CRGO Grain-Oriented Silicon Steel Lamination for Transformer Cores

Sep 29, 2025

Leave a message

CRGO grain-oriented silicon steel lamination is the thin, cold-rolled sheet material used to build the magnetic circuit of power and distribution transformers. Its crystal grains are deliberately aligned with the rolling direction, so the easy axis of magnetization follows the flux path. That single metallurgical feature is why a grain-oriented lamination core reaches far lower core loss than a random-grain sheet of the same mass.

Because the core is stacked from individual sheets instead of being cast as one solid block, eddy currents are broken into narrow loops between insulated surfaces. Hysteresis loss and eddy loss, the two mechanisms that dominate transformer heating, are both held down, which gives a cooler, quieter and more efficient core at any given kVA rating.

What Makes a Lamination Grain Oriented

Three production stages separate CRGO from ordinary electrical steel:

Silicon alloying - silicon content is raised to about 2.9–3.3 % by mass, which lifts electrical resistivity and suppresses eddy current loss.

Cold rolling and recrystallization - heavy cold reduction followed by primary and secondary recrystallization develops the Goss texture, the preferred grain orientation that gives the sheet strongly directional permeability. Carrying flux along the rolling direction needs far less exciting current than crossing it.

Insulating coating - a phosphate or oxide based layer is applied and cured so adjacent laminations remain electrically isolated after shearing and stacking.

Magnetic Properties That Decide Core Performance

Property Effect on the finished core
High magnetic permeability The core magnetizes with a small exciting current and low reactive demand
High electrical resistivity Eddy currents are restricted, so less energy is dissipated as heat
Low core loss Lower no-load loss and lower temperature rise in service
High stacking factor More active magnetic material inside the same core window
Uniform coating adhesion Interlayer insulation survives slitting, punching and clamping

CRGO Grades and How to Read the Designation

In the GB/T 2521 designation used for these laminations, the leading pair of digits gives nominal thickness in hundredths of a millimetre and the trailing digits give maximum specific total loss at 1.7 T and 50 Hz multiplied by 100. A grade written as 23Q110 is therefore a 0.23 mm sheet with a guaranteed loss of about 1.10 W/kg.

Grade Nominal thickness Loss class at 1.7 T / 50 Hz
23Q080 0.23 mm 0.80 W/kg
23Q085 0.23 mm 0.85 W/kg
27Q100 0.27 mm 1.00 W/kg
27Q110 0.27 mm 1.10 W/kg
27Q120 0.27 mm 1.20 W/kg

Grade selection balances no-load loss targets, core building time and material budget; where the design needs the highest possible flux density rather than the lowest loss, high-induction and domain-refined grades of the same thickness family are used.

From Mill Coil to Stacked Core

Coil selection - grade, thickness and coating type are fixed against the transformer design sheet.

Slitting - the coil is cut to the required strip width, with burr height controlled to avoid interlayer shorts.

Punching and shearing - laminations are cut to profile, including mitred and step-lap joint geometries.

Stress relief annealing - punched or wound parts are annealed to remove punching and bending strain before assembly.

Stacking - sheets are interleaved and clamped to the specified stacking factor and window dimensions.

Testing - core loss, exciting current and dimensional checks confirm the finished core before dispatch.

Dimensional and Supply Options

Parameter Typical range
Nominal thickness 0.23 mm, 0.27 mm, 0.30 mm and 0.35 mm sheet
Thickness tolerance plus or minus 10 % of nominal
Strip width slit to width from mill coil, up to 1200 mm
Surface condition insulation coated on both faces, cold rolled finish
Supplied form cut sheet, slit strip, punched lamination or assembled clamped core
Cut profile straight cut, mitred cut, step-lap and wound ring section

Distribution and power transformers remain the largest application, followed by instrument transformers, inductors, reactors and the magnetic packs of larger motors and generators. The common requirement is a magnetic circuit that carries flux in one direction and in one plane, which is the duty a grain-oriented lamination serves best. Where the flux path rotates or runs in several directions at once, non-oriented grades are used instead, because the advantage of grain orientation is lost.

Frequently Asked Questions

Q: What thickness of CRGO lamination is normally specified?
0.23 mm to 0.35 mm sheet covers most transformer work. The 0.23 mm and 0.27 mm grades are chosen where no-load loss targets are tight, while thicker sheet reduces stacking labour and material cost.

Q: Why is the sheet coated before stacking?
The coating provides interlayer insulation. Without it, adjacent sheets would form a conductive path and eddy currents would circulate through the whole stack instead of being confined to each thin sheet.

Q: Can laminations be produced to a custom profile?
Yes. Slitting, straight shearing, mitred cutting, step-lap profiles and wound ring sections are produced to drawing, with the joint geometry matched to the core clamping method and the available press capacity.

Q: Does the rolling direction matter during stacking?
It matters a great deal. Permeability is highest along the rolling direction, so laminations are oriented so the main flux path follows it. Cross-grain flux raises exciting current sharply.

Q: What determines the stacking factor of a finished core?
Coating thickness, burr height, sheet flatness and clamping pressure. A high stacking factor means more active steel inside the core window and a smaller core for the same rating.

Q: How is core loss verified on a completed core?
Assembled cores are tested for specific total loss and exciting current at the design flux density and frequency, together with dimensional checks on window height, window width and joint gap.

Send Inquiry