Scb13-2000kva Dry Type Transformer
Description
Technical Parameters
Henan Gnee New Material Co., ltd. is one of the leading manufacturers and suppliers of scb13-2000kva dry type transformer in China, also supports customized service with low price. Welcome to buy discount scb13-2000kva dry type transformer for sale here from our factory. If you have any enquiry about pricelist, please feel free to email us.
GNEE New Material dry transformer
Dry-type transformers are widely welcomed for their oil-free properties and reduced fire-resistance rating requirements for buildings. In some special environments, only dry type transformers can be used, such as "multi-storey or high-rise main building". Therefore, in many places where oil-immersed transformers are not allowed, such as underground and high-rise buildings, places with high fire requirements can be designed as dry transformers. At present, epoxy resin casting dry transformer overcomes the problems of low heat resistance and easy aging and cracking of insulation materials. With the continuous development of insulating materials and the improvement of material performance, the insulation thermal resistance level can reach H class, which is the technical index that oil-immersed transformers can not achieve. Secondly, compared with the traditional oil-immersed transformer, dry transformer has the advantages of oil resistance, fire resistance, dustproof, moisture-proof, small partial discharge.Insulated cylinders are placed between high and low voltage coils to increase electrical insulation and are supported and restrained by gaskets. The fasteners of the parts have anti-loosening properties.
cast resin dry type transformer

|
No. |
Conditions |
Units |
Parameter Values |
|
|
1 |
Rated Voltage |
kV |
10 |
|
|
2 |
Highest Operating Voltage |
kV |
12 |
|
|
3 |
System Neutral Point Earthing Mode |
Unearthed |
||
|
4 |
Rated Frequency |
Hz |
50 |
|
|
5 |
Pollution Grade |
d(Ⅲ) |
||
|
6 |
System Short Circuit Current Level (High Voltage Side) |
kA |
20 |
|
|
7 |
Ambient Temperature |
Maximum Daily Temperature |
℃ |
40 |
|
Minimum Daily Temperature |
-25 |
|||
|
Maximum Daily Temperature Difference |
K |
25 |
||
|
Average Temperature of the Hottest Month |
℃ |
30 |
||
|
Maximum Annual Average Temperature |
20 |
|||
|
8 |
Humidity |
Average Daily Relative Humidity |
% |
≤95 |
|
Average Monthly Relative Humidity |
≤90 |
|||
|
9 |
Altitude |
m |
≤1000 |
|
|
10 |
Solar Radiation Intensity |
W/cm2 |
0.1 |
|
|
11 |
Maximum Icing Thickness |
mm |
20 |
|
|
12 |
Maximum average wind speed: keeping in good conditions for 10min at 10m from the ground level |
m/s |
35 |
|
|
13 |
Earthquake Resistance |
Horizontal Ground Acceleration |
m/s2 |
2 |
|
Safety Coefficient of 3 Since Resonance Cycles |
≥1.67 |
|||
|
14 |
Installation Site |
Indoor |
||
|
Note 1: Values about temperatures in the table must be adjusted accordingly if the lowest ambient temperature is above -25℃. Note 2: Pollution grade diagram must be provided if the pollution grade is grade IV. |
||||
dry type transformer manufacturers

Characteristics of three phase dry type transformer in application:
Dry transformers work in the same way as other transformers, following the physics of voltage technology required to use electromagnetic coupling: when a current flows through a current in a wire, it creates a changing magnetic field or surrounding "magnetic field." The fluctuation of the wire around the magnetic field, and the current it generates in the wire. Therefore, there will be fluctuations in the magnetic field in the second and first lines, and the current will cause the flow in the second line. Electricity is through two conductors that have no physical contact with each other.
First, dry-type transformers have the advantage of being oil-free and bulky, which reduces the fire risk. Can reduce fire prevention investment, save the corresponding disaster prevention and civil construction investment. Moreover, because the dry transformer has no oil leakage problem, the maintenance work of the daily operation of the transformer is reduced. If the oil aging is not required regularly, there is no need to change the oil. This greatly reduces the cost of routine maintenance. Secondly, due to dry transformer without core operation, dry transformer room can reduce the height of the building, reduce the cost of civil engineering. According to the specification requirements, "the high and low voltage distribution devices of non-fuel and non-oil-immersed power transformers can be placed in the same room", we usually share the dry transformer with the low voltage distribution device or high voltage distribution device, cancel the independent transformer room, reduce the footprint and save the total cost of the project.
Hot Tags: scb13-2000kva dry type transformer, China scb13-2000kva dry type transformer manufacturers, suppliers, factory, 35kv dry type pad mounted transformer, dry type transformer manufacturers, 20KV Series Cast Resin Dry Type Transformer, 750 kva dry type transformers, 800 KVA Dry Type Transformer, 11kv dry transformer
Previous
Dry Type Distribution TransformerSend Inquiry