Why Choose a 200kVA Fluid-Immersed Transformer
A 200 kVA fluid-immersed (oil-filled) transformer is a widely used distribution unit for projects that need reliable continuous operation outdoors, such as industrial plants, utility feeders, and infrastructure sites. The insulating liquid provides both dielectric strength and efficient heat removal, so the transformer maintains a stable temperature rise under sustained load and tolerates harsh ambient conditions.
Key Technical Parameters
| Item | Specification |
|---|---|
| Rated capacity | 200 kVA |
| Type | Fluid-immersed (oil-filled) |
| Phase | Three-phase |
| HV voltage | 6 / 10 / 11 / 20 / 33 kV (customizable) |
| LV voltage | 400 / 415 / 433 V |
| Cooling method | ONAN |
| Frequency | 50 / 60 Hz |
| Vector group | Dyn11 / Yyn0 |
| Winding material | Copper or aluminum |
| Fluid type | Mineral oil (IEC 60296) or eco-friendly ester fluid |
| Installation | Outdoor, ground-mounted |
Construction and Performance Advantages
High-efficiency silicon steel core with stepped lap joints for low no-load loss.
Copper or aluminum windings with balanced ampere-turns and high short-circuit strength.
Fully sealed tank minimizes oxygen and moisture ingress.
Stable temperature rise under continuous full-load operation.
Bulk Procurement Considerations
When purchasing multiple units, technical consistency between batches is the main risk. Key control points include: a single agreed technical specification and drawing set; sample testing and first-article inspection; routine test reports for every unit (winding resistance, ratio, no-load and load loss, dielectric tests); and packaging suitable for sea freight, such as wooden cases with desiccant and shock protection. Agree on the acceptance standard (IEC 60076) and the sampling plan before production starts.
Application Scenarios
Typical projects include power distribution networks, manufacturing plants and industrial zones, oil and gas facilities, infrastructure and construction sites, and renewable energy systems such as solar and wind substations. Standardized specifications simplify installation and spare-part management across a project portfolio.
Standards Compliance
The transformer can be designed and tested to IEC 60076, ANSI/IEEE C57, GB/DL, or BS/EN requirements, depending on the destination market. Material certificates, test reports, and declarations of conformity support local regulatory acceptance.
Factory Quality Assurance and Acceptance
A factory-direct supply chain lets the buyer audit the production process from core lamination and winding to oil filling and final testing. Routine testing per IEC 60076 is performed on every unit; type tests such as temperature rise and lightning impulse are conducted on representative units. Documented quality control, together with professional export packaging and logistics, reduces the risk of damage and non-conformance in large-scale deployments.
FAQ
What is the difference between fluid-immersed and dry-type transformers at 200 kVA?
Fluid-immersed transformers use oil or ester liquid for cooling and insulation, offering higher overload capacity and outdoor suitability; dry-type transformers are used indoors where fire codes restrict flammable liquids.
Can the LV voltage be set to 415 V or 433 V?
Yes. LV ratings of 400 V, 415 V, and 433 V are common options, selected according to the local grid standard, for example 415 V in the UK and 433 V for some legacy networks.
How do I verify consistent quality across a bulk order?
Require a fixed technical specification, first-article inspection, routine test reports for each unit per IEC 60076, and a factory acceptance test before shipment.
What oil types are available?
Mineral insulating oil per IEC 60296 is standard; biodegradable ester fluids can be specified where environmental protection requirements are strict.
What packaging is used for export?
Units are normally packed in wooden cases or open crates with waterproof wrapping, desiccant, and securing brackets for container loading.