Premium 2500 KVA Oil-Immersed Transformer for Power Distribution

 

The 2500 KVA Three Phase Oil Filled Distribution Transformer is a robust and high-performance solution designed for medium voltage distribution networks. It ensures efficient voltage transformation from 35kV to low voltage levels such as 380V, 400V, or 415V, making it suitable for industrial, commercial, and public utility applications.

 

Manufactured using high-quality copper windings, silicon steel or amorphous alloy cores, and advanced insulation materials, this Filled Distribution Transformer delivers low loss, high efficiency, and long service life. It meets international standards including IEC, ANSI, and IEEE, making it a reliable choice for global markets.

 

Key Features

Rated Capacity: 2500 KVA

Voltage Levels: 35kV / 0.4kV (customizable)

Cooling: ONAN (Oil Natural Air Natural)

Efficiency: Meets GB20052-2013 Level 1

Overload Capacity: 120% for 2 hours

Noise Level: ≤ 45 dB(A)

Its compact design and reliable thermal management make it ideal for indoor and outdoor installations, including hospitals, factories, data centers, and renewable energy plants.

 

2500 KVA Three Phase Oil Filled Transformer

 

2500 KVA Three Phase Oil Filled Transformer Technical Specification

Parameter Value / Specification
Rated Power 2500 KVA
Place of Origin China
Model Oil Immersed Transformer
Number of Phase Three Phase
Coil Number Three
Winding Type Multi-winding Transformer
Standard Compliance IEC, ANSI, IEEE, CCC
Core Shape Ring Core
Usage Power Distribution
High Voltage 35kV
Low Voltage 380V / 400V / 415V / 440V (custom)
Tapping Range ±2×2.5%
Impedance Voltage 0.04
Load Loss 2.6 ~ 2.73 kW
No-load Loss ≤ 0.1% of rated power
No-load Current 0.6
Frequency 50Hz / 60Hz
Cooling Method ONAN
Connection Group Dyn11 / Yyn0 / Yd11 / YNd11
Coil Material 100% Copper (Aluminum optional)
Transformer Weight 300 ~ 2000 kg (varies by configuration)

 

Accessories & Optional Components

To enhance performance, safety, and serviceability, the transformer supports the following components:

  • Buchholz Relay: Fault detection via gas and oil surge monitoring
  • Oil Temperature Indicator (OTI): Real-time oil temperature feedback
  • Winding Temperature Indicator (WTI): Overheating protection
  • Pressure Relief Device: Explosion prevention via pressure release
  • Magnetic Oil Level Gauge: Accurate oil level monitoring
  • Radiators / Cooling Fins: Optional forced-air fans for heavy-duty cooling
  • On-load / Off-load Tap Changer: Voltage regulation adaptability
  • Earthing Terminals & Surge Arresters: Ensuring safety under faults or lightning
  • Breather with Silica Gel: Moisture protection for the conservator tank

 

2500 KVA Oil type Transformer Application

The 2500 KVA three phase oil filled transformer is suitable for:

Hospitals (e.g., Mendoza Hospital Case Study in Argentina)

Industrial factories and processing plants

Commercial complexes and high-rise buildings

Data centers and IT infrastructure

Solar or wind energy hybrid grid stations

Rural electrification and public utility grids

 

In one application, a large medical center in Argentina deployed this model with a forced-air cooling system and emergency switching. The transformer's stability ensured uninterrupted power for critical care units and hospital operations.

 

Warranty & Service Life

Standard Warranty: 2 years (extendable)

Expected Lifespan: 25–40 years

Maintenance Tip: Scheduled testing and thermal diagnostics can extend service life by 30%+

 

Price Factors for 2500 KVA Oil Transformers

Several variables influence the total cost:

Component Options & Impact on Price
Core Material Amorphous Alloy (cost↑, efficiency↑), or Silicon Steel
Winding Material Copper (durability↑, price↑) or Aluminum (budget-friendly)
Accessories International Brands (ABB, Schneider) cost more
Efficiency Compliance

DOE 2016 & GB20052 compliance may increase cost 30%

 

 

company profile


 

GNEE TRANSFORMER has strong production capacity and an efficient marketing team.

 

Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,

 

Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.

 

GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.

 

transformer Workshop equipment display


 

Transformer Test equipment
Test equipment
Transformer Test equipment2
Test equipment

 

Oil transformation workshop
Oil transformation workshop
Dry transformation workshop
Dry transformation workshop

 

Transformer Intelligent automatic bending machine
Intelligent automatic bending machine
Transformer Cnc punch press
Cnc punch press

 

Transformer Intelligent laser cutting machine
Intelligent laser cutting machine
Transformer Welding robot
Welding robot

 

Transformer Fully automatic laminating unit
Fully automatic laminating unit
Transformer Fully automatic laminating unit2
Fully automatic laminating unit

 

Transformer Wire winding unit
Wire winding unit
Transformer Wire winding unit2
Wire winding unit
Transformer Wire winding unit3
Wire winding unit

 

 

 

 

types of transformer from GNEE


 

500kV oil-immersed single-phase double-winding unexcited voltage regulating power transformer

500kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
220kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
66kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
66kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
35kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
35kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
10kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
S(B)H15(21~25)-M sealed amorphous alloy power transformer
SCB three-dimensional core transformer
35kV dry-type non-excitation voltage regulating power transformer
35kV dry-type on-load voltage regulating power transformer
35kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side without excitation voltage regulation
20kV dry-type non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side
SC(B)H15(17~19) amorphous alloy dry type transformer
SG(B)12~18 non-encapsulated H-class dry type transformer
CSD marine transformer
SGB three-dimensional core transformer
New energy transformer
35kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
10kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
Prefabricated cabin substation
Integrated inverter and step-up converter
10000V mine transformer
6000V mine transformer
Buried transformer
Phase-shifting rectifier transformer
Electric furnace transformer
Grounding transformer
QSG/SG three-phase dry isolation transformer
Three-phase pad-mounted transformer
Single-phase pad-mounted transformer
Single-phase pole-mounted transformer

Get Transformer Order specification

GNEE Transformer Order specification

When choosing our company's products, please provide the following data to better serve you.

Demander

Demander:

Telephonemethods:

Fax:

Project technical leader:

Telephonemethods:

Mailbox:

Transformer type selection

□Dry transformer

{□SC(B) Epoxy resin □SC(B) Non-encapsulated}

□American Box(ZGS)

{□Terminal type(-Z-) □Ring network type(-H-)}

□European Box change(YBM){□ Dry change □Oil change}

□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow}

□Amorphous alloy transformer{□Dry amorphous □ Oil amorphous}

□ Special transformer{Rectifier, Furnace, Mine, Etc}

Transformer basic data selection

Country of use:

 

Phase number:

□Three-phase(S conventional) □ Monophase □Other( )

Frequency:

□50Hz(conventional) □60Hz □ Other( )

Transformer oil:

□#25(conventional) □#45(minimum temperature below-25℃)

Rated capacity:

□( )kVA Conditions of use □Outdoor type □Indoor type

Altitude:

□Less than 1000m(conventional) □1000-2000m □3000m以上 over

Rated voltage(High voltage)

□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( )

Rated voltage(Low pressure)

□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( )

Connected group

□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( )

Impedance(%):

□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( )

Voltage regulation mode

□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z)

Voltage regulation range

□±2*2.5% □±5% □±3*2.5% □Other( )

Transformer accessory selection

□Fan □Temperature control{□ Common □With 485 computer interface}

□Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel}

□Protection level of dry case(□IP20(Conventional) □IP( )}

□Dry case height requirements{□None □Requirements[ ]}

□ Cable out mode of the dry variable shell

{□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]}

Note:

1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged

2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee)

Other special requirements(additional charges apply below)

Dry transformer

□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo

□Zero sequence transformer □Copper bar to the low voltage cabinet

□Protective mesh □Lighting □100kVA or less Fan □Shock absorber

Oil-immersed transformer

□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator

□400kVA and below low voltage outlet OABC phase with wiring terminals

□630kVA or below requires temperature control

□800kVA or below Low voltage outlet phase 0 requires wiring terminals

□630kVA and below must be equipped with gas relay

 

GNEE TRANSFORMER Industrial Layout


 

Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan

 

Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa

 

North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica

 

Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom

 

South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile

 

Middle East: The Middle East region

 

Oceania: Australia, Papua New Guinea. Fiji

Send Inquiry