100 KVA VPI Dry Type Transformer
video

100 KVA VPI Dry Type Transformer

Gnee's 100 KVA VPI dry type transformer has a rated voltage of 10 KV and its rated capacity is 100 KVA.
Send Inquiry
Chat Now

Description

Technical Parameters

Henan GNEE Electric Co., Ltd. is one of the leading manufacturers and suppliers of 100 kva vpi dry type transformer in China, also supports customized service with low price. Welcome to buy discount 100 kva vpi dry type transformer for sale here from our factory. If you have any enquiry about pricelist, please feel free to email us.

 

Transformer Video

 

Product Introduction

Discover our premium dry-type power transformer, engineered to excel across diverse applications. Harnessing state-of-the-art technology, this eco-friendly dry type step down transformer delivers efficient power distribution and steadfast performance, setting a new standard in the industry. Its innovative low-noise electrical design minimizes operational disturbances, while robust anti-explosion features guarantee safety and long-term durability, making it a reliable choice for any environment.

Whether you require a pad-mounted transformer for resilient outdoor operation or an inverter voltage transformer for precise voltage regulation, our product line has you covered. From 10kV high-voltage transformers to 100 kVA models, we offer a comprehensive range of options tailored to meet your specific power distribution demands.

When it comes to quality, reliability, and top-tier performance, our dry-type power transformers stand unmatched. Reach out to us today to explore competitive pricing and experience our exceptional customer service. Let us help you find the perfect power solution for your needs.

 

Scope of Supply

Product: resin cast dry type transformer

Voltage level: up to 11 KV

Rating level: up to 2500 KVA

The three phase dry type transformer can be designed according to customer's requirements.

 

Technical data sheet

SC(B)12 - 100~2500/10 Epoxy Dry-Type Transformer
Rated Voltage: 10(10.5, 11, 6.6, 6.3, 6) kV
Connection Group: Dyn11 or Yyn0
Rated Low Voltage: 0.4 kV
Tap Range: ±2×2.5% etc.
Product Model UK% No - load Loss P0 (W) Load Loss (at 75℃) Pk (W) I0 (%) LPA(AN) dB Rail Gauge m×n Main Body Dimensions L×B×H (mm) Dimensions of Upper - outlet Enclosure (including Mounting Feet) Dimensions of Side - outlet Enclosure (including Mounting Feet)
SC(B)12 - 100/10 4 320 1371 0.7 42 550×550 960×750×810 1700×1400×1600 1700×1400×2200
SC(B)12 - 125/10 4 375 1616 0.7 43 550×550 960×750×810 1700×1400×1600 1700×1400×2200
SC(B)12 - 160/10 4 430 1860 0.7 43 550×550 1050×750×860 1700×1400×1600 1700×1400×2200
SC(B)12 - 200/10 4 495 2200 0.7 43 550×550 1060×750×880 1700×1400×1600 1700×1400×2200
SC(B)12 - 250/10 4 575 2410 0.7 43 660×660 1000×860×860 1700×1400×1600 1700×1400×2200
SC(B)12 - 315/10 4 705 3030 0.7 45 660×660 1030×860×996 1700×1400×1600 1700×1400×2200
SC(B)12 - 400/10 4 785 3480 0.7 45 660×660 1050×860×1041 1700×1400×1600 1700×1400×2200
SC(B)12 - 500/10 4 930 4260 0.6 46 660×660 1090×860×1190 1700×1400×1600 1700×1400×2200
SC(B)12 - 630/10 4 1070 5200 0.6 46 820×660 1170×860×1256 1900×1500×1800 1900×1500×2200
SC(B)12 - 630/10 6 1040 5200 0.6 48 820×660 1210×860×1123 1900×1500×1800 1900×1500×2200
SC(B)12 - 800/10 6 1215 6020 0.5 49 820×820 1230×1020×1161 1900×1500×1800 1900×1500×2200
SC(B)12 - 1000/10 6 1415 7090 0.4 50 820×820 1320×1020×1247 1900×1500×1800 1900×1500×2200
SC(B)12 - 1250/10 6 1670 8460 0.4 51 820×820 1420×1020×1133 1900×1500×1800 1900×1500×2200
SC(B)12 - 1600/10 6 1960 10240 0.3 51 820×1070 1490×1150×1398 2000×1600×2000 2000×1600×2200
SC(B)12 - 2000/10 6 2440 12600 0.3 52 1070×1070 1500×1150×1408 2000×1600×2000 2000×1600×2200
SC(B)12 - 2500/10 6 2880 15000 0.3 53 1070×1070 1570×1150×1483 2200×1600×2000 2200×1600×2200
SC(B)12 - 1600/10 8 1960 11263 0.3 51 820×1070 1530×1150×1350 2000×1600×2000 2000×1600×2200
SC(B)12 - 2000/10 8 2440 13882 0.3 52 1070×1070 1610×1150×1416 2000×1600×2000 2000×1600×2200
SC(B)12 - 2500/10 8 2880 16414 0.3 53 1070×1070 1720×1150×1508 2200×1600×2000 2200×1600×2200

 

General arrangement drawing

100 KVA VPI dry type transformer diagram drawing and size.

Cast coil transformer

 

100 KVA VPI Dry Type Transformer Manufacturing Process

Core

The core is made of high-quality grain-oriented silicon steel sheets with excellent magnetic conductivity. Employing a 45-degree full oblique step-lap joint process, and coated with a special moisture-proof and anti-rust coating on the surface, it effectively reduces no-load losses, no-load current, and noise levels. This advanced manufacturing approach not only optimizes the performance of the dry type step up transformer but also extends its lifespan by protecting against environmental factors, ensuring stable and quiet operation across various working conditions.

dry type step up transformer

 

High-voltage windings

The high-voltage windings are crafted from high-quality conductors. Long and short chopped glass fiber mats serve as reinforcing fillers, and the windings are cast using the world-class Heidrich vacuum casting system under vacuum conditions. This advanced manufacturing process effectively suppresses the occurrence of partial discharge, with the partial discharge quantity being less than 5 picocoulombs. This not only ensures the high reliability and stability of the 100 KVA VPI dry type transformer but also significantly extends its service life, making it an ideal choice for various power distribution applications.

100 KVA VPI dry type transformer

 

Low-voltage windings

The low-voltage windings are fabricated from high-quality foil conductors and wound on an automated coiling machine. The coiling machine utilizes the "Foil Wire Hydraulic Energy-saving Tension Coiling Device" technology, along with ±0.5mm high-precision detection and advanced argon arc welding techniques. These features play a crucial role in ensuring the superior quality of the coil winding, enabling consistent performance and enhanced reliability of the cast coil transformer.

SCB12 dry transformer

 

What is the purpose of using power transformers in electrical systems? Why are they not used in certain situations?

Purpose of Using Electric Transformers in Electrical Systems

Voltage Conversion: They step up or step down AC voltage for efficient power transmission and distribution. High - voltage transmission reduces losses, and low - voltage supply is safer and suitable for end - users.

Isolation and Protection: Provide electrical isolation to prevent interference and protect equipment from voltage surges, enhancing system safety.

Impedance Matching: In some circuits, like audio and communication systems, they help achieve maximum power transfer by matching impedance.

Situations Where Power Supply Transformers are Not Used

DC Systems: Power transformer and distribution transformers work with AC only, not DC, as they rely on electromagnetic induction from changing magnetic fields.

Simple Low - Power Circuits: In low - power devices with straightforward voltage requirements, like battery - operated calculators, dtr transformers are unnecessary.

High - Frequency Applications with Special Requirements: At extremely high frequencies, dry type distribution transformers may have complex behaviors due to parasitic effects, so other components or techniques are used.

Cost and Space - Constrained Situations: Electrical power transformers can be large, heavy, and expensive. When cost and size matter, and voltage needs can be met otherwise, they may not be chosen, such as in some portable electronics.

 

Contact now

 

 

Hot Tags: 100 kva vpi dry type transformer, China 100 kva vpi dry type transformer manufacturers, suppliers, factory, Class F Epoxy Resin Cast Dry Encapsulated Transformer, cast resin type transformer, 63 KVA medium voltage dry type transformers, medium voltage dry type transformer, 3 MVA single phase dry type transformer, dry type pad mounted transformers

Send Inquiry