Rated Capacity:500 kVA
Voltage Ratio:11kV / 0.4kV (customizable)
Frequency:50Hz / 60Hz
Vector Group:Dyn11
Cooling Method:ONAN
Send Inquiry
Chat Now

Description

Technical Parameters

Henan Gnee New Material Co., ltd. is one of the leading manufacturers and suppliers of 500 kva three phase oil filled transformer in China, also supports customized service with low price. Welcome to buy discount 500 kva three phase oil filled transformer for sale here from our factory. If you have any enquiry about pricelist, please feel free to email us.

 

A 500 kVA three phase oil filled transformer is a medium-capacity distribution transformer designed to step down medium voltage (e.g., 11kV or 13.8kV) to low voltage (e.g., 400V or 415V) for end-user applications.

 

It consists of:

  • Magnetic core made of high-grade silicon steel
  • Primary and secondary windings (copper or aluminum)
  • Insulating oil for cooling and electrical insulation
  • Tank and radiators for heat dissipation

 

This type of transformer uses oil as both a coolant and insulating medium, ensuring efficient and safe operation.

 

product-552-314

 

This powerful image showcases our flagship product: the high-performance 500KVA oil immersed transformer. Engineered for durability and reliability in the most demanding industrial applications, this unit is the cornerstone of efficient power distribution.

 

The robust construction visible here is designed to deliver two critical advantages: Super Overload Capacity, which allows this 500KVA oil immersed transformer to handle significant power surges and peak demands without failure, and a Low-loss Design, achieved through high-quality core materials that minimize energy waste and significantly reduce operating costs over its lifespan.

 

Investing in this 500KVA oil immersed transformer guarantees a resilient and economical power solution for your project.

 

500KVA Oil Immersed Transformer Parameters

 

ated Capacity(kVA)

Voltage Combination

Vector group

No-load Loss(kW)

Load Loss(kW)

No-load Current(%)

Short-Circuit Impedance(%)

High Voltage(kV)

High Voltage Tapping Range(%)

Low Voltage(LV)

30

20

±2×2.5 or ±5

0.4

Dyn11 or Yan11 or
Yyn0

0.08

0.66/0.63

1.7

5.5

50

0.1

0.96/0.91

1.6

63

0.12

1.14/1.09

1.5

80

0.14

1.37/1.30

1.4

100

0.16

1.64/1.57

1.2

125

0.19

1.98/1.88

1.2

160

0.23

2.41/2.30

1.1

200

0.27

2.85/2.72

1

250

0.32

3.34/3.18

0.96

315

0.38

4.00/3.81

0.88

400

0.46

4.72/4.39

0.8

500

0.54

5.64/5.48

0.8

630

0.65

6.48

0.72

800

0.78

7.84

0.64

1000

0.92

10.7

0.56

6

1250

1.1

12.5

0.56

1600

1.33

15.1

0.48

2000

1.56

19.1

0.48

2500

1.87

22.2

0.4

 

500KVA Oil Immersed Transformer Production Line

 

product-578-426

Witness our meticulous 6-step production process for building a reliable 500KVA oil immersed transformer: Cutting Material, Precision Winding, Assembling, Vacuum Drying, Rigorous Testing, and the Finished Product.

 

Uncompromising quality is built into every 500KVA oil immersed transformer we produce, as illustrated by this detailed look at our manufacturing process.

 

  1. Each unit begins with precision Cutting Material to ensure exact specifications.
  2. The heart of the transformer is formed during the Winding stage, where skilled technicians craft the coils with meticulous care.
  3. Assembling brings all components together under strict quality controls.
  4. The critical Vacuum Drying phase removes all moisture, guaranteeing superior insulation integrity and long-term stability.
  5. Before shipment, every 500KVA oil immersed transformer undergoes rigorous Testing to validate all performance parameters, ensuring the Finished Product that reaches you is nothing short of exceptional.

 

This end-to-end control is what defines our 500KVA oil immersed transformer.

 

 

Key Features of 500 kVA Three Phase Oil Filled Transformer

 

High Efficiency and Low Loss Design

Our 500 kVA three phase oil filled transformer is designed with:

  • Low no-load loss core materials
  • Optimized winding structure
  • Reduced load loss for energy savings

 

Reliable ONAN Cooling System

Equipped with ONAN cooling:

  • Natural oil circulation
  • Natural air convection
  • No need for external power

This ensures stable thermal performance and long service life.

 

Durable and Robust Construction

  • High mechanical strength
  • Corrosion-resistant coating
  • Sealed tank design to prevent oil leakage

 

500 KVA Three Phase Oil Filled Distribution Transformer Partial Inspection

 

Certificate Verification:

Verify the 500 KVA Transformer's certification. If the certificate is older than two months, retest the insulation resistance to ensure it meets the required standards.

 

Insulation Testing:

For the 500 KVA Oil-filled Transformer, use a megohmmeter to test the insulation resistance and confirm the insulation's integrity. Additionally, perform a Dielectric Absorption Ratio (DAR) test to evaluate the overall condition of the 500 KVA Transformer's insulation.

 

Oil Level and Quality:

Check the oil level in the 500 KVA Transformer and ensure that the ventilation holes are unobstructed. There should be no signs of oil leakage. Sample the transformer oil and analyze its dielectric strength, moisture content, acidity, and perform a dissolved gas analysis (DGA) to detect potential issues such as overheating or arcing in the 500 KVA Transformer.

 

Insulation and Connections:

Inspect both high and low voltage bushings and associated wires in the 500 KVA Transformer for any signs of damage. Ensure that all screws and connections are tight and secure to prevent electrical faults. Use infrared thermography to detect hotspots at connection points, which may indicate loose connections or corrosion in the 500 KVA Transformer.

 

Tap Changers and Fuses:

Confirm that the tap changer in the 500 KVA Transformer is correctly set according to operational requirements. Inspect and clean the tap changer contacts and mechanism. Perform electrical tests to ensure the proper operation of the tap changer in the 500 KVA Transformer.

 

Lightning Protection and Grounding:

Inspect the lightning arrester for any signs of damage in the 500 KVA Transformer. Measure the grounding resistance to ensure it meets safety standards, and verify the integrity of the grounding connections and electrodes.

 

Cooling System:

Inspect the radiators and cooling fans of the 500 KVA Transformer to ensure they are clean and functioning properly. If the 500 KVA Transformer is equipped with an oil circulation pump, check its operation to ensure effective cooling.

 

Noise and Vibration:

Monitor the 500 KVA Transformer for any abnormal noise or vibration. Such signs may indicate internal problems that require immediate attention to ensure the safe operation of the transformer.

 

Why Choose GNEE for 500 kVA Three Phase Oil Filled Transformer

 

GNEE New Material is a trusted manufacturer offering:

  • Advanced production facilities and strict quality control
  • Global export experience across multiple regions
  • Flexible OEM/ODM customization services
  • Fast delivery and reliable logistics support
  • Professional technical consultation and after-sales service

We are committed to delivering high-quality transformer solutions that meet your project needs.

 

Conclusion: Choose 500 kVA Three Phase Oil Filled Transformer for Reliable Power Distribution

 

In conclusion, the 500 kVA three phase oil filled transformer is a highly efficient, durable, and cost-effective solution for stable power distribution. Its robust design, reliable cooling system, and wide range of applications make it an ideal choice for modern electrical systems.

Request A Quote

 

If you are looking for a dependable transformer supplier, GNEE New Material is ready to support your project. Contact us today for a customized solution and competitive quote-send your inquiry now and ensure reliable power for your business!

 

 

What is the output voltage of a 500kVA transformer?

The output voltage of the 500kVA transformer is different between single-phase and three-phase:

The three-phase output voltage is usually: 208V, 240V, 400V, 480V, 600V, 480Y/277V, 600Y/347V, etc.

 

How many amps can a 500 kVA transformer supply?

Here is the formula for converting the transformer capacity into the current. Single-phase is different from three phase.

Three-phase transformer: The rated capacity is divided by the rated voltage, then divided by 1.732, and then multiplied by 1000, which is the rated current A.

Therefore, if the 500 kVA transformer is three-phase 500kVA transformer, if the rated voltage is 480V, 500÷240÷1.732×1000=1202A

The rated voltage is different, and the calculated amps value is also different.

 

How much oil is in a 500 kVA transformer?

The content of oil in oil-immersed transformers is about 14%-20% of the total weight. There is about 214-306L transformer oil in the 500 kVA transformer.

 

How much is a 500kva transformer?

The price of an oil transformer and a dry transformer is different, and the price of a 500 kVA dry transformer is more expensive than a 500 kVA oil transformer.

The 500kva pad-mounted transformer price is about $10,000. If there are many requirements for accessories and different standards, the price will also vary.

500kva oil-immersed transformer, the higher the voltage level, the higher the price, usually $6060-1000.

The price of a 500kva cast resin dry-type transformer is about $9090-13600.

Hot Tags: 500 kva three phase oil filled transformer, China 500 kva three phase oil filled transformer manufacturers, suppliers, factory, 1000 kva oil filled transformer, 20kv Series Oil Immersed Distribution Transformer, oil immersed transformer, 20kv hermetically sealed oil filled transformer, hermetically sealed oil filled transformer, 20kv oil immersed current transformer

Send Inquiry