100kVA Oil Filled Electrical Power Distribution Transformer

Oct 29, 2025

Leave a message

 

On load tap changer transformer plays an important role in power system.It can not only stabilize the load center voltage, but also connect the power grid, adjust load current, improve reactive power distribution etc.Its basic principle is to lead out several taps from the coil on one side of the transformer, and switch from one tap to another through OLTC, without cutting off the load current.So as to change the effective number of turns and achieve the purpose of voltage regulation.


On load voltage regulation technology of transformer is widely used in distribution system, and also in step-up transformer of power plant. At present, almost all the large capacity transformers in the power system adopt on load voltage regulators,It is also equipped with a perfect low-voltage distribution network structure and sufficient reactive power compensation capacity to ensure the safe operation of the power grid and meet the requirements of customers for power quality.

100kVA Oil Immersed Electrical Power Distribution Transformer
Oil Type Transformer
100kVA Oil Immersed Electrical Power Distribution Transformer
Oil Type Transformer

100kVA Oil Immersed Transformer features

1.No load voltage regulating transformer need to adjust the tap of high-voltage side only when the power is cut off,so as to change the ratio of the transformer to regulate the voltage at the low-voltage side.Its regulation range is small, generally within ± 5%, It can only be adjusted once or twice a year.Most transformers in power system are no-load tap transformers.

 

2.The on load tap changing transformer has a special switch, which can change the tap position without power off (with load).Its voltage regulation range is large, generally more than 15% or even up to 30%, and it can be adjusted automatically for several times a day.


3.No excitation voltage regulation refers to no-load voltage regulation,which can be adjusted only when the transformer is off.On load tap chaning transformer can change the voltage by changing the tap position when it is on running.

4.OLTC switch has the advantages of frequent on-off, no spark and long service life.The traditional trigger circuit of power electronic switch has the
problem of electrical isolation.The application of optical fiber communication technology to the medium and high voltage trigger control system
can effectively solve the problem of high and low voltage electrical isolation.

 

 

sz11 three phase oil immersed transformer series parameters

50kVA 100kVA 150kVA 200kVA 250kVA 300kVA 400kVA 450kVA 500kVA Oil Immersed Electrical Power Distribution Transformer
 

Oil filled Transformer Mechanical parameters

Rated capacity (kVA) H.V.
(kV)
Tapping range L.V. (kV) Vector group Loss(kW) No-load current (%) Impedance voltage (%) Weight (kg)
Load loss No-load loss oil Total
10 6,10,11 ±5% or ±2*2.5% 0.4 0.415 0.433 Dyn11
or
Yyn0
0.26 0.09 3.2 4 45 172
20 0.44 0.10 3.0 65 240
30 0.63 0.13 2.3 65 245
50 0.91 0.17 2.0 80 330
63 1.09 0.20 1.9 90 365
80 1.31 0.25 1.9 95 410
100 1.58 0.29 1.8 115 490
125 1.89 0.34 1.7 140 620
160 2.31 0.40 1.6 155 720
200 2.73 0.48 1.5 175 810
250 3.20 0.56 1.4 200 940
315 3.85 0.67 1.4 215 1090
400 4.52 0.80 1.3 240 1250
500 5.41 0.96 1.2 285 1460
630 6.20 1.20 1.1 4.5 345 1720
800 7.50 1.40 1.1 390 2050
1000 10.30 1.70 1.0 460 2430
1250 12.00 1.95 1.0 550 2850
1600 14.50 2.40 0.8 690 3600
2000 18.00 2.60 0.7 790 4300

 

Rated capacity(kVA) H.V. (kV) Tapping range L.V. (kV) Vector group Loss(kW) No-load current (%) Impedance voltage (%) Weight (kg)
Load loss No-load loss oil Total
30 15,20 ±5% or ±2*2.5% 0.4,0.415. 0.433 Dyn11
or
Yyn0
0.60 0.10 2.1 4 85 350
50 0.87 0.13 2.0 90 480
63 1.04 0.15 1.9 110 600
80 1.25 0.18 1.8 110 660
100 1.50 0.20 1.6 120 700
125 1.80 0.24 1.5 130 800
160 2.20 0.29 1.4 140 940
200 2.60 0.33 1.2 160 1130
250 3.05 0.40 1.2 180 1290
315 3.65 0.48 1.1 230 1400
400 4.30 0.57 1.0 250 1550
500 5.15 0.68 1.0 260 1780
630 6.20 0.81 0.9 4.5 320 2100
800 7.50 0.98 0.8 350 2560
1000 10.30 1.15 0.7 450 2800
1250 12.00 1.36 0.6 490 3200
1600 14.50 1.64 0.6 640 4000
2000 17.14 1.94 0.6 800 4900
2500 20.26 2.30 0.5 1180 6300

 

Rated capacity(kVA) H.V. (kV) Tapping range L.V. (kV) Vector group Loss(kW) No-load current (%) Impedance voltage (%) Weightb (kg)
Load loss No-load loss oil Total
50 30,33,35 ,38.5 ±5% or ±2*2.5% 0.4 0.415 0.433 Dyn11
Yyn0
Yd11
1.27 0.21 2.0 6.5 265 860
100 2.12 0.29 1.8 310 1150
125 2.50 0.34 1.7 320 1190
160 2.97 0.36 1.6 360 1230
200 3.50 0.43 1.5 390 1300
250 4.16 0.51 1.4 425 1480
315 5.01 0.61 1.4 460 1590
400 6.05 0.73 1.3 490 1760
500 7.28 0.86 1.2 540 2150
630 8.28 1.04 1.1 620 2380
800 9.90 1.23 1.0 780 2800
1000 12.15 1.44 1.0 850 3410
1250 14.67 1.76 0.9 950 3890
1600 17.55 2.12 0.8 1060 4620
2000 19.35 2.72 0.7 1195 5345
2500 20.70 3.20 0.6 1285 5960
3150 24.30 3.80 0.6 7 1470 6695
4000 28.80 4.52 0.5 1760 8350

 

Rated capacity(kVA) High voltage(kV) High voltage tapping range(%) Low voltage(kV) Vector Group symbol No-load Loss
(kW)
On-load Loss
(kW)
No-load Loss
(kW)
On-load Loss
(kW)
Short-circuit resistance
(%)
No-load Current
(%)
Model 11 Model 18    
3150 35
38.5
±2 × 2.5
±3 × 2.5
±4 × 2.5
6.3
10.5
Yd11 3.04 23.08 2.4 21.9 7 0.72
4000 3.62 27.36 2.9 25.9 0.72
5000 4.32 31.35 3.5 29.7 0.68
6300 5.25 35.06 4.2 33.3 8 0.68
8000 7.2 38.48 5.8 36.5 0.6
10000 8.7 45.32 7.0 43 0.6
12500 10.08 53.87 8.0 51.1 0.56
16000 12.16 65.84 9.7 62.5 0.54
20000 14.4 79.52 11.5 75.5 0.54
25000 17.02 94.05 13.6 89.6 10 0.45
31500 20.22 112.86 16.2 106.4 0.4

 

 

company profile


 

GNEE New Material has strong production capacity and an efficient marketing team.

 

Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,

 

Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.

 

GNEE New Material has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.

 

transformer Workshop equipment display


 

Transformer Test equipment
Test equipment
Transformer Test equipment2
Test equipment

 

Oil transformation workshop
Oil transformation workshop
Dry transformation workshop
Dry transformation workshop

 

Transformer Intelligent automatic bending machine
Intelligent automatic bending machine
Transformer Cnc punch press
Cnc punch press

 

Transformer Intelligent laser cutting machine
Intelligent laser cutting machine
Transformer Welding robot
Welding robot

 

Transformer Fully automatic laminating unit
Fully automatic laminating unit
Transformer Fully automatic laminating unit2
Fully automatic laminating unit

 

Transformer Wire winding unit
Wire winding unit
Transformer Wire winding unit2
Wire winding unit
Transformer Wire winding unit3
Wire winding unit

 

 

 

 

types of transformer from GNEE


 

500kV oil-immersed single-phase double-winding unexcited voltage regulating power transformer

500kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
330kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
220kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
220kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase three-winding unexcited voltage regulating power transformer
110kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
110kV oil-immersed three-phase three-winding on-load voltage regulating power transformer
66kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
66kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
35kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
35kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
10kV oil-immersed three-phase double-winding unexcited voltage regulating power transformer
10kV oil-immersed three-phase double-winding on-load voltage regulating power transformer
S(B)H15(21~25)-M sealed amorphous alloy power transformer
SCB three-dimensional core transformer
35kV dry-type non-excitation voltage regulating power transformer
35kV dry-type on-load voltage regulating power transformer
35kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side without excitation voltage regulation
20kV dry-type non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding non-excitation voltage regulating distribution transformer
10kV dry-type three-phase double-winding transformer for photovoltaic, wind power and energy storage on the new energy power generation side
SC(B)H15(17~19) amorphous alloy dry type transformer
SG(B)12~18 non-encapsulated H-class dry type transformer
CSD marine transformer
SGB three-dimensional core transformer
New energy transformer
35kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
10kV oil-immersed three-phase double-winding non-exciting voltage regulation new energy generation side for photovoltaic, wind power, energy storage transformers
Prefabricated cabin substation
Integrated inverter and step-up converter
10000V mine transformer
6000V mine transformer
Buried transformer
Phase-shifting rectifier transformer
Electric furnace transformer
Grounding transformer
QSG/SG three-phase dry isolation transformer
Three-phase pad-mounted transformer
Single-phase pad-mounted transformer
Single-phase pole-mounted transformer

Get Transformer Order specification

GNEE New Material Order specification

When choosing our company's products, please provide the following data to better serve you.

Demander

Demander:

Telephonemethods:

Fax:

Project technical leader:

Telephonemethods:

Mailbox:

Transformer type selection

□Dry transformer

{□SC(B) Epoxy resin □SC(B) Non-encapsulated}

□American Box(ZGS)

{□Terminal type(-Z-) □Ring network type(-H-)}

□European Box change(YBM){□ Dry change □Oil change}

□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow}

□Amorphous alloy transformer{□Dry amorphous □ Oil amorphous}

□ Special transformer{Rectifier, Furnace, Mine, Etc}

Transformer basic data selection

Country of use:

 

Phase number:

□Three-phase(S conventional) □ Monophase □Other( )

Frequency:

□50Hz(conventional) □60Hz □ Other( )

Transformer oil:

□#25(conventional) □#45(minimum temperature below-25℃)

Rated capacity:

□( )kVA Conditions of use □Outdoor type □Indoor type

Altitude:

□Less than 1000m(conventional) □1000-2000m □3000m以上 over

Rated voltage(High voltage)

□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( )

Rated voltage(Low pressure)

□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( )

Connected group

□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( )

Impedance(%):

□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( )

Voltage regulation mode

□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z)

Voltage regulation range

□±2*2.5% □±5% □±3*2.5% □Other( )

Transformer accessory selection

□Fan □Temperature control{□ Common □With 485 computer interface}

□Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel}

□Protection level of dry case(□IP20(Conventional) □IP( )}

□Dry case height requirements{□None □Requirements[ ]}

□ Cable out mode of the dry variable shell

{□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]}

Note:

1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged

2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee)

Other special requirements(additional charges apply below)

Dry transformer

□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo

□Zero sequence transformer □Copper bar to the low voltage cabinet

□Protective mesh □Lighting □100kVA or less Fan □Shock absorber

Oil-immersed transformer

□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator

□400kVA and below low voltage outlet OABC phase with wiring terminals

□630kVA or below requires temperature control

□800kVA or below Low voltage outlet phase 0 requires wiring terminals

□630kVA and below must be equipped with gas relay

 

GNEE New Material Industrial Layout


 

Asia:China, Philippines, Cambodia, Malaysia, Pakistan, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Saudi Arabia, Saudi Arabia, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan

 

Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa

 

North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica

 

Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom

 

South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Mexico, Uruguay, Chile

 

Middle East: The Middle East region

 

Oceania: Australia, Papua New Guinea. Fiji

Send Inquiry