Low Iron Loss CRNGO Motor Lamination Steel
Sep 29, 2025
Leave a message
What Is CRNGO Electrical Steel?
Cold rolled non-grain-oriented silicon steel (CRNGO) is an electrical steel alloy containing controlled amounts of silicon (typically 1.5-3.5%) and carbon, processed so that the magnetic properties are isotropic, meaning nearly equal in all rolling directions. After cold rolling and annealing, CRNGO strip shows low core loss, high magnetic induction, and good punching characteristics, which makes it the standard material for rotating machines such as motors and generators.
Key Advantages of Low Iron Loss CRNGO Steel
Low iron loss (core loss) for higher machine efficiency.
High magnetic induction for compact designs.
Uniform thickness and small thickness deviation for consistent stacking.
Good punchability, extending die life in high-volume stamping.
High lamination factor, increasing the effective cross-section of the core.
Stable magnetic performance and good corrosion resistance.
Grade Designations and Electromagnetic Properties
Grades are designated according to GB/T 2521.1-2016 and IEC 60404-8-4, where the number indicates the maximum specific total loss at 1.5 T / 50 Hz in W/kg (P15/50). The table below lists typical high-efficiency series values.
| Grade | Nominal thickness (mm) | Theoretical density (kg/dm3) | Core loss P15/50 (W/kg) | Magnetic induction B50 (T) |
|---|---|---|---|---|
| 35SWH250 | 0.35 | 7.65 | 2.40 | 1.69 |
| 50SWH470 | 0.50 | 7.70 | 3.05 | 1.72 |
| 50SWG470 | 0.50 | 7.75 | 3.15 | 1.73 |
| 50SWH600 | 0.50 | 7.75 | 3.60 | 1.74 |
Standard Compliance and Supply Forms
CRNGO steel is supplied in coil or sheet form, with thickness from 0.20 mm to 0.50 mm and width from 20 mm to 1250 mm, or as required. The surface treatment is an insulating coating. Grades and property limits follow GB/T 2521.1-2016, and testing methods follow GB/T 2522 and IEC 60404-2. Semi-processed grades are available for customers who perform stress relief annealing after stamping.
Applications
CRNGO electrical steel is used in AC motors, generators, small transformers, ballasts, reactors, and other rotating electrical machines where isotropic magnetic properties are required.
Processing Considerations
For motor lamination stamping, maintain sharp dies and controlled clearance to avoid burrs that reduce the lamination factor. If the design specifies stress relief annealing after stamping, follow the recommended temperature and atmosphere to restore magnetic properties without damaging the insulation coating.
Frequently Asked Questions
Q: What does CRNGO stand for?
CRNGO means cold rolled non-grain-oriented electrical steel. The magnetic properties are nearly the same in all directions, unlike grain-oriented (CRGO) steel, which is anisotropic.
Q: What is the difference between CRNGO and CRGO?
CRGO has a preferred grain orientation and extremely low losses along the rolling direction, so it is used for transformer cores; CRNGO is isotropic and is used for motors and generators where the flux rotates.
Q: How is the grade number interpreted?
In GB/T 2521.1-2016 designations such as 35SWH250, the number relates to the maximum specific total loss at 1.5 T / 50 Hz (W/kg), with prefixes indicating thickness and series.
Q: Can CRNGO steel be laser cut?
Yes, laser cutting is common for prototypes, but the heat-affected zone can slightly increase edge loss. For mass production, stamping is preferred for cost and edge quality.
Q: Why is a high lamination factor important?
A higher lamination factor means a larger share of the stack cross-section is steel rather than coating and air, increasing flux-carrying capacity and reducing the required stack height.
Q: In what forms is low iron loss CRNGO steel supplied?
It is supplied as full coils, slit strip and cut-to-length sheets, normally with an insulation coating already applied, in the thickness range used by motor and generator laminations. Strip width and coil weight are matched to the customer punch or press line, and thinner gauges are selected as the operating frequency rises so that eddy current loss in the lamination is kept under control.