Our company 's S9-M and S11 -M series of fully sealed oil-immersed power transformers feature low loss, low noise, and high efficiency, achieving excellent energy-saving effects and reducing pollution. Compared to ordinary oil-immersed transformers, fully sealed transformers eliminate the oil conservator; changes in oil volume are automatically adjusted and compensated for by the elasticity of the corrugated sheets in the corrugated tank. The transformer is isolated from air, preventing and slowing down oil deterioration and insulation aging, enhancing operational reliability, and requiring no maintenance during normal operation.
S11-M Series Oil-filled Transformer Technical Specifications:
1. Voltage levels : 6kV , 10kV
2. Voltage regulation method: no-load voltage regulation or on-load voltage regulation
3. Tap range: ± 5% , ± 2 x 2.5%
4. Capacity range: 30-2500kVA
5. Frequency: 50Hz , 60Hz
6. Number of phases: three-phase
7. Connector group label: Yyno or Dyn1
8. Impedance voltage: Meets national standards or user requirements.
9. Operating Environment: Maximum outdoor temperature not exceeding 40 ℃, minimum outdoor temperature -40 ℃ ( please specify when ordering ).
10. Cooling method: Oil immersion self-cooling
Installation location:
Oil-type transformers are suitable for power systems, industrial and mining enterprises, transportation, post and telecommunications departments, scientific research units, etc., and should be installed in places without fire, explosion hazards, severe pollution, chemical corrosion and violent vibration, indoors or outdoors.
parameters of S11 type 10kV double winding series oil transformer:
|
model |
Rated capacity (KVA) |
Connection group label |
Voltage combination (kV) |
No-load loss (W) |
Load loss (W) |
No-load current (%) |
Short-circuit withstand (%) |
||
|
high pressure |
Tap range |
low pressure |
|||||||
|
S11-M-30KVA |
30 |
Yyn0 |
6 |
±5% |
0.4 |
100 |
600 |
2.3 |
4.0 |
|
S11-M-50KVA |
50 |
130 |
870 |
2.0 |
|||||
|
S11-M-63KVA |
63 |
150 |
1040 |
1.9 |
|||||
|
S11-M-80KVA |
80 |
180 |
1250 |
1.9 |
|||||
|
S11-M-100KVA |
100 |
200 |
1500 |
1.8 |
|||||
|
S11-M-125KVA |
125 |
240 |
1800 |
1.7 |
|||||
|
S11-M-160KVA |
160 |
280 |
2200 |
1.6 |
|||||
|
S11-M-200KVA |
200 |
340 |
2600 |
1.5 |
|||||
|
S11-M-250KVA |
250 |
400 |
3050 |
1.4 |
|||||
|
S11-M-315KVA |
315 |
480 |
3650 |
1.4 |
|||||
|
S11-M-400KVA |
400 |
570 |
4300 |
1.3 |
|||||
|
S11-M-500KVA |
500 |
680 |
5100 |
1.2 |
|||||
|
S11-M-630KVA |
630 |
810 |
6200 |
1.1 |
4.5 |
||||
|
S11-M-800KVA |
800 |
980 |
7500 |
1.0 |
|||||
|
S11-M-1000KVA |
1000 |
1150 |
10300 |
1.0 |
|||||
|
S11-M-1250KVA |
1250 |
1360 |
12800 |
0.9 |
|||||
|
S11-M-1600KVA |
1600 |
1640 |
14500 |
0.8 |
|||||
|
S11-M-2000KVA |
2000 |
2280 |
17820 |
0.6 |
5.0 |
||||
|
S11-M-2500KVA |
2500 |
2700 |
20700 |
0.6 |
|||||
Note 1: Transformers with high voltage winding voltages of 10.5KV and 11KV can be provided according to user needs .
Note 2: A 0.69kV transformer can be provided upon request.
The main performance accommodation of transformer
• Impedance voltage
• No-load current
• No-load loss
• Short-circuit loss
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji