Description
Technical Parameters
Henan GNEE Electric Co., Ltd. is one of the leading manufacturers and suppliers of 1600 kva medium voltage dry type power transformer in China, also supports customized service with low price. Welcome to buy discount 1600 kva medium voltage dry type power transformer for sale here from our factory. If you have any enquiry about pricelist, please feel free to email us.
1600 KVA medium voltage dry type power transformer video
Advanced medium voltage dry type power transformer by GNEE
Low No - Load Loss
Utilizes 0.18mm thin high - permeability silicon steel sheets. With full - oblique joints and multi - step progressive technology, the dry type isolation transformer achieves low no - load loss.
Advanced Technology
The high - voltage coils of the dry resin transformer are produced using imported vacuum casting equipment. It features fully automatic online mixing, ensuring the cast coils are free of air bubbles and have low partial discharge.
Superior Performance
The dry type electrical transformer adopts simulation analysis of electric fields, temperature fields, and magnetic fields.
Energy - Saving and Environment - Friendly
With resin casting insulation encapsulation, it is resistant to corrosion, flame - retardant, and explosion - proof. The resin cast dry type transformer has low losses and low noise, being environmentally friendly and pollution - free.
Technical Data Sheet
| 500 KVA Dry Type Transformer specifications and data sheet | |
| Model | SCB10 -500 KVA-6.6/0.55KV |
| Type | resin cast dry type transformer |
| Standard | IEC60076 |
| Rated Power | 1600 KVA |
| Frequency | 50 HZ |
| Phase | Three |
| Cooling Type | AN/AF |
| Primary Voltage | 6.6 KV |
| Secondary Voltage | 0.55 KV |
| Winding Material | Aluminum |
| Vector Group | Dyn11 |
| Impedance | 4% |
| Tap Changer | NLTC |
| Tapping Range | ±2*2.5% |
| No Load Loss | 1.16 KW |
| On Load Loss | 4.88 KW |
| Accessories | Temperature controller, Cooling Fans |
| SC(B)10 - 100~2500/10 Epoxy Dry-type Transformer | Rated low voltage: 0.4 kV | Rated voltage: 10(10.5, 11, 6.6, 6.3, 6) kV | |||||||
| Tap range: ±2×2.5% etc. | Connection group: Dyn11 or Yyn0 | ||||||||
| Product Model | UK% | No - load LossP0(W) | Load Loss(75℃)Pk(W) | I0(%) | LPA(AN)dB | Rail Gauge m×n |
Main Body DimensionsL×B×H(mm) | Dimensions of Upper - outlet Enclosure (including Mounting Feet) | Dimensions of Side - outlet Enclosure (including Mounting Feet) |
| SC(B)10-200/10 | 4 | 400 | 1371 | 0.7 | 42 | 550×550 | 960×750×804 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-125/10 | 4 | 470 | 1616 | 0.7 | 43 | 550×550 | 960×750×804 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-160/10 | 4 | 540 | 1860 | 0.7 | 43 | 550×550 | 1040×750×859 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-200/10 | 4 | 620 | 2200 | 0.7 | 43 | 550×550 | 1040×750×874 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-250/10 | 4 | 720 | 2410 | 0.7 | 43 | 660×660 | 1090×860×856 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-315/10 | 4 | 880 | 3030 | 0.7 | 45 | 660×660 | 1100×860×923 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-400/10 | 4 | 975 | 3480 | 0.7 | 45 | 660×660 | 1120×860×913 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-500/10 | 4 | 1160 | 4260 | 0.6 | 46 | 660×660 | 1240×860×953 | 1700×1400×1600 | 1700×1400×2200 |
| SC(B)10-630/10 | 4 | 1340 | 5134 | 0.6 | 46 | 820×660 | 1360×860×956 | 1900×1500×1800 | 1900×1500×2200 |
| SC(B)10-630/10 | 6 | 1300 | 5200 | 0.6 | 48 | 820×660 | 1380×860×938 | 1900×1500×1800 | 1900×1500×2200 |
| SC(B)10-800/10 | 6 | 1520 | 6020 | 0.5 | 49 | 820×820 | 1450×1020×993 | 1900×1500×1800 | 1900×1500×2200 |
| SC(B)10-1000/10 | 6 | 1770 | 7090 | 0.4 | 50 | 820×820 | 1510×1020×1058 | 1900×1500×1800 | 1900×1500×2200 |
| SC(B)10-1250/10 | 6 | 2090 | 8460 | 0.4 | 51 | 820×820 | 1530×1020×1140 | 1900×1500×1800 | 1900×1500×2200 |
| SC(B)10-1600/10 | 6 | 2450 | 10240 | 0.3 | 51 | 820×1070 | 1560×1150×1223 | 2000×1600×2000 | 2000×1600×2200 |
| SC(B)10-2000/10 | 6 | 3050 | 12600 | 0.3 | 52 | 1070×1070 | 1580×1150×1273 | 2000×1600×2000 | 2000×1600×2200 |
| SC(B)10-2500/10 | 6 | 3600 | 15000 | 0.3 | 53 | 1070×1070 | 1700×1150×1383 | 2200×1600×2000 | 2200×1600×2200 |
| SC(B)10-1600/10 | 8 | 2450 | 11263 | 0.3 | 51 | 820×1070 | 1590×1150×1198 | 2000×1600×2000 | 2000×1600×2200 |
| SC(B)10-2000/10 | 8 | 3050 | 13882 | 0.3 | 52 | 1070×1070 | 1660×1150×1298 | 2000×1600×2000 | 2000×1600×2200 |
| SC(B)10-2500/10 | 8 | 3600 | 16414 | 0.3 | 53 | 1070×1070 | 1720×1150×1493 | 2200×1600×2000 | 2200×1600×2200 |
General arrangement drawing

Testing and Inspection Technologies
All dry cast resin transformers are subject to strict control over the production process and quality aspects. Prior to leaving the factory, they undergo rigorous testing and inspection in accordance with national standards and customized requirements of customers. This includes essential inspection items such as partial discharge tests, lightning impulse withstand tests, noise tests, and more. Our state-of-the-art testing and inspection equipment, along with a comprehensive inspection and detection system, ensure that our 1600 KVA medium voltage dry type power transformers are of the highest quality and meet the highest standards.

Product details

Which Area Needs A Medium Voltage Dry Type Power Transformer?
Areas such as industrial parks, shopping malls, office buildings, hospitals, and schools often need dry - type power transformers. These places require reliable power supply and have relatively high requirements for safety and environmental protection. Dry - type transformers are suitable for such occasions due to their advantages of fire - resistance, explosion - proof, and low noise.
Hot Tags: 1600 kva medium voltage dry type power transformer, China 1600 kva medium voltage dry type power transformer manufacturers, suppliers, factory, 800 KVAencapsulated dry type transformer, 2000kva encapsulated dry type transformer, cast resin type transformer, 3 MVA dry type power transformer, 11kv Dry Type Transformer, 2000kva three phase dry type transformer