Three Phase Oil-Immersed Transformer Product features
1. The transformer core is made of high-quality cold-rolled silicon steel sheets,which is tensioned by steel tension belt, forms a
solid frame structure with the clamp. The layers gap is small, and the joints of each layer are staggered, which greatly reduces
the no-load loss and current and noise.
2.The transformer coil adopts high-purity oxygen free copper, which effectively reduces the copper loss; The cushion block and
brace are rounded, the electric field is uniform, and the reliability is enhanced. The inner winding support is strengthened to improve
its stability and prevent instability and deformation, and improve the short-circuit resistance of the transformer.
3.The transformer is fully sealed and free for maintenance to prolong usage life to more than 30 years.
Oil-filled Transformer Products specification
Rated Capacity:250KVA
Rated voltage ratio: 35kV / 0.4kV
Impedance voltage: 6.5%
No load loss: 410w
Load loss: 3770w
Oil weight: 580kg
Body lifting weight: 830kg
Total weight: 1720kg
Dimensions (L*W*H):1750*1150*2020
|
S11/13/20/22 Oil-immersed power transformer |
|||||||||
|
Capacity (KVA) |
Voltage Ratio |
Vector Group |
LWA |
No Load Loss (W) |
Load Loss At 75℃ (W) |
No Load Current (%) |
Impedance 75℃ (%) |
||
|
High Voltage (KV) |
HV Tapping % |
Low Voltage (KV) |
|||||||
|
100 |
6 |
±2×2.5% or +3/-1×2.5% |
0.4 |
Dyn11 |
52 |
75 |
1500 |
1 |
4 |
|
125 |
54 |
85 |
1800 |
0.9 |
|||||
|
160 |
100 |
2200 |
0.7 |
||||||
|
200 |
56 |
120 |
2600 |
0.7 |
|||||
|
250 |
140 |
3050 |
0.7 |
||||||
|
315 |
58 |
170 |
3650 |
0.7 |
|||||
|
400 |
200 |
4300 |
0.5 |
||||||
|
500 |
60 |
240 |
5150 |
0.5 |
|||||
|
630 |
320 |
6200 |
0.3 |
4.5 |
|||||
|
800 |
62 |
380 |
7500 |
0.3 |
|||||
|
1000 |
450 |
10300 |
0.3 |
||||||
|
1250 |
65 |
530 |
12000 |
0.2 |
|||||
|
1600 |
630 |
14500 |
0.2 |
||||||
|
2000 |
67 |
750 |
17400 |
0.2 |
5 |
||||
|
2500 |
900 |
20200 |
0.2 |
||||||
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji