S13 160kVA Three-Phase Oil-Immersed Power Distribution Transformer
Oct 31, 2025
Leave a message
The S11/13-M series fully sealed oil immersed power transformers developed and produced by our company have the advantages of low loss, low noise, and high efficiency, which can achieve good energy-saving effects and reduce pollution. Compared with ordinary oil immersed transformers, fully sealed transformers eliminate oil storage tanks, and the change in oil volume is automatically adjusted and compensated by the elasticity of the corrugated sheets in the corrugated oil tank. The transformer is isolated from air to prevent and slow down oil degradation and insulation aging, enhance operational reliability, and operate normally without maintenance.


Three-Phase Oil-Immersed Transformer Product Features
The transformer core is made of imported high-quality cold-rolled silicon steel sheets stacked together, which greatly reduces the no-load loss and no-load current, and the core is tied to ensure the tightness of the core and reduce noise.
High and low voltage windings are wound with oxygen-free copper, low voltage winding 500kVA and below adopts double-layer cylindrical structure, 630kVA and above adopts double-helix or quadruple-helix structure, and high-voltage winding adopts multi-layer cylindrical structure.
Transformer linkage adopts Dyn11, reducing the impact of harmonics on the power grid and improving the quality of power supply.
Transformer is fully sealed structure, prolonging service life, free of lifting centre, free of maintenance, and the measured noise is lower than the standard.
Oil-filled Transformer Product Parameters
|
S11/13/20/22 Oil-immersed power transformer |
|||||||||
|
Capacity (KVA) |
Voltage Ratio |
Vector Group |
LWA |
No Load Loss (W) |
Load Loss At 75℃ (W) |
No Load Current (%) |
Impedance 75℃ (%) |
||
|
High Voltage (KV) |
HV Tapping % |
Low Voltage (KV) |
|||||||
|
100 |
6 |
±2×2.5% or +3/-1×2.5% |
0.4 |
Dyn11 |
52 |
75 |
1500 |
1 |
4 |
|
125 |
54 |
85 |
1800 |
0.9 |
|||||
|
160 |
100 |
2200 |
0.7 |
||||||
|
200 |
56 |
120 |
2600 |
0.7 |
|||||
|
250 |
140 |
3050 |
0.7 |
||||||
|
315 |
58 |
170 |
3650 |
0.7 |
|||||
|
400 |
200 |
4300 |
0.5 |
||||||
|
500 |
60 |
240 |
5150 |
0.5 |
|||||
|
630 |
320 |
6200 |
0.3 |
4.5 |
|||||
|
800 |
62 |
380 |
7500 |
0.3 |
|||||
|
1000 |
450 |
10300 |
0.3 |
||||||
|
1250 |
65 |
530 |
12000 |
0.2 |
|||||
|
1600 |
630 |
14500 |
0.2 |
||||||
|
2000 |
67 |
750 |
17400 |
0.2 |
5 |
||||
|
2500 |
900 |
20200 |
0.2 |
||||||
Usage conditions
2. Minimum ambient temperature: -25 ºC
Altitude:<1000m3
A. Maximum monthly average relative humidity: 90% (20 ºC) 5. Installation location: Installed in a place without fire, explosion hazard, serious pollution, chemical corrosion, and severe vibration, indoors or outdoors.
company profile
GNEE New Material has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE New Material Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE New Material Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji