220kVA Oil Transformers for Heavy-Duty Applications
Nov 05, 2025
Leave a message
The 220kVA Oil Immersed Transformer is a reliable and efficient power distribution device designed for industrial, commercial, and infrastructure applications. It utilizes mineral oil or eco-friendly insulating oil for cooling, enabling stable voltage conversion (e.g., 10kV to 0.4kV). Built with robust materials and advanced technology, it offers long service life, low maintenance, and adaptability to harsh environments.

Oil Immersed Transformer Structural Features
Core
High-permeability cold-rolled silicon steel strips with layer insulation to minimize eddy current losses.
Three-phase five-limb design to reduce zero-sequence impedance and suppress harmonics.
Windings
High Voltage Winding: Copper foil wound with Nomex paper interlayer insulation.
Low Voltage Winding: Multi-layer cylindrical structure for enhanced short-circuit resistance.
Tank and Cooling
ONAN design with natural oil circulation and no external fans, ideal for outdoor installation.
Corrugated radiator fins integrated into the tank for efficient heat dissipation.
Insulation System
Mineral oil (or eco-friendly ester oil) provides insulation, cooling, and arc extinction.
Partial discharge level ≤50pC (IEC 60076 compliant).
Oil Immersed Transformer Product Parameters
| Items | Item |
| Production Descriptions | Oil-Immersed Transformer |
| Reference standards | IEC 60076-11 |
| Capacity | 50-2500kVA or Customized |
| Frequency | 60 / 50Hz |
| Voltage (HV) | 22KV or customized |
| Voltage (LV) | 0.4KV or customized |
| Impedance | 4% |
| Connections (Vector Group) | Dyn11 |
| Tapping Range | ±2×2.5% |
| Core materials | Silicon Steel |
| Winding materials | Aluminum or copper |
| Lightning Impulse Withstand Voltage | IEC standard |
| AC withstand voltage | IEC standard |
| Temperature Rise class | H-class |
| Temperature Rise | 125K |
| Cooling method | AN/AF |
| Delivery Capacity | 300 units per month |
Oil Filled Transformer Applications
- Industrial Power Distribution
Medium-voltage distribution (10kV to 0.4kV) in factories, mines, and metallurgical plants.
Supports short-term overload (e.g., electric furnaces, motor startups).
- Commercial Buildings
Power distribution for malls, office towers, and hotels.
- Infrastructure
Railway stations, airports, and wastewater treatment plants.
- Remote Areas
Operates reliably in high humidity, dusty, or temperature-fluctuating environments.
Oil Filled Transformer Key Advantages
High Reliability
Fully sealed tank prevents oil oxidation and contamination.
Strong short-circuit withstand capability (GB/T 1094.5 compliant).
Low Maintenance
Maintenance-free design with real-time oil level and temperature monitoring.
Cost-Effective
Low initial investment and minimal operational energy losses.
Eco-Friendly Options
Available with biodegradable ester oil (e.g., FR3) for RoHS compliance.
company profile
GNEE New Material has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE New Material Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE New Material Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji