A 1000 kVA oil-immersed transformer is a medium-to-large capacity transformer that uses mineral oil for insulation and cooling, commonly used in industrial sites, factories, and substations to step down medium-voltage power to a lower voltage for distribution. These three-phase transformers are designed for durability and efficiency, featuring robust, oil-filled tanks that enhance heat dissipation, protect against moisture and fire, and meet specific environmental and safety standards. They are built to provide a reliable and stable power supply with features like overload protection, pressure relief valves, and durable windings for high short-circuit resistance.

1000kVA Oil Immersed Transformer Technical Specifications
| Rated Power | 1000 kVA | |
| Rating Primary Voltage | 2.4 - 34.5kV | |
| Secondary Voltage | 480/277V 400/230V 380/220V Customized |
|
| Frequency | 50/60Hz | |
| Vector Group | Dyn11, Yyn0, Dyn5 | |
| Winding Material | Aluminum/Copper | |
| Efficiency | As IEEE, Doe 2016, CAS Std or Customized | |
| Impedance Voltage | Nominal 2% or Customized 1.1 - 5.75% | |
| Altitude | ≤1,000m or Customized | |
| Color | ANSI 70 Light gray/Munsell 7GY3.29/1.5 or customized, etc | |
| Tank material | Mild Steel, 304 Stainless Steel | |
| Insulating Oil Weight | 700 kg | |
| Total Weight | 3750 kg | |
| Outline Dimensions(L×W×H)in. | 2500 × 1500 × 2300(mm) | |
Oil Immersed Transformer Feature
Our 1000kVA oil-immersed transformer embodies reliability, engineering excellence, and enduring value. Every element - from the tank design to the core materials - reflects decades of technical expertise and field-tested innovation.
Built for heavy-duty industrial and utility environments, this transformer ensures continuous and stable power delivery even under the most demanding conditions. Its corrugated radiator tank provides exceptional heat dissipation, maintaining optimal performance during long-term operation and minimizing maintenance downtime. The conservator tank and breather system work together to regulate oil expansion and moisture control, extending insulation life and ensuring consistent operation over the years.
Precision-engineered high-voltage and low-voltage bushings deliver safe and efficient electrical connectivity, while the core and winding assembly are optimized to reduce energy losses and enhance mechanical strength. Every weld, joint, and seal is inspected to meet international standards - ensuring that what you receive is not just a transformer, but a long-lasting investment in performance and reliability.
Oil Filled Transformer applications
Power distribution: Used to reduce high voltages from the main power grid to lower voltages (e.g., 400V or 480V) for use in homes, buildings, and businesses.
Industrial facilities: Powers machinery, lighting, and other equipment in industrial parks, factories, mines, and chemical plants.
Commercial and urban infrastructure: Powers electrical systems in commercial buildings, high-rise buildings, airports, and subways.
Renewable energy: Used in the integration of renewable energy sources, such as solar or wind farms, by stepping up voltage for transmission to the grid.
Specialized environments: Can be used in specialized areas like petroleum chemical industries, drilling platforms, and nuclear power plants due to its robust and safe design.
How much load can a 1000 kVA transformer handle?
For a 1000kVA transformer, the maximum load depends on various factors such as the voltage rating, winding configuration, cooling system, and ambient temperature. Typically, a 1000kVA transformer can handle a maximum load of around 800-850kW.
How many Litres is a 1000 kVA transformer oil capacity?
In medium or large size distribution transformers that have power ratings of 100 to 1000 kVA and above 1000 kVA respectively, you might find anything from 200 liters to 1,500 liters or more. The same rule of bigger and more will apply for power transformers.
What is the power factor of a 1000kVA transformer?
Power factor refers to the ratio of active power to apparent power, generally expressed by cosφ. For example, a 1000kVA transformer, when the power factor cosφ=0.6, it can output 600kW of active power; but when the power factor cosφ=0.9, it can output 900kW of active power.
What is the purpose of oil in a transformer?
Transformer oil acts as a coolant, transferring heat away from the core and windings. By dissipating heat, the oil helps maintain optimal operating temperatures, preventing overheating and ensuring the transformer operates efficiently.
What is the impedance of a 1000 kVA transformer?
The impedance of 1000 kVA dry type transformers can range between 5% and 7%, which affects their voltage regulation and load handling capabilities. Oil-Immersed Transformers: Typically, oil-immersed transformers have lower impedance, usually around 4% to 6%.
company profile
GNEE New Material has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE New Material Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE New Material Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji