100kVA 10kv Low Loss Oil-Immersed Power Transformer
Oct 29, 2025
Leave a message
A 100kVA oil-immersed power transformer is primarily used for power distribution in a variety of settings, including rural areas, commercial centers, and industrial facilities. Its applications include providing power for lighting and general consumption, supporting agricultural production, and enabling energy-saving reconstructions in urban and railway power grids. These transformers can be configured as single-phase or three-phase to meet different electrical loads.
100kVA 10kv Oil-Immersed Power Transformer Key applications
Residential and commercial use: Ideal for power distribution in suburban and commercial areas to supply electricity to buildings, lighting, and appliances.
Industrial facilities: Used in normal factories, industrial plants, and chemical plants to step down voltage for equipment and machinery.
Rural electrification: Well-suited for use in rural power grids, scattered villages, and farmhouses for general power and lighting.
Power grid upgrades: Can be used in energy-saving reconstruction projects for both urban and railway power grids.
Specialized infrastructure: Applied in various large-scale projects like power stations, waste incineration plants, and bridges.


100kVA 10kv Oil Type Transformer Structural Installation

100kVA 10kv Oil Type Transformer Technical Parameters
| Rated capacity (kVA) | High voltage(KV) | Voltage Combination | Connective group label | No-load loss(KW) | Load loss (KW) |
No-load current(%) | Short circuit impedance (%) | Weight (KG) | ||
| High pressure tap range | Low voltage(KV) | Weight of oil | Total weight | |||||||
| 30 | 20/10 | ±5*2.5% ±2*2.5% |
0.4 | Dyn11 | 0.09 | 0.66 | 2.1 | 5.5 | 180 | 420 |
| 50 | 0.13 | 0.96 | 2.0 | 150 | 495 | |||||
| 63 | 0.15 | 1.145 | 1.9 | 170 | 560 | |||||
| 80 | 0.18 | 1.37 | 1.8 | 190 | 635 | |||||
| 100 | 0.2 | 1.65 | 1.6 | 215 | 710 | |||||
| 125 | 0.24 | 1.98 | 1.5 | 250 | 840 | |||||
| 160 | 0.29 | 2.42 | 1.4 | 285 | 945 | |||||
| 200 | 0.33 | 2.86 | 1.3 | 340 | 1125 | |||||
| 250 | 0.4 | 3.35 | 1.2 | 390 | 1295 | |||||
| 315 | 0.48 | 4.01 | 1.1 | 445 | 1475 | |||||
| 400 | 0.57 | 4.73 | 1.0 | 515 | 1712 | |||||
| 500 | 0.68 | 5.66 | 1.0 | 6.0 | 460 | 1995 | ||||
| 630 | 0.81 | 6.82 | 0.9 | 565 | 2450 | |||||
| 800 | 0.98 | 8.25 | 0.9 | 635 | 2765 | |||||
| 1000 | 1.15 | 11.33 | 0.7 | 840 | 3650 | |||||
| 1250 | 1.35 | 13.2 | 0.7 | 970 | 4220 | |||||
| 1600 | 1.63 | 15.95 | 0.6 | 1105 | 4800 | |||||
| 2000 | 1.95 | 19.14 | 0.6 | 1205 | 5240 | |||||
| 2500 | 2.34 | 22.22 | 0.5 | 1300 | 5650 | |||||
In addition to saving energy, our line of oil-immersed transformers has an impressive array of features that enhance their overall performance. First, these transformers are designed to operate with minimal noise output. Noise reduction is achieved through advanced insulation materials and professional construction technology to ensure a quiet and comfortable working environment.
In addition, our fully sealed transformers are designed to prevent moisture and fire. By eliminating the need for oil storage tanks, we improve the overall safety and reliability of transformers. The elasticity of the corrugated plates in the tank compensates for changes in the amount of oil and prevents air contact, reducing the risk of oil deterioration and insulation aging. This innovative design not only improves the service life of the transformer, but also reduces the need for regular maintenance, thereby saving costs and improving operational efficiency.
By investing in our range of oil-immersed transformers, customers can rest assured that they are sourcing high quality products that meet the strictest industry standards. Our transformers are manufactured from the best materials and subjected to rigorous testing to ensure optimum performance and durability. We take pride in our commitment to delivering exceptional products that exceed our customers' expectations.
In short, our oil-immersed transformer series represents a breakthrough in energy efficient power transformation technology. With low loss, high efficiency, moisture and fire resistance, our transformers offer a wide range of benefits to businesses in a wide range of industries. By choosing our transformers, customers can achieve significant energy savings, reduce pollution, and enjoy greater reliability and operational efficiency. Experience the difference with our range of energy-efficient oil-immersed transformers - a reliable choice.
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji

