S11 Oil Immersed Power Transformer/Distribution Transformer
Apr 11, 2024
Leave a message
The company manufactures production of S11 - M series the whole sealing oil-immersed power transformer has the advantages of low loss, low noise, high efficiency, can obtain good energy saving effect and reduce pollution. Totally enclosed comparing with ordinary oil-immersed transformer, cancel the oil storage tank, the oil volume changed by corrugated tank elastic corrugated chips to automatically adjusting, transformer is isolated from the rest of the air, to prevent and slow the deterioration of oil and insulation aging, enhance the operation reliability.
Conditions of use
1. The highest temperature: + 40 ℃
2. The lowest temperature: -25 ℃
3. Altitude: < 4000 m
4. The highest monthly average relative humidity: 80% (20 ℃)
5. Installation location: without fire, explosion danger, serious foul, chemical corrosion, or violent vibration. Indoor And outdoor.

Product Standards
GB 1094 Power Transformer
GB/T 15164 Oil-immersed power transformer load guide
GB/T 6451 Three-phase oil-immersed power transformer technical parameters and requirements
IEC/60076
S11 type 6-11kV series main performance parameters of the products
| Type | Rated capacity (KVA) | Connection symbol | Voltage combination (KV) | No-load losses(W) | Load losses(W) | No- load current (%) | Short-circuit impedance (%) | ||
| H.V | Tapping range | L.V | |||||||
| S11 | 30 | Yyn0 or Dyn11 |
6 6.3 10 10.5 11 | ±5% or ±2×2.5% | 0.4 | 100 | 600 | 2.3 | 4.0 |
| S11 | 50 | 130 | 870 | 2.0 | |||||
| S11 | 63 | 150 | 1040 | 1.9 | |||||
| S11 | 80 | 180 | 1250 | 1.9 | |||||
| S11 | 100 | 200 | 1500 | 1.8 | |||||
| S11 | 125 | 240 | 1800 | 1.7 | |||||
| S11 | 160 | 280 | 2200 | 1.6 | |||||
| S11 | 200 | 340 | 2600 | 1.5 | |||||
| S11 | 250 | 400 | 3050 | 1.4 | |||||
| S11 | 315 | 480 | 3650 | 1.4 | |||||
| S11 | 400 | 570 | 4300 | 1.3 | |||||
| S11 | 500 | 680 | 5100 | 1.2 | |||||
| S11 | 630 | 810 | 6200 | 1.1 | 4.5 | ||||
| S11 | 800 | 980 | 7500 | 1.0 | |||||
| S11 | 1000 | 1150 | 10300 | 1.0 | |||||
| S11 | 1250 | 1360 | 12800 | 0.9 | |||||
| S11 | 1600 | 1640 | 14500 | 0.8 | |||||
| S11 | 2000 | 2280 | 17820 | 0.6 | 5.0 | ||||
| S11 | 2500 | 2700 | 20700 | 0.6 | |||||
S11 type 15-22 kv series main performance parameters of the products
| Type | Rated capacity (KVA) | Connection symbol | Voltage combination(KV) | No-load losses(W) | Load losses(W) | No- load current(%) | Short-circuit impedance (%) | ||
| H.V | Tapping range | L.V | |||||||
| S11 | 30 | Dyn11 | 15 20 22 |
±5% or ±2×2.5% | 0.4 | 90 | 660 | 2.1 | 5.5 |
| S11 | 50 | 130 | 960 | 2 | |||||
| S11 | 63 | 150 | 1145 | 1.9 | |||||
| S11 | 80 | 180 | 1370 | 1.8 | |||||
| S11 | 100 | 200 | 1650 | 1.6 | |||||
| S11 | 125 | 240 | 1980 | 1.5 | |||||
| S11 | 160 | 290 | 2420 | 1.4 | |||||
| S11 | 200 | 330 | 2860 | 1.3 | |||||
| S11 | 250 | 400 | 3350 | 1.2 | |||||
| S11 | 315 | 480 | 4010 | 1.1 | |||||
| S11 | 400 | 570 | 4730 | 1 | |||||
| S11 | 500 | 680 | 5660 | 1 | |||||
| S11 | 630 | 810 | 6820 | 0.9 | 6 | ||||
| S11 | 800 | 980 | 8250 | 1.8 | |||||
| S11 | 1000 | 1150 | 11330 | 0.7 | |||||
| S11 | 1250 | 1350 | 13200 | 0.7 | |||||
| S11 | 1600 | 1630 | 15950 | 0.6 | |||||
PRODUCT FEATURES
2.Key component-coil
Different structures (drum, foil, spiral, continuous) to meet the diverse needs of customers.
The end angle ring effectively improves the coil characteristics under impulse voltage-----voltage well-distributed.
There is an oil guide structure inside the coil to greatly reduce the temperature rise-----eliminate the risk of transformer short circuit.
Separate voltage regulating coil in the larger-capacity products to ensure the ampere-turn distribution in the core is well divided.
3.Key component-oil tank
The oil tank adopts barrel type or bell type - more stable structure.
The heat dissipation element adopts chip radiator-----better heat dissipation.
The wall of the tank is made directly by bending machine - strengthen tank's mechanical strength and effectively improve products appearance;
The edge of tank is sealed with oil-resistant rubber material, and there is sealing strip mark in the tank ----- prevent leakage.
Strict inspection of fluorescent leak test and pressure test-prevent leakage.
Oil immersed distribution transformer