1250kVA 11kv Oil Immersed Distribution Transformer

Nov 06, 2025

Leave a message

1250kVA 11kv Oil Immersed Distribution Transformer

Features of 1250kVA 11kv Oil Immersed Distribution Transformer

The three-phase oil Immersed distribution transformer applies new type insulating structure and make the short-circuit resistance strong. The Iron core is made of high quality cold rolled silicon steel plate. High -voltage winding groups is made up of high quality oxygen free copper lines and it adopts multi drum type structure.


Reliable Structure

With the fundament of traditional frames and proved techniques our company made a great improvement for instance. We employ spiral loops with longitudinal oil path to produce a better cooling effect. We improve the effectual support of the loop's terminal face to strengthen the anti-short circuit electricity capability.


Excellent Materials

We use Oxygen free cooper lines of lower resistivity, which will become smoother and burr free after series of additional treatment so the load loss of our transformer is lower and the electric performance is better. We also use high quality silicon steel plate and high quality wooden laminating insulation pieces, and also we use thoroughly filtrated transformer oil and high quality rubber sealing material. All raw materials have passed the quality testing with national standard ISO90000 inspection.

Good Technology and Economic Performance
Compare with previous products, S9 and above series reduces the no load loss by 10%, and load loss by 24%, and no load electric current by 46%, as a result, the operating cost will drop by 19%.


Technical data sheet of 11KV S9,S9-M oil immersed distribution transformer


Rated capacity(KVA)
Voltage Ratio Connection group Impedance Losses No load current (%) Weight
Dimension (LXBXH)
High voltage Low voltage No load Load Active part Oil Gross
5







11
10.5
10
6.3
6









0.4
0.69









Yyn0
Dyn11









4%
0.07 0.35 4 50 45 145 550*450*800
10 0.09 0.40 3.5 70 55 185 550*450*800
20 0.11 0.52 3.0 110 60 235 660*505*850
30 0.13 0.63/0.6 2.3 130 65 265 660*530*870
50 0.17 0.91/0.87 2.0 195 80 365 740*600*930
63 0.20 1.09/1.04 1.9 230 80 400 720*620*100
80 0.25 1.31/1.25 1.9 260 95 460 770*640*1030
100 0.29 1.58/1.5 1.8 300 95 510 820*710*970
125 0.34 1.89/1.8 1.7 335 115 585 1040*680*1080
160 0.40 2.31/2.2 1.6 405 130 685 1090*670*1130
200 0.48 2.73/2.6 1.5 490 150 810 1160*760*1090
250 0.56 3.2/3.05 1.4 565 170 835 1215*775*1180
315 0.67 3.83/3.65 1.4 655 200 1095 1345*890*1205
400 0.80 4.52/4.3 1.3 840 250 1385 1450*935*1240
500 0.96 5.41/5.15 1.2 935 235 1505 1410*970*1290
630


4.5%
1.20 6.2 1.1 1100 330 1830 1595*1040*1315
800 1.40 7.5 1.0 1360 370 2225 1765*1170*1350
1000 1.70 10.3 1.0 1455 475 2555 1855*1255*1490
1250 1.95 12.0 0.9 1715 545 3140 1885*1270*1590
1600 2.40 14.5 0.8 2095 630 3680 1950*1620*2020
2000 2.80 19.8 0.8 2340 715 4190 2060*1740*2050
2500 3.30 23.0 0.7 2920 830 5100 2250*1800*2100
Note: Tapping range of high voltage : ±5%,±2*2.5%; Frequency 50Hz

 

 

Oil Filled Distribution Transformer application

  • Industrial facilities (manufacturing plants, refineries) needing to power heavy machinery.
  • Commercial complexes (malls, hotels, office towers) with high-density electrical demands.
  • Municipal or utility projects (substation upgrades, residential area 配电) requiring medium-to-low voltage conversion.

 

 

Customization Optional

1250kVA Oil Immersed Transformer

GNEE's 1250kVA oil-immersed transformers offer a variety of optional specifications to meet the needs of different customers. The rated voltage of the transformer can be customized according to customer requirements, with common high-voltage and low-voltage combinations to adapt to different power transmission environments. In order to improve efficiency and safety, the transformer is equipped with an adjustable temperature control device to ensure its stable operation under various working conditions. The oil tank is made of high-strength steel, which has excellent corrosion resistance and pressure resistance, ensuring durability in long-term use. The optional temperature protection system and overload protection device can cut off the circuit in time when the equipment is abnormal to prevent damage.

 

Customers can also choose different types of cooling methods, such as natural air cooling and forced air cooling, to adapt to different ambient temperature requirements. The insulation system of the transformer is made of high-quality materials, which can effectively improve its short-circuit resistance and service life. In addition, an intelligent monitoring system can be configured according to needs to monitor the operating status of the equipment in real time, provide early warning information, and ensure the safe operation of the equipment.

 

 

company profile


 

GNEE TRANSFORMER has strong production capacity and an efficient marketing team.

 

Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,

 

Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.

 

GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.

 

transformer Workshop equipment display


 

Transformer Test equipment
Test equipment
Transformer Test equipment2
Test equipment

 

Oil transformation workshop
Oil transformation workshop
Dry transformation workshop
Dry transformation workshop

 

Transformer Intelligent automatic bending machine
Intelligent automatic bending machine
Transformer Cnc punch press
Cnc punch press

 

Transformer Intelligent laser cutting machine
Intelligent laser cutting machine
Transformer Welding robot
Welding robot

 

Transformer Fully automatic laminating unit
Fully automatic laminating unit
Transformer Fully automatic laminating unit2
Fully automatic laminating unit

 

Transformer Wire winding unit
Wire winding unit
Transformer Wire winding unit2
Wire winding unit
Transformer Wire winding unit3
Wire winding unit

 

 

 

 

types of transformer from GNEE


 

500kV oil-immersed single-phase double-winding unexcited voltage regulating power transformer

500kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
220kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
66kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
66kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
35kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
35kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
10kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
S(B)H15(21~25)-M sealed amorphous alloy power transformer
SCB three-dimensional core transformer
35kV dry-type non-excitation voltage regulating power transformer
35kV dry-type on-load voltage regulating power transformer
35kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side without excitation voltage regulation
20kV dry-type non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side
SC(B)H15(17~19) amorphous alloy dry type transformer
SG(B)12~18 non-encapsulated H-class dry type transformer
CSD marine transformer
SGB three-dimensional core transformer
New energy transformer
35kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
10kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
Prefabricated cabin substation
Integrated inverter and step-up converter
10000V mine transformer
6000V mine transformer
Buried transformer
Phase-shifting rectifier transformer
Electric furnace transformer
Grounding transformer
QSG/SG three-phase dry isolation transformer
Three-phase pad-mounted transformer
Single-phase pad-mounted transformer
Single-phase pole-mounted transformer

Get Transformer Order specification

GNEE Transformer Order specification

When choosing our company's products, please provide the following data to better serve you.

Demander

Demander:

Telephonemethods:

Fax:

Project technical leader:

Telephonemethods:

Mailbox:

Transformer type selection

□Dry transformer

{□SC(B) Epoxy resin □SC(B) Non-encapsulated}

□American Box(ZGS)

{□Terminal type(-Z-) □Ring network type(-H-)}

□European Box change(YBM){□ Dry change □Oil change}

□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow}

□Amorphous alloy transformer{□Dry amorphous □ Oil amorphous}

□ Special transformer{Rectifier, Furnace, Mine, Etc}

Transformer basic data selection

Country of use:

 

Phase number:

□Three-phase(S conventional) □ Monophase □Other( )

Frequency:

□50Hz(conventional) □60Hz □ Other( )

Transformer oil:

□#25(conventional) □#45(minimum temperature below-25℃)

Rated capacity:

□( )kVA Conditions of use □Outdoor type □Indoor type

Altitude:

□Less than 1000m(conventional) □1000-2000m □3000m以上 over

Rated voltage(High voltage)

□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( )

Rated voltage(Low pressure)

□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( )

Connected group

□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( )

Impedance(%):

□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( )

Voltage regulation mode

□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z)

Voltage regulation range

□±2*2.5% □±5% □±3*2.5% □Other( )

Transformer accessory selection

□Fan □Temperature control{□ Common □With 485 computer interface}

□Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel}

□Protection level of dry case(□IP20(Conventional) □IP( )}

□Dry case height requirements{□None □Requirements[ ]}

□ Cable out mode of the dry variable shell

{□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]}

Note:

1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged

2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee)

Other special requirements(additional charges apply below)

Dry transformer

□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo

□Zero sequence transformer □Copper bar to the low voltage cabinet

□Protective mesh □Lighting □100kVA or less Fan □Shock absorber

Oil-immersed transformer

□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator

□400kVA and below low voltage outlet OABC phase with wiring terminals

□630kVA or below requires temperature control

□800kVA or below Low voltage outlet phase 0 requires wiring terminals

□630kVA and below must be equipped with gas relay

 

GNEE TRANSFORMER Industrial Layout


 

Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan

 

Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa

 

North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica

 

Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom

 

South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile

 

Middle East: The Middle East region

 

Oceania: Australia, Papua New Guinea. Fiji

Send Inquiry