10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers
video

10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers

Rated capacity:30-2500KVA
Voltage: 10KV
Safety fire protection.
Low operating cost.
Good moisture resistance.
Low loss.
Perfect temperature protection control system.
Send Inquiry
Chat Now

Description

Technical Parameters

Henan Gnee New Material Co., ltd. is one of the leading manufacturers and suppliers of 10kv epoxy resin cast dry-type transformer 30kva 50kva 80kva 100kva dry type electrical transformers in China, also supports customized service with low price. Welcome to buy discount 10kv epoxy resin cast dry-type transformer 30kva 50kva 80kva 100kva dry type electrical transformers for sale here from our factory. If you have any enquiry about pricelist, please feel free to email us.

 

 

Epoxy Resin Cast Dry-type Transformer Products Description

 

This dry-type transformer features advanced epoxy resin encapsulation, ensuring superior insulation and flame retardancy (UL 94 V-0 certified). Designed for 10KV grids, it operates efficiently across -40℃ to 130℃, ideal for renewable energy systems, industrial plants, and urban substations. With a compact, oil-free structure, it reduces space requirements by 30% and eliminates fire hazards, suitable for confined or high-risk areas. Low noise (<55dB) and corrosion-resistant design adapt to coastal or polluted environments. Customizable capacity (30-100KVA) and optional smart monitoring modules enhance grid integration. Compliant with IEC/CE standards, it offers 98% efficiency and a 30-year lifespan, delivering eco-friendly, low-maintenance power solutions for modern energy demands.

 

 

 

video

 

 

 

 

Products parameter

 

 

Rated Capacity

KVA

Voltage Combination(KV)

No-Load Loss(W)

Load loss(W)

Short-Circuit Impedance (%)

No-load Current (%)

Sound Level LpA (dB)

High Voltage

(KV)

Branching(%)

Low Voltage(KV)

30

6

6.3

6.6

10

10.5

11

±5%

(±2×2.5)

0.4

190

710

4.0

2.1

52

50

270

1000

2.1

52

80

370

1380

1.6

53

100

400

1570

1.6

53

125

470

1850

1.4

56

160

540

2130

1.4

56

200

620

2530

1.2

56

250

720

2760

1.2

56

315

880

3470

1.0

58

400

980

3990

1.0

58

500

1160

4880

1.0

60

630

1340

5880

1.0

60

630

1300

5960

6.0

0.8

60

800

1520

6960

0.8

62

1000

1770

8130

0.8

62

1250

2090

9690

0.8

63

1600

2450

11730

0.8

64

2000

3050

14450

0.7

64

2500

3600

17170

0.7

68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact now

 

 

 

10KV Epoxy Resin Cast Dry-Type Transformer Core Advantages

 

1.High-Voltage Safety & Fire/Explosion Resistance
• Full-Sealed Epoxy Resin Cast Insulation:
Maintains excellent insulation under 10KV high voltage without insulating oil, eliminating leakage, combustion, or explosion risks. Complies with UL 94 V-0 fire rating, ideal for hospitals, data centers, and safety-critical facilities.

 

2.Extreme Environment Adaptability
• Wide Temperature Range:
Operates stably from -40℃ to 130℃ without fan cooling, suitable for Arctic cold or high-heat environments like steel mills.
• Corrosion & Humidity Resistance: Fully sealed structure blocks salt spray, chemical gases, and 95% humidity (non-condensing), reducing failure rates by 70% in coastal or chemical plants.

 

3.Compact Design & Low Maintenance Costs
• 30% Smaller Footprint:
Oil-free design reduces weight by 20%, perfect for space-constrained areas like underground garages or high-rises.
• 40% Lower Maintenance Costs: No oil replacement or sludge cleanup; only routine inspections required, with lifecycle costs below oil-immersed transformers.

 

4.High Shock/Vibration Resistance
• Integrated Cast Structure:
Windings and core are solidified into a robust unit, tripling vibration resistance. Ideal for mines or construction sites, minimizing contact failures.

 

Maintenance Guide

1.Daily Checks
• Visual & Temperature Inspection:
Conduct daily visual inspections for cracks/discoloration. Monitor coil temperature with an infrared thermometer (normal ≤120℃).
• Abnormal Noise: Immediate shutdown if unusual noise or arcing sounds occur.

 

2.Quarterly Maintenance
• Cleaning & Ventilation: Wipe the epoxy shell with a dry cloth; clear dust from ventilation channels to prevent overheating.
• Terminal Tightening: Secure loose bolts to avoid increased contact resistance and localized heating.

 

3.Annual Professional Testing
• Insulation Resistance Test:
Measure winding-to-ground resistance using a megohmmeter (standard ≥300MΩ).
• Partial Discharge Test: Evaluate internal insulation integrity to ensure stability under high voltage.

 

4.Troubleshooting
• Overheat Alarm:
Power off immediately if temperature exceeds 130℃ and contact the manufacturer.
• Insulation Failure: Replace epoxy-cast components if breakdown traces or short circuits are detected.

 

We can also provide the following transformer products:
30-2500KVA/10KV Laminated core distribution transformer
30-2500KVA Power transformer
30-2500KVA Power transformer(Three-phase oil-immersed power transformer)
30-2500KVA/10KV Oil-immersed three-phase double-winding non-excited voltage regulating distribution transformer
30-2500KVA/10KV Epoxy resin cast dry-type transformer
30-2500KVA/10KV Three-phase resin cast insulated dry type power transformer
30-2500KVA Epoxy resin cast dry-type transformer
30-2500KVA/10KV Epoxy resin cast dry-type transformer
30-2500KVA Dry-type three-phase double-winding non-excited voltage regulating distribution transformer
30-2500KVA/10KV Dry-type three-phase double-winding non-excited voltage regulating distribution transformer
30-2500KVA Amorphous alloy dry-type transformer
30-3200KVA Rectifier transformer
6300-42200KVA Three-phase oil-immersed power transformer
800-31500KVA/35KV Oil-immersed power transformer
100-1600KVA Combined transformer
380V Communication Low Voltage Distribution Cabinet
Pre-assembled substation (European style) ,etc.

 

Contact now

 

 

 

about us

 

10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers

10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers

10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers

10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers

10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers

10KV Epoxy Resin Cast Dry-type Transformer 30KVA 50KVA 80KVA 100KVA Dry Type Electrical Transformers

 

 

 

FAQ

 

Q: What Are the Core Competitive Advantages of Your Company?

A: Experience and Scale: Since its establishment in 2008, our company has been focusing on the transformer field for 18 years. We have delivered over 50,000 units of equipment and served more than 2,000 customers globally.
R&D and Production: A team of 200 professionals with a 20,000㎡ modern production base covering three major locations in China: Shijiazhuang, Xingtai, and Anyang. This ensures full autonomy from raw materials to finished products.
Customization Capability: Supports the design of transformers ranging from 50kVA to 5000kVA. Customized solutions can be provided for special scenarios such as high altitude or extreme temperatures.

Q: How Do You Ensure Delivery Time and Quality?

A: Supply Chain Assurance: Leveraging the industrial cluster advantages of three factories, we maintain sufficient raw material inventory, enabling faster order response compared to the industry average by 30%.
Quality Control System: From the precision of core stacking (±0.5mm) to 200 inspection items before product delivery, we ensure that each device complies with international standards such as CE and IEC.

Q: What Is the Delivery Cycle for Standard Products? Will Custom Products Affect Delivery Time?

A: Standard Products: The typical delivery cycle is 15-30 working days (starting from the signing of the contract and receipt of the advance payment).
Custom Products: Delivery cycles may extend depending on specific requirements, usually requiring 30-60 working days. If special materials, non-standard designs, or international transportation are involved, the specific time will be negotiated between both parties.

Q: Does Your Company's Transformers Meet International Standards?

A: Certifications: Passed certifications including IEC 60076 (International Standard), GB/T 6451 (Chinese National Standard), SGS, CE, UL, etc.
Special Certifications: Non-crystalline alloy transformers meet the IEC 61786 (high-efficiency transformer) standard; pre-assembled substations comply with the IEC 62271-200 (pre-assembled substation) requirement.

Q: How to Choose the Appropriate Type of Transformer?

A: Energy Efficiency Priority: Select amorphous alloy or epoxy resin dry-type transformers.
High Load Scenarios: Oil-immersed transformers are preferable.
Complex Distribution Needs: Contact engineers to customize pre-assembled substation solutions.

 

Contact now

 

 

Hot Tags: 10kv epoxy resin cast dry-type transformer 30kva 50kva 80kva 100kva dry type electrical transformers, China 10kv epoxy resin cast dry-type transformer 30kva 50kva 80kva 100kva dry type electrical transformers manufacturers, suppliers, factory, 11kv cast resin dry type transformer, 10 0 4kv 3 Phase Step Up Dry Type Transformer, 1000 KVA cast coil dry type transformer, 50 KVA dry type transformer manufacturers, Class F Epoxy Resin Cast Dry Encapsulated Transformer, medium voltage dry type transformer

Send Inquiry