10kV Oil-Immersed Transformer
Nov 11, 2025
Leave a message
introduction of 10kV Oil-Immersed Transformer
The S11/S13/S20/S22 Series power transformers are engineered for superior performance and durability in diverse applications, including industrial facilities and power substations. With advanced core and winding designs, these transformers deliver low energy loss, excellent cooling, and long service life.The corrugated tank design compensates for oil volume changes caused by temperature fluctuations, improving operational stability.The transformers are sealed to prevent oxygen and moisture ingress, ensuring optimal insulation and oil longevity.Safety features, including pressure release and gas relay options, enhance reliability for critical installations.

10kV Oil-Filled Transformer feature
High-Efficiency Core: The transformer core is made of high-permeability, grain-oriented cold-rolled silicon steel sheets. Featuring a new structure with fully mitered joints and stepped circular cross-sections, the core minimizes energy loss and noise.
Reliable Windings: The windings are designed with corrugated oil ducts and non-impregnated processes, secured with compression bands. High-voltage windings come with taps to adjust the voltage as required, with tap changers conveniently located on the tank lid for easy operation after power disconnection.
Safety Protection Devices: Models ranging from 30 to 2000kVA are equipped with pressure relief valves and optional gas relays with alarm and tripping terminals to enhance operational safety.
Advanced Oil Cooling System: The transformer features a corrugated wall tank with integrated cooling and "breathing" functions, eliminating the need for an oil conservator. The vacuum oil-filling process ensures no moisture or air contamination, enhancing the longevity of the AC transformer and reducing maintenance requirements.
Oil Transformer Product Parameters
| Items | Item |
| Production Descriptions | Oil-Immersed Transformer |
| Reference standards | IEC 60076-11 |
| Capacity | 50-2500kVA or Customized |
| Frequency | 60 / 50Hz |
| Voltage (HV) | 22KV or customized |
| Voltage (LV) | 0.4KV or customized |
| Impedance | 4% |
| Connections (Vector Group) | Dyn11 |
| Tapping Range | ±2×2.5% |
| Core materials | Silicon Steel |
| Winding materials | Aluminum or copper |
| Lightning Impulse Withstand Voltage | IEC standard |
| AC withstand voltage | IEC standard |
| Temperature Rise class | H-class |
| Temperature Rise | 125K |
| Cooling method | AN/AF |
| Delivery Capacity | 300 units per month |
Oil-Filled Transformer Operating Conditions
- Compatible with AC 50Hz/60Hz power systems operating up to 20kV.
- Suitable for industries like petroleum, metallurgy, and chemical plants, as well as dusty and challenging environments.
- Ideal for energy distribution in power substations, industrial facilities, and public infrastructure.
- Low maintenance requirements with no need for periodic oil sampling.
Case Studies and Real-World Applications
Case Study 1: Power Plant Efficiency Enhancement
In a large power plant, replacing outdated transformers with modern oil immersed units resulted in a 15% reduction in energy losses, highlighting their impact on efficiency and reliability.
Case Study 2: Industrial Reliability
An automotive manufacturing facility reported a 20% decrease in downtime after installing oil immersed transformers, attributing this improvement to enhanced thermal management and fault tolerance.
Innovations and Future Trends in Transformer Technology
The future of oil immersed transformers includes:
Smart Monitoring Systems: IoT-based sensors for real-time condition monitoring.
Eco-Friendly Oils: Increased use of biodegradable and sustainable oils.
Compact Designs: Advances in materials leading to smaller, more efficient transformers.
Emerging Technologies
Nanofluids: Incorporating nanoparticles into transformer oils to enhance thermal and dielectric properties.
Digital Twins: Simulating transformer performance to predict and mitigate issues proactively.
company profile
GNEE TRANSFORMER has strong production capacity and an efficient marketing team.
Our transformer products include 500kV, 400kV, 330kV, 220kV, and 110kV ultra-high voltage transformers, various dry-type transformers/oil immersed transformers/amorphous alloy transformers of 35kV and below, new energy transformers, and prefabricated substations,
Export series: single-phase transformer, three-phase transformer, cylindrical transformer, isolation transformer, control transformer, voltage regulator and other products, And various specifications of special transformers such as grounding transformers, arc suppression coils, Bitcoin transformers, prefabricated cabins, reactors, electric furnace transformers, rectifier transformers, mining transformers, marine transformers, etc.
GNEE TRANSFORMER has successively passed ISO9001, ISO14001, ISO45001, SA8000 system certification. At the same time, 10kV and 35KV level distribution transformers and box type substations have obtained interna- tional Electrotechnical Commission IEC certification, US UL certification, German TUV certification, EU CE certification, Dutch KEMA certification, and GOST certification. Our product sales cover the global market, including 72 countries and regions such as the United States, Europe, Canada, Mexico, etc.
transformer Workshop equipment display













types of transformer from GNEE
Get Transformer Order specification
GNEE Transformer Order specification
|
When choosing our company's products, please provide the following data to better serve you. |
||
|
Demander |
||
|
Demander: |
Telephonemethods: |
Fax: |
|
Project technical leader: |
Telephonemethods: |
Mailbox: |
|
Transformer type selection |
||
|
□Dry transformer {□SC(B) Epoxy resin □SC(B) Non-encapsulated} □American Box(ZGS) {□Terminal type(-Z-) □Ring network type(-H-)} □European Box change(YBM){□ Dry change □Oil change} |
□ Oil-immersed transformer{□ Fully sealed(-M-) □Oil-bearing pillow} □Amorphous alloy transformer{□Dry amorphous □ Oil amorphous} □ Special transformer{Rectifier, Furnace, Mine, Etc} |
|
Transformer basic data selection
|
Country of use: |
|
|
Phase number: |
□Three-phase(S conventional) □ Monophase □Other( ) |
|
Frequency: |
□50Hz(conventional) □60Hz □ Other( ) |
|
Transformer oil: |
□#25(conventional) □#45(minimum temperature below-25℃) |
|
Rated capacity: |
□( )kVA Conditions of use □Outdoor type □Indoor type |
|
Altitude: |
□Less than 1000m(conventional) □1000-2000m □3000m以上 over |
|
Rated voltage(High voltage) |
□6kV □10kV □20kV □35kV □66kV □110kV □220kV □Other( ) |
|
Rated voltage(Low pressure) |
□0.4kV □0.66kV □10kV □10.5kV □35kV □其他 Other( ) |
|
Connected group |
□Dyn11(conventional) □Yyn0 □YNd11 □li0(Single-phase) □Other( ) |
|
Impedance(%): |
□4% □4.5% □5.5% □6% □6.5% □7.5% □8% □Other( ) |
|
Voltage regulation mode |
□Voltage regulation without excitation(conventional) □On-load voltage regulation(Z) |
|
Voltage regulation range |
□±2*2.5% □±5% □±3*2.5% □Other( ) |
Transformer accessory selection
|
□Fan □Temperature control{□ Common □With 485 computer interface} □Dry case{□ Ordinary steel sheet □Aluminum alloy » Stainless steel} □Protection level of dry case(□IP20(Conventional) □IP( )} □Dry case height requirements{□None □Requirements[ ]} □ Cable out mode of the dry variable shell {□ Up-and-out □ Up-and-down □Down-in/DOWN-out □Down-in/UP-out □Down-in/DOWN-out □Down-in/ side-out [□Left □ Right-out]} |
|
Note: 1. (Dry change requirements s 100kVA transformer does not include fans, such as fans, need to be charged 2. (Oil changes <630kVA transformer does not include temperature control, gas relay, if necessary, need to increase the fee) |
Other special requirements(additional charges apply below)
|
Dry transformer |
□Shell and bottom plate{□Ordinary □Fully sealed} □Travel switch □Magnetic lo □Zero sequence transformer □Copper bar to the low voltage cabinet □Protective mesh □Lighting □100kVA or less Fan □Shock absorber |
|
Oil-immersed transformer |
□No.45 oil for non-low temperature areas □Designated brand on-load voltage regulator □400kVA and below low voltage outlet OABC phase with wiring terminals □630kVA or below requires temperature control □800kVA or below Low voltage outlet phase 0 requires wiring terminals □630kVA and below must be equipped with gas relay |
GNEE TRANSFORMER Industrial Layout
Asia:China, Philippines, Cambodia, Malaysia, Myanmar, Indonesia, Vietnam, Mongolia, Japan, Taiwan Province, Bangladesh, Sri Lanka, Lebanon, Saudi Arabia, Turkey, Armenia, Iraq, Iran, Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan
Africa:Egypt, Ethiopia, Angola, Botswana, Burundi, Cape Verde, Congo, Guinea, Ghana, Gabon, Zimbabwe, Cameroon, Kenya, Rwanda, Malawi, Mauritius, Mauritania, Mozambique, South Africa, Nigeria, Somalia, Chad, Central Africa
North America: Aruba, Panama, Dominican Republic, Costa Rica, Honduras, Caribbean region,Canada, United States, Mexico, El Salvador, Guatemala, Jamaica
Europe: Bulgaria, North Macedonia, Finland, Norway, Ukraine, Greece, Hungary, Italy, United Kingdom
South America: Argentina, Paraguay, Ecuador, Colombia, Guyana, Venezuela, Uruguay, Chile
Middle East: The Middle East region
Oceania: Australia, Papua New Guinea. Fiji

