11/0.415kv 200kVA Outdoor Type Oil Immersed Distribution Transformer
Oct 31, 2025
Leave a message


Oil Immersed Distribution Transformer Feature
1.The Iron Core is Made By Crystal Grain-Oriented Silicon-Steel Sheet;Fold The Sheet Into A Multistage Roll Cross-Section To Reduce The Noise And Power Consumption
2.Cylinder Type For High Voltage or Foil Type For Low Voltage; Can Increase The Ability To Resist Short Circuit And Strike; And The Distribution of Magnetic Path Is More Rational
3.The Oil Tank is Made By Fine Cold-Rolled Steel Sheets; Georg Corrugation Oil Tank Production-Line Is Adopted; The Isolation From Air Guarantees A Low Aging Speed Of Oil And A Long Life Expectancy Of Transformer.
4.Oil-Immersed Distribution Transformer Adopts A-Level Insulation Structure
Oil Filled Transformer Product Parameters
| Pated Capacity |
Voltage Combination |
Vector Group |
No-load Loss |
Load Loss |
No-load Current |
Impedice Voltage |
Total Weight |
Exterior Size | Installation center /Installaton hole |
||
| (kVA) | High voltage(kV) | Tap range | Low voltage(kV) | (W) | (W) | (%) | (%) | (kg) | (L*W*H)(mm) | (mm) | |
| 30 | 6 6.3 10 10.5 11 |
±5% or ±2*2.5% |
0.4 | Ydn0 or Dyn11 |
100 | 630/600 | 1.8 | 4.0 | 335 | 1030*690*860 | 400*400/4*ф14 |
| 50 | 130 | 910/870 | 1.6 | 410 | 1045*700*925 | 400*400/4*ф14 | |||||
| 63 | 150 | 1090/1040 | 1.5 | 460 | 1075*710*940 | 400*400/4*ф14 | |||||
| 80 | 180 | 1310/1250 | 1.4 | 490 | 1080*715*995 | 400*400/4*ф19 | |||||
| 100 | 200 | 1580/1500 | 1.3 | 550 | 1110*730*1020 | 400*400(550)/4*ф19 | |||||
| 125 | 240 | 1890/1800 | 1.2 | 615 | 1135*740*1035 | 400*400(550)/4*ф19 | |||||
| 160 | 280 | 2310/2200 | 1.1 | 695 | 1155*755*1050 | 550*550/4*ф19 | |||||
| 200 | 340 | 2730/2600 | 1 | 790 | 1200*770*1075 | 550*550/4*ф19 | |||||
| 250 | 400 | 3200/3050 | 0.9 | 930 | 1240*800*1100 | 550*550/4*ф19 | |||||
| 315 | 480 | 3830/3650 | 0.8 | 1110 | 1305*840*1120 | 550*550/4*ф19 | |||||
| 400 | 570 | 4520/4300 | 0.7 | 1290 | 1390*900*1160 | 660*660/4*ф19 | |||||
| 500 | 680 | 5410/5150 | 0.7 | 1510 | 1500*990*1195 | 660*660/4*ф19 | |||||
| 630 | 810 | 6200 | 0.6 | 4.5 | 1730 | 1580*1030*1305 | 660*660/4*ф19 | ||||
| 800 | 980 | 7500 | 0.6 | 2075 | 1705*1140*1360 | 820*820/4*ф19 | |||||
| 1000 | 1150 | 10300 | 0.5 | 2490 | 1730*1290*1395 | 820*820/4*ф19 | |||||
| 1250 | 1360 | 12000 | 0.4 | 2960 | 1780*1320*1480 | 820*820/4*ф19 | |||||
| 1600 | 1640 | 14500 | 0.4 | 3515 | 1890*1430*1520 | 820*820/4*ф19 | |||||
| 2000 | 1940 | 18300 | 0.4 | 5.0 | 4880 | 2050*1360*1840 | 820*820/4*ф19 | ||||
| 2500 | 2290 | 21200 | 0.4 | 6010 | 2170*1430*2015 | 1070*1070/4*ф19 | |||||
Customization Optional
200kVA Oil Immersed Transformer
GNEE's three-phase oil-immersed transformers can be fully customized to meet your specific requirements.
The optional specifications of 200 kVA three-phase oil-immersed transformers provide a variety of customized options to meet the needs of different application scenarios. Users can choose different input and output voltage levels according to actual needs, such as 10kV/0.4kV, 11kV/0.4kV, etc., to adapt to different power distribution requirements. The insulation level and cooling method of the transformer can also be adjusted according to the use environment, such as providing natural oil cooling or a forced oil cooling system to optimize the heat dissipation effect. To improve safety and reliability, temperature monitoring devices, overload protection systems, and short circuit protection functions are also optional.
In addition, the transformer can also be customized according to noise requirements, providing a low-noise design, suitable for noise-sensitive environments. Anti-corrosion coating and moisture-proof protection are also optional configurations for severe weather and environmental conditions. With these optional specifications, the 200 kVA oil-immersed transformer can flexibly respond to various industrial, commercial and residential power needs.
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji