100KVA Three Phase Oil Transformer High Voltage Transformer
Oct 29, 2025
Leave a message
100KVA Three Phase Oil Transformer Introduction
A 100kVA three-phase oil transformer is a common choice for power distribution in a variety of locations, including residential areas, commercial centers, and industrial facilities. Its applications include general power distribution, lighting, and supplying power to electronic and electrical equipment, with its oil-immersed design making it suitable for harsh outdoor environments and efficient in high-voltage applications.
Applications
Power distribution: Used to step down voltage for power supply to buildings, neighborhoods, and commercial areas.
Industrial use: Powers machinery and equipment in factories, chemical plants, and other industrial settings.
Commercial areas: Supplies electricity to shopping centers, office buildings, and other commercial establishments.
Residential areas: Used for the distribution of power to homes and other residential properties.
Suburban areas and farmhouses: Provides power for a variety of needs in these locations.
Key features for these applications
- Oil-immersed design: The oil cooling provides efficient heat dissipation, and the sealed design can adapt to harsh outdoor environments. It also helps extend the transformer's life by preventing oxidation and aging of the oil.
- Robust construction: Built to withstand short-circuit forces, enhancing reliability in demanding applications.
- Efficiency: Oil-filled transformers are generally more efficient than dry-type transformers.
100KVA Oil Transformer
100KVA Oil type Transformer Specification
|
Rated Capacity |
Voltage Ratio |
Vector Group |
No-load Losses(kw) |
Inpedence |
|
100kva |
380v/3kv/6kv/11kv/33kv |
Dyn11/Yd11/Yyno |
0.2 |
4% |
|
200kva |
380v/3kv/6kv/11kv/33kv |
Dyn11/Yd11/Yyno |
0.34 |
4% |
|
315kva |
380v/3kv/6kv/11kv/33kv |
Dyn11/Yd11/Yyno |
0.42 |
4% |
|
500kva |
380v/3kv/6kv/11kv/33kv |
Dyn11/Yd11/Yyno |
0.6 |
4% |
|
1000kva |
380v/3kv/6kv/11kv/33kv |
Dyn11/Yd11/Yyno |
1.15 |
4.5% |
|
1250kva |
6kv/11kv/33kv |
Dyn11/Yd11/Yyno |
|
4.5% |
|
2500kva |
11kv/33kv |
Dyn11/Yd11/Yyno |
2.3 |
|
|
4000kva |
11kv/33kv |
Dyn11/Yd11/Yyno |
2.8 |
|
|
10mva |
11kv/33kv/69kv/110kv |
Dyn11/Yd11/Yyno |
|
|
|
40mva |
11kv/33kv/69kv/110kv |
Dyn11/Yd11/Yyno |
|
|
|
100mva |
11kv/33kv/69kv/110kv/220kv |
Dyn11/Yd11/Yyno |
|

company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji