2500 KVA Three Phase Oil Filled Distribution Transformer
Nov 07, 2025
Leave a message

Introduction of 2500 KVA Three Phase Oil Filled Distribution Transformer
Primary Voltage:33KV 35KV
Secondary Voltage:0.38KV 0.4KV 0.415KV 0.44KV
Connection Type: Dyn11/Yyno or others
Standards: ANSI/IEEE CSA/CAN DOE
Power Rating: 2500 KVA
Certificate: CSA SGS CE UL cUL
In 2018, two 2500 KVA transformers were exported to Argentina in South America, with a rated capacity of 2500 KVA, a primary voltage of 20 KV, and a secondary voltage of 0.4 KV. These two transformers are used for local public utilities. The products have been specially customized, including enhanced insulation systems, additional cooling capacity, and seismic design to ensure long-term stable operation under the complex local climatic conditions and geological environment. The two transformers are currently operating normally, fulfilling Evernew Transformer's commitment to high quality and stable operation of transformers.
2500 KVA Transformer Technical specifications
2500 KVA Three Phase Oil Filled Transformer Specification and Data Sheet
| Place of Origin | China |
|---|---|
| Model Number | Oil immersed transformer |
| Number of Phase | Three Phase |
| Coil Number | Three |
| Winding Type | Multi-winding Transformer |
| Standard | IEC ANSI IEEE CCC |
| Shape of Core | Ring |
| Usage | Power Transformer |
| Rated Capacity | 2500 KVA |
| High Voltage | 35kV |
| Low Voltage | 380v/400v/415v/440v |
| Tapping Range | ±2×2.5% |
| Impedance Voltage | 0.04 |
| Load Loss | 2.73/2.6kW |
| No-load Loss | 2560 |
| No-load Current | 0.6 |
| Frequency | 50Hz/60Hz |
| Connection Group | Dyn11/Yyn0/Yd11/YNd11 |
| Cooling Method | ONAN |
| Coil Material | 100%Copper |
| Winding Material | CopperAluminum |
Main Features of 2500 KVA Oil immersed transformer
-
High Efficiency and Energy Saving, Low Loss
No-load Loss: ≤ 0.1% (relative to rated power)
Load Loss: ≤ 0.5% (relative to rated power)
Energy Efficiency Level: Meets the Level 1 energy efficiency standard of GB20052-2013
-
Strong Overload Capability
Overload Capacity: Can operate at 120% of rated load for 2 hours without cooling
Short-circuit Voltage: 6% ± 0.5%
-
Stable Operation and Low Noise
Noise Level: ≤ 45 dB(A)
Operating Temperature Rise: ≤ 65°C (relative to ambient temperature)
Vibration Coefficient: ≤ 2.5 mm/s
-
Compact Structure, Easy to Install and Maintain
Dimensions: Length × Width × Height (specific dimensions vary by model)
Weight: 300 kg – 2000 kg (varies by model)
Cooling Method: Natural air cooling/forced air cooling (customizable based on requirements)
2500 KVA oil Transformer Application
The 2500 KVA three phase oil filled distribution transformer finds extensive application across various sectors such as industrial, commercial, public utilities, and agriculture. It provides stable and efficient power support to different users, promoting stable development across various industries.
Case in Point: A Large Hospital in Mendoza, Argentina
A large hospital in Mendoza, Argentina, needs to ensure a stable power supply for its various medical equipment and facilities to avoid any interruptions that could affect patient care. By choosing the 2500 KVA three phase oil filled distribution transformer, the hospital guarantees a stable power supply.
Implementation:
Strategic Placement: The transformer is strategically installed in the hospital's power center with emergency power switching devices.
Cooling System: A forced air cooling system is employed to ensure reliable operation under any circumstances.
This setup enhances the hospital's service quality by providing a consistent and reliable power supply, ensuring that all medical equipment functions optimally without power-related disruptions.
This transformer's versatile applications and reliable performance make it an ideal choice for various sectors, contributing significantly to the stable development of industries.
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji