750 KVA 13.8 KV oil type distribution transformer
Nov 10, 2025
Leave a message
introduction of 750 KVA 13.8 KV oil type distribution transformer
A 750 kVA, 13.8 kV oil-type transformer is a three-phase distribution transformer that steps down the voltage from 13.8 kV to a lower level, using insulating oil for cooling and electrical insulation. It is designed for power distribution systems, often featuring a high-quality design with features like a silicon-steel iron core, copper windings, and advanced cooling systems to ensure high efficiency and reliability. Key components include a tank to hold the oil, a high-voltage winding, a low-voltage winding, and sometimes a tap changer for voltage regulation.
Our 750 KVA power transformer was designed with advanced technology and adopts high quality material and components which result in reliable quality and long operation time.
Oil filled Transformer Technical Specification
750 KVA Oil Immersed distribution Transformer to Guyana
|
Model |
S-M-750 kVA-13.8/0.48kV |
|
Type |
Oil type distribution transformer without conservator , bushings on top |
|
Standard |
IEC60076 |
|
Rated Power |
750 kVA |
|
Frequency |
60 HZ |
|
Phase |
Three |
|
Cooling Type |
ONAN |
|
Primary Voltage |
13.8 kV |
|
Secondary Voltage |
0.48 kV |
|
Winding Material |
Copper |
|
Vector Group |
Dny11 |
|
Impedance |
5.12% |
|
Tap Changer |
NLTC |
|
Tapping Range |
±2*2.5% |
|
No Load Loss |
1.4KW |
|
On Load Loss |
7.6KW |
|
Accessories |
Standard Configuration |
|
Remarks |
N/A |


Basic technical requirements for installation of transformer:
1. The transformer's high-voltage down lead and high-voltage bus must adopt copper core or aluminum core rubber insulated wire;
2. The different phase to phase distance of high-voltage bus, high-voltage down lead and drop out fuse must be less than 300 mm;
3. The distance between the low-voltage side line and the high-voltage down lead shall not be less than 150 mm;
4. It is strictly prohibited that the low-voltage line passes through the high-voltage down lead, and the sag of the lead up and down lead should be neat and consistent;
5. The transformer shell, circuit breaker, arrester ground wire and transformer low-voltage side zero line should be grounded together first;
6. The transformer platform should be kept horizontal and the height difference of diagonal line of the table should be less than 30mm.
What is the oil capacity of a 750 kVA transformer?
The oil capacity of a 750 kVA transformer generally ranges from 600 to 800 liters. The precise capacity will depend on the transformer's design and manufacturer specifications.
What is the minimum BDV for transformer oil?
30 KV
As per IEC, the minimum breakdown voltage of transformer oil should be not less than 30 KV. The BDV of transformer oil does not depend on the voltage rating of the transformer. Minimum transformer BDV value for either 11 KV, 22 KV, 132 KV is the same. The minimum transformer oil BDV is 30 KV.
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji