secondary burden, which supports the accuracy classes defined in IEC 61869-2.

Core Specification Table

Table 1 lists standard sizes with the effective cross-sectional area, weight, volt-ampere characteristic, and magnetic circuit length.

Size d*D*B (mm) Cross-section (mm2) Weight (g) Volt-ampere (mV) at 1 A Magnetic path (mm)
184*226*60 1260 7096 7.6 643.7
52.5*90.5*64 1216 2388 27.2 224.5
57*89*58 928 1861 17.3 229.2
55*81*68 884 1651 29.3 213.5
59*89*53 795 1616 19.8 232.4
55*87*40 640 1248 19.8 222.9
60*88*40 560 1139 13.8 232.4
41*72*25 387.5 602 14.1 177.4
62*82*30 300 593 8.8 226.1
24*35*10 55 45 3.1 92.6

Custom sizes are produced by adjusting the strip width, build height, and winding tension to meet the ratio and burden requirements of the instrument transformer specification. The HS code for such laminated cores is 8504909090.

Rust Prevention by Passivation

Silicon steel cores are protected by a chemical passivation treatment based on a redox reaction. A strong reducing agent reduces metal ions in solution and deposits a dense metal film on the surface of the core. The solid protective film adheres firmly, cannot be diluted, does not react easily with impurities in the air, and provides long service life in humid environments.

Frequently Asked Questions

Why is grain-oriented silicon steel used for current transformer cores?

Grain-oriented cold-rolled steel has lower core loss and higher permeability along the rolling direction, which gives the low magnetizing current and high linearity required for accurate current transformation.

What strip thickness should be used at 400 Hz?

At 400 Hz, a strip thickness of about 0.1 mm is typically chosen to limit eddy current loss, whereas 0.2-0.35 mm is common for 50/60 Hz operation.

What does the volt-ampere characteristic tell the designer?

It shows the maximum secondary voltage the core can develop at a given excitation current before saturation, which determines the accuracy limit factor and allowable burden of the current transformer.

What is the saturation flux density of silicon steel?

Silicon steel saturates at approximately 2.0 T (20,000 gauss), which is higher than ferrite, amorphous, or nanocrystalline materials and is the main reason it remains the standard for current transformer cores.

How is rust prevented on laminated silicon steel cores?

A passivation treatment deposits a dense metal film on the core surface, sealing it against moisture and air while keeping the coating thin enough not to affect the magnetic circuit.

Can one core size cover different current transformer ratios?

Yes. The ratio is set by the number of secondary turns, so a given core size can serve multiple ratios as long as the volt-ampere characteristic and magnetic path length meet the accuracy and burden requirements.