Dry-type transformer manufacturer introduction Dry-type transformer is a common power equipment and is widely used in various fields. It has many advantages, but it also requires routine maintenance and care during use. The following dry-type transformer manufacturers will introduce it to you in detail.
dry transformer

Visual inspection. Check whether the shell is deformed, rusted, loose, etc., and repair and tighten it in time. Check whether the radiator is dusty or clogged, and clean and clear it in time. Check the fuel tank for oil leakage, oil stains, etc., and clean and repair it in time. Voltage check. Regularly measure the voltage on the primary side and secondary side of the dry-type transformer, record the data, and observe whether it is within the normal range. If abnormal voltage is found, timely inspection and adjustment should be carried out to ensure the normal operation of the transformer. Temperature check. Regularly measure the temperature of each part of the dry-type transformer and determine whether it is within the normal range according to the temperature indicator. If abnormal temperature is found, perform heat dissipation treatment in time to avoid overheating damage to the transformer. Fan check. Check whether the fan is running normally and whether there is any abnormal sound, and perform maintenance and cleaning according to the actual situation. If a fan failure is found, repair and replace it in time to ensure the normal operation of the transformer. Protective device inspection. Check that all grounding devices and safety protection devices are intact. If any abnormality in the protection device is found, repair and replace it in time to ensure the safe operation of the transformer. Maintenance cycle. Determine regular maintenance cycles and corresponding maintenance items based on frequency of use and actual conditions. It is generally recommended to conduct inspection and maintenance every three months to ensure the normal operation of the transformer. Note: When maintaining dry-type transformers, safety operating procedures should be followed to ensure personal safety. Corresponding records should be kept to provide reference for future maintenance.
The above is a brief introduction to you about the maintenance knowledge of dry-type transformers. For more knowledge, please continue to help our website.